See diagram below. PLUG REGULATED TANK PRESSURE GAUGE PRESSURE GAUGE Install the control cover. Fasten it to the manifold using the phillips screw. Install the plastic mounting ring to the regulator to fasten the top of the control cover. See photo on page 6. INSTALLATION AND BREAK-IN PROCEDURES Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air filter must be kept clear of obstructions which could reduce air delivery of the air compressor. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor head and shroud are designed to allow for proper cooling. If humidity is high a Sears air filter can be installed to remove excessive moisture. Follow the instructions packaged with the air filter for proper installation. Lubrication and Oil This unit needs no additional lubrication or oiling. Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor. If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product. • in good condition. • no longer than 50 feet. • 12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 or 16 AWG.) 7 Grounding Instructions WARNING IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK. IN THE EVENT OF A SHORT CIRCUIT, GROUNDING REDUCES THE RISK OF SHOCK BY PROVIDING AN ESCAPE WIRE FOR THE ELECTRIC CURRENT. THIS AIR COMPRESSOR MUST BE PROPERLY GROUNDED. 1. The- air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. DO NOT USE AN ADAPTER. 2. Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician. 3. Inspect the plug and cord before each use. Do not use if there are signs of damage. A DANGER RISK OF ELECTRICAL SHOCK. IF REPAIRING OR REPLACING CORD OR PLUG, THE GROUNDING WIRE MUST BE KEPT SEPARATE FROM THE CURRENT-CARRYING WIRES. NEVER CONNECT THE GROUNDING WIRE TO A FLAT BLADE PLUG TERMINAL. (THE GROUNDING WIRE HAS INSULATION WITH AN OUTER SURFACE THAT IS GREEN - WITH OR WITHOUT YELLOW STRIPES.) If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician. GROUNDING -f PIN 120 volts, 15 amps Break-In Procedures CAUTION ; Serious damage may result if the following break-in instructions are not closely followed. This procedure is only required the first time the air compressor is put into service. 1. Set the pressure switch OFF/AUTO lever to the “OFF” position. 2. Plug the power cord into the correct branch circuit receptacle. 3. Turn the regulator clockwise, opening it fully, to prevent air pressure build-up in the tank. 4. Move the OFF/AUTO lever to “AUTO". The compressor will start. 5. Run the compressor for 10 minutes. Make sure the regulator is open and there is no tank pressure buildup. 6. After 10 minutes, close the regulator by turning it counter-clockwise. The air tank will fill to cut-out pressure and then the motor will stop. OPERATING PROCEDURES 1. Before attaching air hose or accessories, make sure the OFF/AUTO lever is set to “OFF” and the air regulator is closed. (Close it by turning it counterclockwise.) 2. Attach hose and accessories. WARNING I TOO MUCH AIR PRESSURE CREATES A HAZARDOUS RISK OF BURSTING. CAREFULLY FOLLOW STEPS 3 AND 5 EACH TIME THE COMPRESSOR IS USED. COMPRESSED AIR FROM THE OUTFIT MAY CONTAIN WATER CONDENSATION. DO NOT SPRAY UNFILTERED AIR AT AN ITEM THAT COULD BE DAMAGED. SOME AIR OPERATED TOOLS OR DEVICES MAY REQUIRE FILTERED AIR. READ THE INSTRUCTIONS FOR THE AIR TOOL OR DEVICE. 3. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. 8 4. Turn the OFF/AUTO lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure. 5. Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. Your compressor is ready for use. 6. Always operate the air compressor in well-ventilated areas; free of gasoline or other solvent vapors. Do not operate the compressor near the spray area. • When you are finished: 7. Set the “OFF-AUTO” lever to “OFF”. 8. Turn the regulator counter-clockwise and set the outlet pressure to zero. 9. Remove the air tool or accessory. 10. Open the regulator and allow the air to slowly ble...
Эта инструкция также подходит к моделям:Насосное оборудование - Craftsman 919.154120 (2.23 mb)
Насосное оборудование - Craftsman 919.154320 (2.23 mb)
Насосное оборудование - Craftsman 919.154020 (2.23 mb)