Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Roland, модель RD-700SX

Производитель: Roland
Размер: 5.13 mb
Название файла:
Язык инструкции:enfr
Фото и характеристики  Roland  RD-700SX
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


The Edit Menu screen appears. 2 Press CURSOR [ ] to select “9.Utility.” 3 Press [ENTER] to display the Utility screen. 4 Press CURSOR [ ] to select “Factory Reset All.” Restoring the Factory Settings (Factory Reset) Executing this operation deletes the Setup settings ( Getting Ready 1 Press [EDIT], getting the indicator to light. The Edit Menu screen appears. 2 Press CURSOR [ ] to select “9.Utility.” 3 Press [ENTER] to display the Utility screen. 4 Press CURSOR [ ] to select “Factory Reset All.” Restoring the Factory Settings (Factory Reset) Executing this operation deletes the Setup settings (p. 56). If you want to keep any internally stored content, use the “Bulk Dump (Bulk Dump SETUP)” procedure to save the data to an external sequencer (p. 99). Notes Never turn off the power during Factory Reset (while “Now, Executing” appears in the display). Turning off the power while Factory Reset is in progress may result in corrupted internal data and may prevent the power from being turned on again. If you have confirmed that the internal data has been lost, or if a similar problem exists, consult the retailer from whom you purchased the instrument, or the nearest Roland Service Center. Note, however, that Roland assumes no liability, including compensation, for consequences arising from any loss of data. 12,43,5,6,7 When making USB connections, be absolutely sure to disconnect the USB cable before starting. Instead of selecting with the CURSOR, you can press TONE SELECT [9] to display the Utility Edit screen directly. Getting Ready 6 Press [ENTER]. The confirmation message appears. To cancel the Factory Reset, press [EXIT]. 7 Press [ENTER] once again to start the Factory Reset operation. During the execution, “Executing... Don’t Power OFF” appears in the display. After the Factory Reset operation is finished, the ONE TOUCH screen will appear. 8 Turn off the power to the RD-700SX, then turn it on again. You can also restore only part of the setting to their factory status. Refer to “Restoring the settings to the factory condition (Factory Reset)” (p. 100). Getting Ready 6 Press [ENTER]. The confirmation message appears. To cancel the Factory Reset, press [EXIT]. 7 Press [ENTER] once again to start the Factory Reset operation. During the execution, “Executing... Don’t Power OFF” appears in the display. After the Factory Reset operation is finished, the ONE TOUCH screen will appear. 8 Turn off the power to the RD-700SX, then turn it on again. You can also restore only part of the setting to their factory status. Refer to “Restoring the settings to the factory condition (Factory Reset)” (p. 100). Adjusting the Display Contrast (LCD Contrast) The characters in the display may be difficult to view immediately after turning on the power or after extended use; this may also be because of where and how the display is situated. In such instances, adjust the display contrast by turning the CONTRAST knob on the front panel. Getting Ready 1 Press [EDIT], getting the indicator to light. The Edit Menu screen appears. 2 Press CURSOR [ ] to select “0.System.” 3 Press [ENTER] to display the Edit screen. 4 Press CURSOR [ ] to move the cursor to the “Master Tune” parameter. 5 Press [INC]/[DEC] to select the value (415.3–440.0–466.2). 6 Press [EDIT] to make the indicator go dark. You are returned to the Tone screen. Tuning to Other Instruments’ Pitches (Master Tune) 1,62,43 5 You can directly display the System Edit screen by pressing TONE SELECT [0] instead of selecting with CURSOR. For faster value increases, keep [INC] pressed down and press [DEC]. For decreasing value faster, keep [DEC] pressed down and press [INC]. If you want to save this setting, press [F1(WRITE)]. Settings saved in the RD-700SX are not deleted even when the power is turned off. Getting Ready 1 Press [EDIT], getting the indicator to light. The Edit Menu screen appears. 2 Press CURSOR [ ] to select “0.System.” 3 Press [ENTER] to display the Edit screen. 4 Press CURSOR [ ] to move the cursor to the “Master Tune” parameter. 5 Press [INC]/[DEC] to select the value (415.3–440.0–466.2). 6 Press [EDIT] to make the indicator go dark. You are returned to the Tone screen. Tuning to Other Instruments’ Pitches (Master Tune) 1,62,43 5 You can directly display the System Edit screen by pressing TONE SELECT [0] instead of selecting with CURSOR. For faster value increases, keep [INC] pressed down and press [DEC]. For decreasing value faster, keep [DEC] pressed down and press [INC]. If you want to save this setting, press [F1(WRITE)]. Settings saved in the RD-700SX are not deleted even when the power is turned off. X Basic Organization of the RD-700SX The RD-700SX can be divided into two sections: a keyboard controller section and a sound generator section. The two sections are connected internally by means of MIDI. Keyboard Controller Section (controllers such as keyboard, pitch bend lever, etc.) Sound Generator Section Play Keyboard Controller Section This section includes ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории