Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Metabo, модель Compressor Pump Classic 8

Производитель: Metabo
Размер: 574.22 kb
Название файла:
Язык инструкции:enesfrdenl
Перейти к скачиванию



Фрагмент инструкции


Do not stop the compressor by unplugging, but switch OFF using the switch. Unplug after use. 4.3 Generating compressed air 1. Start compressor (28) and wait until the max. tank pressure is reached (compressor shuts off). The tank pressure is indicated by the tank pressure gauge (32). 30 31 28 29 32 2. Set pressure regulator (29) to required working pressure. The current working pressure is indicated by the regulated pressure gauge (31). A Caution! The regulated pressure may not be set higher than the max. working pressure of the connected air tools! 3. Connect air hose to compressed air outlet (30). 4. Connect air tool. You are now ready to work with the air tool. 5. Switch the compressor OFF (28), if you do not continue working immediately afterwards. Unplug after switching OFF. 5. Care and Maintenance A Danger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the compressor has come to a complete stop. . Ensure the compressor and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. After all servicing: . Check to see that all safety devices are operational. . Make sure that no tools or other parts remain on or in the machine. Repair and maintenance work other than described in this section must only be carried out by qualified specialists. 5.1 Periodic maintenance A Caution! Uberprufen Sie am neuen Verdichter die Anzugsmomente der Zylinderkopfschrauben (siehe "Technische Daten") nach den ersten 50 und 250 Betriebsstunden. Prior to each use • Check air hoses for damage, replace if necessary. • Check all screwed connections for tightness, tighten if necessary. • Check power supply cable for damage, if necessary have replaced by a qualified electrician. Every 50 operating hours • Check air filter element (33) of compressor pump, clean if necessary. 33 •Check oil level of pump at oil sight glass (34), top up oil if necessary. 34 •Drain condensate from pressure vessel (35). 35 A Caution! Das Kondenswasser enthalt Ol und muss uber eine Problemstoff-Sammelstelle entsorgt werden. Every 250 operating hours • Replace air intake filter element of compressor pump. Every 500 operating hours • Ol des Verdichters ablassen und erneuern. Every 1000 operating hours • Have unit serviced by an authorized service station. This will extent the compressor's service life considerably. 5.2 Machine storage 1. Switch unit OFF and unplug. 2. Release pressure from tank and all connected air tools. 3. Store machine in such way that it cannot be started by unauthorized persons. A Caution! Do not store machine unprotected outdoors or in damp environment. Do not lay device on its side for transportation or storing. 6. Trouble Shooting A Danger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the compressor has come to a complete stop. . Ensure the compressor and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. After all servicing: . Check to see that all safety devices are operational. . Make sure that no tools or other parts remain on or in the machine. Compressor does not run: • No mains voltage. . Check cables, plug, outlet and mains fuse. • Mains voltage too low. . Use only extension cables with sufficient lead cross section (see "Technical Specifications"). Avoid using extension ca...

Эта инструкция также подходит к моделям:
Насосное оборудование - Compressor Pump Classic 50 (574.22 kb)
Насосное оборудование - Compressor Pump Classic 350 (574.22 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории