Your Defender Model draws on decades of amp design and manufacturing experience at Kustom. This model was built from the ground up to offer world-class tone, useful features and reliable performance. Inside this manual, you’ll find valuable information about the amp’s controls and specifications. Being familiar with its features will help you effectively dial in different tones. We wish you many years of enjoyment with your Kustom amplifier. V5 Front Panel 1 2 3 4 1. INPUT JACK: This .” input is for plugging in your instrument. It is intended for guitar but will accept other instruments as well. 2. VOLUME: This control determines the overall volume level of the amplifier. Due to the simplicity of the Defender V5’s all-tube circuitry, a wide range of tones can be obtained with the use of this control alone. For example, when set in its lower ranges, the sound is clean and snappy. As the Volume control is turned up, light overdrive is generated by the amp’s all-tube circuitry. This overdrive occurs naturally and is not created by any internal distortion circuit. As the Volume control is turned higher (clockwise), you’ll hear increased natural drive and compression that is great for crunchy rhythms and sustaining guitar solos. In essence, the Defender V5 generates classic overdriven tube amp tone but at lower, more manageable volume levels. (Although you may be surprised by the amount of volume that the Defender V5 can generate, so watch your ears!) 3. TONE: The Tone control adjusts the balance of low, middle and high frequencies. When set at 12 o’clock, thicker control provides an even balance of all frequencies. When turned to the left, bass notes are emphasized providing a thicker tone. Turning the knob clockwise adds high frequencies to the tone. Higher settings will provide more bite and help you cut through the mix. 4. POWER: This dual-function component is both an ON/OFF power switch and a status indicator light. When illuminated, it shows that your amplifier is ready to be played. To turn your amplifier on, press switch upward. To turn amp off, press switch downward. Note: After the power switch is turned on, the tubes must warm up for approximately one minute before you will hear sound from your amplifier. V5 Back Panel 1 32 1. AC POWER CORD RECEPTACLE: Insert the AC cord (provided) firmly into the AC connector. NOTE: Replace the AC power cord if protective jacket is damaged or ground pin is damaged or removed. The fuse is located in a housing just below the receptacle. Replace only with same type and size. To remove the fuse, remove AC power cord and pull out on the tab above the fuse symbol located on the fuse carriage. Place the new fuse in the carriage clip and re-insert. NOTE: To prevent an electrical hazard, DO NOT replace fuse without using the fuse carriage. Replace the fuse carriage if lost or damaged before re-inserting the AC power cord. 2. FUSE: The fuse is located in a fuse tray just below the receptacle. Replace only with the same type and size. For your convenience, a spare fuse is located inside the fuse tray toward the front. To replace fuse, remove AC power cord. Remove fuse tray by pulling the tab located above the fuse symbol away from the receptacle. 3: SPEAKER OUTPUTS: These 1/4” jacks are provided to connect the internal and/or external speakers to the V5. THE AMPLIFIER SHOULD NEVER BE OPERATED WITHOUT A SPEAKER PLUGGED INTO A SPEAKER JACK. ONLY ONE SPEAKER JACK CAN BE USED AT A TIME. V5 Signal Flow Diagram VOL UME TONE 16 OHMS 8 OHMS INPUT 4 OHMS 1/2 - 12AX7 Signal OUTPUTTRANSFORMER 1/2 - 12AX7 EL84 Conditioning SignalConditioning 8 OHMS 8 INCH SPEAKER INTERNAL EC Declaration of Conformity We: Kustom Musical Amplification INC. 3015 Kustom Drive Hebron, Ky 41048-0568 Tel: 1-859-817-7100 Fax: 1-859-817-7150 Declare that the product Product name: KUSTOM Product model number: DEFENDER V5 to which this declaration relates is in conformity with the following standards; EN55013: 2001/+A1: 2003+A2: 2006 Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and associated equipment. EN55020: 2007 Electromagnetic immunity of broadcast receivers and associated equipment. EN61000-3-2: 2006 Limits for harmonic current emissions (equipment input current < 16A per phase). EN61000-3-3: 2008 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated currents < 16A. EN60065: 2002+A1: 2006+A11: 2008 Safety requirements for main operated electronic and related apparatus for household and similar general use. Following the provisions of EU Council Directive(s): 72/73 EEC and 89/336/EEC. We the undersigned, hereby declare that the equipment specified above conforms to the aforementioned directive(s). Name of authorized person: James Brown, Chief Engineer Signature:______________________ Date: March 16, 2011 Kustom Musical Amplification INC. 3015 Kustom Drive Hebron, Ky 41048-0568 Tel: 1-859-817-7100 Fax: 1-859-817-715...