Производитель: York
Размер: 622.08 kb
Название файла:
|
Фрагмент инструкции
This option is available to allow the installer the flexibility to install the coil at a later date without duct modifications. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 258931-BT G-A-0606 COOLING CAPACITY - Coil Only* Model Rated CFM Entering Air °F (Wet Bulb) MBH @ Evaporator Temperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW "A" TYPE 72 25.3 23.1 20.6 17.9 FC18A 675 67 23.4 21.1 18.7 16.1 PC18A 62 19.2 12.0 18.7 12.4 57 15.6 13.5 11.3 8.8 72 28.1 25.7 22.9 19.9 FC18B 850 67 26.0 23.5 20.8 17.9 PC18B 62 21.3 18.9 16.4 13.7 57 17.3 15.0 12.6 9.8 72 35.6 32.5 29.0 25.2 FC24A 675 67 32.9 29.7 26.3 22.7 PC24A 62 27.0 23.9 20.7 17.4 57 21.9 19.0 15.9 12.4 72 35.6 32.5 29.0 25.2 FC24B 850 67 32.9 29.7 26.3 22.7 PC24B 62 27.0 23.9 20.7 17.4 57 21.9 19.0 15.9 12.4 FC30A 72 38.9 35.4 31.6 27.6 PC30A 1025 67 33.9 30.3 26.8 23.0 FC30B 62 27.3 23.7 22.5 18.0 PC30B 57 22.6 20.1 17.5 14.8 FC35B 72 46.1 41.9 37.4 33.0 PC35B 1025 67 36.9 32.6 28.6 24.3 FC35C 62 28.9 24.2 26.4 19.7 PC35C 57 24.7 22.9 21.1 19.7 72 46.0 41.9 37.4 32.9 FC36A 1150 67 36.8 32.5 28.5 24.2 PC36A 62 28.8 24.1 26.4 19.6 57 24.7 22.9 21.1 19.6 FC36B 72 51.1 46.5 41.5 36.6 PC36B 1250 67 40.9 36.1 31.7 26.9 FC36C 62 32.0 26.8 29.3 21.8 PC36C 57 27.4 25.4 23.4 21.8 FC42B 72 86.6 74.5 62.0 49.0 PC42B 1400 67 69.4 58.2 47.4 36.3 FC42C 62 54.1 43.0 35.1 29.3 PC42C 57 46.5 40.7 35.1 29.3 72 99.4 85.5 71.2 56.2 FC48C 1620 67 79.6 66.8 54.4 41.6 PC48C 62 62.1 49.4 40.2 33.7 57 53.3 46.7 40.2 33.7 FC60C 72 118.7 100.0 81.1 61.5 PC60C 1850 67 95.0 78.4 61.9 45.4 FC60D 62 74.0 58.0 45.7 36.7 PC60D 57 63.6 54.8 45.7 36.7 * - See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity. 2 Unitary Products Group 258931-BTG-A-0606 COOLING CAPACITY - COIL ONLY* Model Coil Rated CFM Entering Air °F MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG (Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION 72 25.8 23.5 21.0 18.2 MC18A 550 67 23.7 21.5 19.0 16.4 62 19.5 17.3 14.9 12.6 57 15.8 13.5 11.5 9.0 72 28.7 26.1 23.3 20.2 MC18B 650 67 26.4 23.9 21.1 18.2 62 21.6 19.2 16.6 14.0 57 17.5 15.2 12.8 10.0 72 36.3 33.0 29.5 25.6 MC24A 850 67 33.4 30.2 26.7 23.1 MC24B 62 27.4 24.3 21.0 17.7 57 22.2 19.3 16.2 12.6 72 41.5 37.8 33.7 29.5 MC30A 1025 67 36.2 32.4 28.6 24.5 MC30B 62 29.1 25.3 24.0 19.2 57 24.1 21.5 18.7 15.8 72 46.9 42.7 38.2 33.6 MC35B 1025 67 37.6 33.2 29.1 24.7 MC35C 62 29.3 24.6 26.9 20.0 57 25.2 23.3 21.5 20.0 72 46.8 42.6 38.1 33.6 MC36A 1150 67 37.5 33.1 29.1 24.7 62 29.3 24.6 26.8 20.0 57 25.1 23.2 21.4 20.0 72 52.0 47.3 42.3 37.3 MC36B 1250 67 41.7 36.8 32.3 27.4 62 32.5 27.3 29.8 22.2 57 27.9 25.8 23.8 22.2 72 53.4 48.6 43.4 38.3 MC36C 1250 67 42.8 37.8 33.1 28.2 62 33.4 28.1 30.6 22.8 57 28.7 26.5 24.5 22.8 72 88.4 76.0 63.3 50.0 MC42B 1400 67 70.8 59.4 48.4 37.0 MC42C 62 55.2 43.9 35.8 29.9 57 47.4 41.5 35.8 29.9 72 100.5 86.4 72.0 56.8 MC48C 1650 67 80.4 67.5 55.0 42.1 MC48D 62 62.7 49.9 40.7 34.0 57 53.9 47.2 40.7 34.0 72 119.9 101.0 80.0 62.2 MC60D 1825 67 96.0 79.2 62.6 45.8 62 74.8 58.6 46.2 37.0 57 64.3 55.4 46.2 37.0 72 124.8 105.2 85.3 64.7 MC61D 2000 67 99.9 82.5 65.2 47.7 62 77.9 61.1 48.1 38.6 57 66.9 57.7 48.1 38.6 * See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity. Unitary Products Group 3 258931-BTG-A-0606 COOLING CAPACITY - Coil Only* MODEL RATED ENTERING AIR °F (Wet Bulb) MBH @ Evaporator Temperature and Corresponding Pressure °F/ PSIG CFM 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 HORIZONTAL DUCT TYPE 72 35.3 32.4 28.7 24.9 HD24A 815 67 32.6 29.4 26.0 22.5 62 26.7 23.7 20.5 17.2 57 21.7 18.8 15.7 12.3 72 57.9 52.7 47.1 41.5 HD36B 1192 67 46.4 41.1 35.9 30.4 62 36.2 30.4 26.5 24.7 57 31.1 28.7 26.5 24.7 72 83.4 71.7 59.7 47.1 HD48C 1610 67 66.8 56.1 45.6 34.9 62 52.1 41.5 33.7 28.3 57 44.7 39.2 33.7 28.3 72 133.0 112.4 90.9 69.2 HD60D 2100 67 106.5 87.9 69.4 50.0 62 83.0 65.0 51.3 41.1 57 71.2 61.4 51.3 41.1 * See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity. Notes: • MC coils available with a factory installed horizontal drain pan option (H). COOLING CAPACITY - COIL ONLY* Model Rated CFM Entering Air °F (Wet Bulb) MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE °F / PSIG 35/61.5 40/68.5 45/76.0 50/84.0 HC18A 600 72 26.4 24.0 21.5 18.6 67 24.3 22.0 19.4 16.8 62 20.0 17.7 15.3 12.9 57 16.1 14.0 11.8 9.2 HC30A 1000 72 42.7 38.9 34.7 30.6 67 34.3 30.3 26.5 22.5 62 26.7 22.5 24.5 19.8 57 22.9 21.2 19.6 18.3 HC36B 1200 72 73.4 63.1 52.5 41.5 67 58.8 49.3 40.2...
Эта инструкция также подходит к моделям:Насосное оборудование - FC (622.08 kb)
Насосное оборудование - HC (622.08 kb)
Насосное оборудование - HD (622.08 kb)
Насосное оборудование - MC (622.08 kb)