Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Roland, модель SC-55MKII

Производитель: Roland
Размер: 5.55 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Then no new voice should be assigned. Example I. On MIDI Description Result 90 3C 40 Note on C4 BO 54 3C Portamento Control from C4 90 40 40 Note on E4 80 3C 40 Note off C4 80 40 40 Note off E4 C4 on no change Re - tuning (glide) from C4 to E4 no change E4 off Example 2. On MIDI Description DO 54 3C Portamento Control from C4 90 40 40 Note on E4 80 40 40 Note off E4 O Effect! depth (Reverb send level) no change E4 on with glide from C4 E4 off Status BnH Second 5BH = MIDI channel number = Reverb send level Third vvH : OH - FH (ch.l - ch.16) : 00H - 7FH (0 - 127) *Effectl depth messages control the Send Level of the specified channel (part) to the internal Reverb unit. О Effect3 depth (Chorus send level) itus Second H 5DH = MIDI channel number = Chorus send level : OH - FH (ch.l : 00H - 7FH (0 ch.16) 127) ♦ Effects depth messages control the Send Level of the specified channel (part) to the internal Chorus unit. Status BnH BnH Second 63H 62 H n - MIDI channel number mm = MSB of Ihe NRPN II - LSB of the NRPN : Oil - FH (ch.l - ch.16) ♦ Recognized when “Rx.NRPN = ON". “Rx.NRPN" is set to OFF by receiving “Turn General MIDI System On", and it is set to ON by “GS RESET”. ♦ The values set by NRPN won’t reset by receiving new Program Change messages or Reset All Controllers. ♦ ♦ NRPN ♦ ♦ An NRPN (Non Registered Parameter Number) is an expanded control change message. Each function of an NRPN is described by the individual manufacturer. To use NRPN, set NRPN number (MSB/LSB) before sending data. Then send data by Data entry message (Control Change S 6/38). And then, it is recommended to send RPN null (RPN number = 7FH/7FH) to prevent the data from being unexpectedly change. For more explanation, refer to Chapter 4.Useful Information, Example of actual MIDI messages < EXAMPLE 4 >. You can change the following parameters using an NRPN. Description NRPN MSB LSB Data entry MSB 0111 081! mmH 01H 0911 mmll 01И 0АН mmH 01H 20H mmH 0П1 2111 mmll 0111 63H mmH 01H 64H mmH 01H 66H mmH Vibrato rate relative change on specified channel mm: 0EH - 401! - 721! (- 50 - 0 - + 50) Vibrato depth relative change on specified channel mm: 0EH - 40H - 72H (-50 - 0 - +50) Vibrato delay relative change on specified channel mm: OEM - 40H - 72H (-50 - 0 - -50) TVF cutoff frequency relative change on specified channel mm: 0EH - 401! - 72H (- 50 - 0 - + 50) TVF resonance relative change on specified channel mm: 0EH - 40H - 72H (- 50 - 0 - +50) TVF&TVA Env. Attack time relative change on specified channel mm : 0EH - 40H - 72H ( - 50 - 0 - + 50) TVF&TVA Env. Decay time relative change on specified channel mm : 0EH - 40H - 72H ( - 50 - 0 - +50) TVF&TVA Env. Release time relative change on specified channel mm: 0EH - 40H - 72H (- 50 - 0 - - 50) Pilch coarse of drum instrument relative change on specified drum instrument rr :key number of drum instrument mm:00H - 40H - 7FH (-64 - 0 - +63 semiione) TVA level of drum instrument absolute change on specified drum instrument rr : key number of drum instrument mm:00H - 7FH (zero - maximum) Panpot of drum instrument absolute change on specified drum instrument rr :key number of drum instrument mm:00H, 01H - 40H - 7FH {Random, Left - Center - Right) Reverb send level of drum instrument absolute change on specified drum instrument rr :key number of drum instrument mm:00H - 7FH (zero - maximum) Chorus send level of drum instrument absolute change on specified drum instrument rr : key number of drum instrument mm:00H - 7FH (zero - maximum) ♦ Data entry LSB is ignored. ♦The relative change means that the parameter value (e.g.-50 - 0 - +50) will be added to the preset value. ♦The absolute change means that the parameter value will Ix? replaced by the received value. 91 Orpn msb/lsb • Pitch bend change Status Bnif BnH Second 65 H 64H n = MIDI channel number mm - MSB of the RPN II = MSB of the RPN : OH - FH (ch.l - ch.16) ♦ Ignored when “Rx.RPN = OFF". ♦ The values set by an RPN won't be reset by receiving new Program Change messages or Reset AH Controllers. ♦ ♦ RPN ♦ ♦ An RPN (Registered Parameter Number) is an expanded control change message. Each function of an RPN is described by the MIDI Standard. To use an RPN, set the RPN number (MSB/LSB) before sending data. Then send data by Data entry message (Control Change # 6/38). It is then recommended to send RPN null (RPN number = 7FH/7FH) to prevent the data from being unexpectedly change. For more explanation, refer to Chapter 4.Usefu! Information, Example of actual MIDI messages < EXAMPLE 4 >. You can change the following parameters using an RPN. RPN MSB LSB Data entry MSB LSB Description Pitch bend sensitivity mm ; ООН - 18H (0 24 semitone) Default value = 02H (two semitones) H : ignored (value - ООН) (Up to 2 octaves) Master fine tuning mm.ll: 00 ООН - 40 ООН - 7F 7FH (-8192 x 100/8192 - О -т 8191 х 100/8192 cents) Master coarse tuning mm: 28H - 40H - 58H (...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории