In correspondence to the following parameters. RPN Data-entry LSB MSB MSB parameter Data Range 00H 00H mmH Pitch Bend Sensitivity mm:00H-18H (0-+24) Default:02H MIDI Data Format MIDI Data Format e mm:00H-40H-7FH (-64-0-+63) Default : 40H 00H 02H 00H mmH Coarse Tune mm:28H-40H-58H (-24-0-+24) Default : 40H 00H 7FH 7FH — Null — 5. CHANNEL MODE MESSAGES 78H Cntrl# parameter Data Range 120 ———— 0 Terminates all sounds currently sounding. However, the status of channel messages are maintained. 79H Cntrl# parameter Data Range 121 ———— 0 The values of the following controllers will be reset to the defaults. Pitch Bend Center Channel Aftertouch 0 Modulation 0 Breath Control Max Foot Control Max Expression Max Control Change 13 Center Hold 1 Off Portamento Off Soft Pedal Off RPN Null 7BH Cntrl# parameter Data Range 123 ———— 0 Terminates all notes currently on. However, if Hold 1 is on, notes will continue sounding for the time set previously. 7CH Cntrl# parameter Data Range 124 ———— 0 Performs the same function as when an All Notes Off message is received. 7DH Cntrl# parameter Data Range 125 ———— 0 Performs the same function as when an All Notes Off message is received. It will not activate OMNI ON. 7EH Cntrl# parameter Data Range 126 Mono 0...16 Performs the same function as when an All Sounds Off message is received, and if the 3rd byte (mono number) is in the range of 0 - 16, and sets the instrument to Mono Mode. 7FH Cntrl# parameter Data Range 127 ———— 0 Performs the same function as when an All Sounds Off message is received, and sets the instrument to Poly mode. 6. CHANNEL AFTERTOUCH Status :DnH If the Part Parameter Rcv CHANNEL AFTER TOUCH = OFF, that Part will not receive Channel After Touc h Messages. 7. SYSTEM EXCLUSIVE MESSAGES If the Part Parameter Rcv SYSTEM EXCLUSIVE = OFF, that Part will not receive System Exclusive Messages. 1) MIDI Master Volume (receive only) F0H, 7FH, xnH, 04H, 01H, llH, mmH, F7H xn : n=Device Number, xn=7F : Broadcast ll : Master Volume LSB mm : Master Volume MSB When received, the Volume MSB will be effective for the System Parameter MASTER VOLUME. 2) General MIDI System On (receive only) F0H, 7EH, 7FH, 09H, 01H,F7H or F0H, 7EH, xnH, 09H, 01H, F7H xn : n=Device Number [VL70-m Native Format] F0H, 43H, 1nH, 57H, ahH, amH, alH, ddH, ~, ddH, F7H 1n : n=Device Number ah : Address High am : Address Mid al : Address Low dd : Data 1) VL System Parameters See

2) Current Voice / Common Misc Parameters See
3) VL Part Parameters See
4) Current Voice / Element Parameters See
MIDI Data Format MIDI Data Format F0H, 43H, 1nH, 4CH, ahH, amH, alH, ddH, ~, ddH, F7H 1n : n=Device Number ah : Address High am : Address Mid al : Address Low dd : Data 1) XG System On (receive only) See
2) XG System Parameters See
3) Multi Part Parameters See
When this message is sent, the preset Part Number is used. [Other] 1) MIDI Master Tune (receive only) F0H, 43H, 1nH, 27H, 30H, 00H, 00H, mmH, llH, ccH, F7H 1n : n=Device Number mm : Master Tune MSB ll : Master Tune LSB cc : Don’t care When received, the System Parameter will reflect the Master Tune. (receive only) [VL70-m Native Format] F0H, 43H, 0nH, 57H, bmH, blH, ahH, amH, alH, ddH, ~, ddH, ccH, F7H 0n : n=Device Number bm : Byte Count MSB bl : Byte Count LSB ah : Address High am : Address Mid al : Address Low dd : Data cc : Check Sum 1) VL System Parameters See
2) Cur rent Voice / Common Misc Parameters See
3) VL Part Parameters See
4) Cur rent Voice / Element Parameters See
6) Custom Voice Parameters See
7) Internal Voice Parameters See
[XG Format] F0H, 43H, 0nH, 4CH, bmH, blH, ahH, amH, alH, ddH, ~, ddH, ccH, F7H 0n : n=Device Number bm : Byte Count MSB bl : Byte Count LSB ah : Address High am : Address Mid al : Address Low dd : Data cc : Check Sum 1) XG System Parameters See
2) Multi Part Parameters See
For the Address and Byte Count, refer to the supplementary tables. Here, the Byte Count is indicated by the “TOTAL SIZE” in the table. The block’s leading byte is the Bulk Dump and Dump Request’s Address. A “Block” is the lumped together unit which is bound by the “Total Size”. The Check Sum is the value that results in a value of 0 for the lower 7 bits when the Address, Byte Count, Data, plus the Check Sum itself are added. 3) Part Assign (MIDI Parameter Change) See
F0H 43H 1nH 4CH 70H nnH ssH ppH F7H n: Device Number nn: Plug-in Board Type (PLG100-VL is "00.") ss: Serial Number (which identifies the PLG boards when two same boards are installed) 00: for first PLG100-VL 01: for second PLG100-VL pp: Part Number (to which the PLG100-VL is assigned.) 00: Part 1 . . 0F: Part 16 7F: off 8. REALTIME MESSAGES (receive only) Status :FEH Once...