Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации HP, модель 3885

Производитель: HP
Размер: 485.47 kb
Название файла: cf96e507-ffd5-4e59-9979-2c3facbdbba6.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Piping • Discharge piping should be no smaller than 2" (51 mm) diameter and kept as short as possible, avoiding unnecessary fittings to minimize friction losses. • Install an adequately sized check valve (suitable for handling 3.4" (19 mm) solids for effluent applications and 2" (50 mm) solids for sewage applications) in the discharge pipe to prevent backflow. Follow the check valve manufacturer’s installation instructions. • Install an adequately sized gate valve ABOVE the check valve for pump, plumbing and check valve maintenance. • To deter air locking, drill a 3.16" (4.8 mm) hole, 2" (50.8 mm) beyond the pump discharge connection. • All piping must be adequately supported, so as not to impart any piping strain or loads on the pump. Access Doors Access Doors • Access doors can be single or double leaf design. Doors should include a lifting handle and a lock provision for tamper resistant operation. Standard and heavy duty steel or aluminum doors are available. • The pit access door must be of sufficient size to allow for inspection, maintenance and crane or hoist service. Liquid Level Controls • Single float operation can be used on 1.3 and 1.2 HP models. Mounting of the float switch must be checked by the installer to insure proper turn on and turn off. The pump may be plugged directly into the piggy back style plug located on the cord of the float switch. • The recommended float operation sequence used with a control panel requires a three or four float system. In the three float system, the floats are designated SW-1 for the bottom float, SW-2 for the middle float and SW-3 for the top float. In a four float system the fourth float is designated SW-4. • Simplex Control – The rising liquid level raises float SW-2, turning on the pump. When the liquid level falls sufficiently, SW-1 will turn the pump off. If the influent is excessive, or if the pump fails to operate correctly, SW-3 will activate an alarm, which will remain on until manually reset. • Duplex Control – The duplex control will alternate the two pumps, causing the lead pump to change at each system cycle. When equipped with three floats, the system will cycle the same as the simplex control, described above, except that the SW-1 will cause the lead pump to alternate. • If the influent is excessive, or if the lead pump fails to operate correctly, the rising level will activate SW-3, turning on the lag pump and the alarm. As before the alarm must be manually reset. • Four Float Control – The four float system operates the same as the duplex control system, except that float SW-3 will not turn on the alarm. In this system SW-4 turns on the alarm, which again must be manually reset. • Several different float controls are available from the Goulds Catalog. NOTICE:POSITION THE FLOATS SO THAT THEY DO NOT SNAG OR TANGLE ON THE PUMP, DISCHARGE PIPING, OR OTHER EQUIPMENT. • The lower most float turns the unit off and should be set as shown in the “TYPICAL PLUMBING and INSTALLATION” drawing provided in this manual. • Increasing the distance between the SW-1 and SW-2 floats lengthens the running time. One (1) minute is the minimum recommended pump cycle time. NOTICE: DURING PUMP OPERATION, INSURE THAT THE LIQUID LEVEL DOES NOT DROP BELOW THE PUMP MOTOR FOR EXTENDED PERIODS. THIS CAN CAUSE THE PUMP MOTOR TO OVERHEAT, CAUSING MOTOR DAMAGE AND VOIDING THE WARRANTY. Pump Motor Control Panels • Control panels shall be in accordance with local and National Electrical Code requirements. • Single phase installations shall be equipped with a Goulds’ “SES” or “A” Series panel, or AS A MINIMUM, a control panel with a properly sized magnetic contactor and a disconnect switch. • Three phase installations shall be equipped with a Goulds’ “SES” or “A” Series panel, or AS A MINIMUM with a 3 pole circuit breaker, an across the line magnetic starter NEMA rated for the appropriate horsepower, ambient compensated Quick Trip Class 10 overload relays. Wiring and Grounding • Use only stranded copper wire to motor and ground. The ground wire must be at least as large as the wires to the motor. Wires should be color coded for ease of maintenance. Install, ground and wire WARNING according to local and National Electrical Code requirements. Install an all leg disconnect switch near the pump. Disconnect and lockout electrical Hazardous voltage can shock, burn or power before installing or cause death. servicing pump. Electrical supply MUST match pump’s nameplate specifications. Incor...

Эта инструкция также подходит к моделям:
Насосное оборудование - 3885 (485.47 kb)
Насосное оборудование - 3886 (485.47 kb)
Насосное оборудование - 3887 (485.47 kb)
Насосное оборудование - IM059R02 (485.47 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории