Войти:
Оценок - 4, средний балл: 4.8 ( )

Инструкция по эксплуатации Harbor Freight Tools, модель 66514

Производитель: Harbor Freight Tools
Размер: 299.45 kb
Название файла: 66514.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


To reduce the risk of electric shock, connect only to a properly grounded, grounding-type receptacle. Risk of electric shock – This pump 2. has not been investigated for use in swimming pool areas. The electrical connections must be 3. protected from moisture. If there is danger of flooding, the 4. electrical connections must be taken to higher ground. Circulation of caustic or explosive 5. fluids, as well as the circulation of abrasive materials, must be avoided at all costs. The pump must be protected from 6. frost. The pump must be protected from 7. running dry. Access by children should also be 8. prevented with appropriate measures. WARNING: Handling the Power Cord 9. on this product will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code § 25249.5, et seq.) The warnings, precautions, and in10. structions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Fluid Type The Pump is designed for use with water with a maximum temperature of 77° F (25°C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products. Specifications Flow 15.4 GPM Maximum Height 8 ft. Electrical Requirements 120 V~, 60 Hz E197437 Unpacking When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. Installation Read the entire Important Safety Instructions section at the beginning of this manual including all text under subheadings therein before set up or use of this product. To prevent serious injury from accidental operation: Unplug the Fountain Pump from its electrical outlet before assembling, inspecting, making any adjustments, or servicing. Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual. Figure 1Spray Nozzle (9) Output Tube (7) Tee Fitting System (10) Coupling Nut (5) Main Housing (4) 1. Thread the Coupling Nut (5) to the Main Housing (4). Thread the Tee Fitting System (10) to 2. the top of the Coupling Nut (5). NOTE: There are two ON/OFF Switches on the Tee Fitting System (10). Turning either Switch 90° changes it from OFF to ON, or ON to OFF. (Stamped onto the Fountain Pump parts are PLUS/MINUS symbols showing either open, or closed.) See Figure 2. Figure 2 3. Thread the Output Tube (7) to the top of the Tee Fitting System (10). Thread the Bell Nozzle (8), the Bub4. bling Nozzle (6), or the Spray Nozzle (9) to the top of the Output Tube (7) depending on what type of water display you desire. See Figure 1. The Spray Nozzle (9) is threaded to 5. the top of the Output Tube (7) when needed. Available Accessories/ Attachments This Fountain Pump comes with three separate heads for different types of water spray: Bubbling Nozzle (6) features tiny a. holes that disperse water in all directions at once. Bell Nozzle (8) will shoot water b. straight up to a maximum height of 8 ft. Spray Nozzle (9) shoots many small c. streams of water in a tight pattern. All three spray heads thread onto d. and off of the top of the Output tube (7) for quick interchanging. WARNING! Always unplug the Fountain from the power outlet and put on a pair of heavy-duty, insulated rubber gloves, before sticking hands in water to change spray heads or any other handling of the Fountain Pump. Power Supply The pump is equipped with a ground1. ed plug according to regulations. The pump is designed to be connected to 120 V~, 60 Hz receptacle. Make sure that the receptacle is suf2. ficiently secured and is in excellent condition. When the plug is inserted into the 3. receptacle the pump will be on. WARNING! If the power cord or plug is damaged, do not use the pump. The power cord or plug may only be repaired by a certified electrician. Area of use This pump is designed for use as a fountain pump in an area not used for swimming. Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. After reading these instructions, 1. consider the following points before starting the pump: Verify that the pump rests on the a. floor of the fountain. Verify that the electrical connection b. is 120 V~, 60 Hz. Verify that the electrical receptacle is c. in good condition. Verify that water and moisture cand. not get near the power supply receptacle. Verify that the pump is installed so e. as to prevent running dry. To prevent tripping, run any extension 2. cord used away from walkways that lead to your location. Place the...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории