Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Roland, модель DIF-800

Производитель: Roland
Размер: 1.88 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If your DM-800 has a version of system software earlier than 2.00, you must have the software upgraded. * For software upgrades, contact a nearby Roland service center. Connecting a DM-800 and an ADAT * Audio tracks 1-8 of the ADAT correspond to digital input/output 1-8 of the DM-800's RMDB connector. As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. ADAT 'nnnmnrfnl ir - SYNC OUT DIGITAL 1 \ DIGITAL OUTPUT/ 1 INPUT DIF-800 SYNC IN/OUT I rPl g ffi Bp. § ADAT ADAT OPTICAL OPTICAL IN OUT DM-800 ADAT 1 a ; ■ ■ ■ m OFF OFF DIF-800 Ç3 E3 «€*522^’ •£§* B i ADAT ADAT OPTICAL OPTICAL IN OUT DM-800 n \RMDB r r -, \hmdb p DM-BOO MW -na o e s o e O m sa ■ ^41 __; o! icn ■“ — ’o' -~.i ; ■ ioio^ojo!©:©;©©. 'o; , ... . ; 0 « © o1« o' rr ~ ^ jf 1; ^4.; :0: ; ¡o;o 010:0:010(9' ¡c ,—, IMIIIii '. .. lUlimill ' Connecting a DM-800 and a DA-88 Note: • When controlling the DM-800 from the DA-88, a Tascam RC-848 remote control unit is required. (If there is no RC-848, the DM-800 cannot be controlled.) • DM-800 synchs to the ABS time(Absolute Time) on the DA-88. • Audio tracks 1-8 of the DA-88 correspond to digital input/output 1-8 of the DM-800's RMDB connector. l.As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. DA-88 SYNC OUT J DIGITAL I/O REMOTE IN/SYNC IN (TO DA-88)/ tof-i M;*n ■ -■ iw ;l; sUels OFF OFF DIF-800 2. Set the DIF-800's device ID knob to a position other than 0 (zero). 3.Set the DA-88's MACHINE ID to 0 (zero). NOTE: Make sure that the DIF-800's device ID and the DA-88's machine ID are not the same. If the IDs are the same, the system may malfunction. l.As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. DA-88 OWKX,___ ooooe e -< tn i* =sz iO 1-1 leloe.eis eo'e; •« —, ■ Mill II ¡1 2. Set the DIF-800's device ID knob to 0 (zero). 3,On the DA-88 that is connected directly to the DIF-800, set the MACHINE ID to 0 (zero). 9 Connecting a DM-800 and a VCR Note: • In order for the DM-800 and the video device to synchronize correctly, the same reference video signal must be provided to the video device and to the DIF-800. ♦ As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. VCR - ♦ As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. VCR n \HMDB r bwkw».——i— 1 1 / \RMDB _ ftooae e:r-> c.- • \— e ss-r. . ..... a, = 1 © et a • s.es ,e. REFERENCE VIDEO SIGNAL ¡eooeje io. i_ :l;i !© _ " e se e e e« e o illllllllll REFERENCE VIDEO SIGNAL 10 To turn the power on................................ Before you turn on the power of each device, make sure that all devices are connected correctly. Note: To prevent damage to your monitor speakers etc., lower the volume of your audio equipment before turning on any equipment. l.If you are using a video device, turn on the power of the reference video signal source first. 2.Tum on the DIF-800 power. The status indicator will blink green. * When power is turned on, the DIF-800's protection circuit requires a few moments while it readies the unit for normal operation. 3.Tum on the DM-800 power and the power of any SCSI devices connected to the DM-800. The status indicator of the DIF-800 will change to steadily lit green. 4.Tum on the power of your ADAT or DA-88, video device, and audio equipment. 5. While the DM-800 checks the DIF-800 connections, it will display a message like the following. Loading Startup Project-Found DIF-800 Ver.1.00 * Do not connect or disconnect cables while the unit is operating. To turn the power off................................ 1.Turn off the power of the ADAT, DA-88, video device, and audio devices. 2. Perform shut-down operations for the DM-800 and the SCSI devices connected to the DM-800, and turn their power off. 3.Tum off the DIF-800 power. 4. If you are using a video device, him off the source of the reference video signal. 800 Parameter Settings Various parameter settings need to be made on the | 4. Set the Time Base as appropriate for your situation. DM-800 so that control commands can be transmitted and received, and for synchronization to take place. 1.Press [SYSTEM]. The DM-800 will enter System mode. 2. Press [F4] (Page-) or [F5] (Page+) several times to access the Project Parameter 1 screen. Project- P3T3r't0t-0r 1 Sampling Clock source-. Tine Base ............. SMPTE Rate/ForMat ..... Error Level ..... RMDB ■iMaareii 30 - Non 5 Offset Bjjjjggtfige 3.Set the Sampling Clock Source as appropriate for your situation. When using the DIF-800, set this to RMDB. Internal: The sampling clock will be generated from the DM-800 internal clock. Digital IN: The sampling clock will be taken from the digital device connected to the digital input connector. Use this setting when digitally ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории