Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Yamaha, модель 01V96

Производитель: Yamaha
Размер: 4.59 mb
Название файла:
Язык инструкции:ende
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


STATUS 1000nnnn 8n Note off message DATA 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(ignored) 2.2 NOTE ON (9n) Reception If [OTHER ECHO] is ON, these messages are echoed from MIDI OUT. If the [Rx CH] matches, these messages are received and used to control effects. STATUS 1001nnnn 9n Note on message DATA 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(1-127:on, 0:off) 2.3 CONTROL CHANGE (Bn) Reception If [Control Change ECHO] is ON, these messages are echoed from MIDI OUT. If [TABLE] is selected, these message are received if [Control Change Rx] is ON, and will control parameters according to the [Control assign table] settings. The parameters that can be set are defined in the Control Change Assign Parameter List. If [NRPN] is selected, these messages are received if [Control Change Rx] is ON and the [Rx CH] matches, and will control the parameter that is specified by the four messages NRPN control number (62h, 63h) and Data Entry control number (06h, 26h). Parameter settings are defined in the Control Change Assign Parameter List. Transmission If [TABLE] is selected, operating a parameter specified in the [Control assign table] will cause these messages to be transmitted if [Control Change Tx] is ON. The parameters that can be specified are defined in the Control Change Assign Parameter List. If [NRPN] is selected, operating a specified parameter will cause data to be transmitted on the [Tx CH] if [Control Change Tx] is ON, using the four messages NRPN control number (62h, 63h) and Data Entry control number (06h, 26h). Parameter settings are defined in the Control Change Assign Parameter List. This data cannot be transmitted via control change to Studio Manager since there is no guarantee that the contents of the tables will match. (Parameter Change messages will always be used.) 01V96—Bedienungsanleitung 310 Anhang C: MIDI 310 Anhang C: MIDI STATUS 1011nnnn Bn Control change DATA 0nnnnnnn nn Control number (0-95, 102-119) 0vvvvvvv vv Control Value (0-127) If [NRPN] is selected STATUS 1011nnnn Bn Control change DATA 01100010 62 NRPN LSB 0vvvvvvv vv LSB of parameter number STATUS 1011nnnn Bn Control change *1 DATA 01100011 63 NRPN MSB 0vvvvvvv vv MSB of parameter number STATUS 1011nnnn Bn Control change *1 DATA 00000110 06 MSB of data entry 0vvvvvvv vv MSB of parameter data STATUS 1011nnnn Bn Control change *1 DATA 00100110 26 LSB of data entry 0vvvvvvv vv LSB of parameter data *1) The second and subsequent STATUS need not be added during transmission. Reception must be implemented so that reception occurs whether or not STATUS is present. 2.4 PROGRAM CHANGE (Cn) Reception If [Program Change ECHO] is ON, these messages are echoed from MIDI OUT. If [Program Change RX] is ON and the [Rx CH] matches, these messages will be received. However if [OMNI] is ON, they will be received regardless of the channel. When a message is received, a Scene Memory will be recalled according to the settings of the [Program Change Table]. Transmission If [Program Change TX] is ON, this message is transmitted according to the settings of the [Program Change Table] on the [Tx CH] channel when a scene memory is recalled. If the recalled scene has been assigned to more than one program number, the lowest-numbered program number will be transmitted. Transmission to Studio Manager using Program Change messages will not be performed since there is no guarantee that the contents of the tables will match. (Parameter Changes will always be used.) STATUS 1100nnnn Cn Program change DATA 0nnnnnnn nn Program number (0-127) 2.5 TIMING CLOCK (F8) Reception It is used to control effects. This message is transmitted 24 times per quarter note. STATUS 11111000 F8 Timing clock 2.6 ACTIVE SENSING (FE) Reception Once this message has been received, the failure to receive any message for an interval of 400 ms or longer will cause MIDI transmission to be initialized, such as by clearing the Running Status. STATUS 11111110 FE Active sensing 2.7 SYSTEM RESET (FF) Reception When this message is received, MIDI communications will be cleared, e.g., by clearing the Running Status. STATUS 11111111 FF System reset 2.8 SYSTEM EXCLUSIVE MESSAGE (F0) 2.8.1 MIDI MACHINE CONTROL (MMC) These messages are transmitted when the Machine Control section of the 01V96 is operated. For details, refer to the MMC specification. 2.8.2 BULK DUMP This message sends or receives the contents of various memories stored within the 01V96. The basic format is as follows. For DUMP DATA F0 43 0n 7E cc cc tt mm mm [Data …] cs F7 For DUMP REQUEST F0 43 2n 7E tt mm mm F7 n Device Number cc cc DATA COUNT (the number of bytes that follow this, ending before the checksum) 4C 4D 20 20 38 43 39 33 Model ID tt DATA TYPE mm mm DATA NUMBER cs CHECK SUM A unique header (Model ID) is used to determine whether the device is a 01V96. CHECK SUM is obtained by adding the bytes that follow BYTE COUNT (LOW) and end before CHECK SUM, taking the binary compliment of this sum, and then se...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории