Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Roland, модель VK-88

Производитель: Roland
Размер: 3.12 mb
Название файла:
Язык инструкции:ende
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


(p. 77) (factory setting: Channel 1). * Not received by the Orchestral Tones part. * Not received when MIDI GENERAL CONTROLLERS SWITCH (p. 76) is OFF. .Hold 1 (Controller number 64) Status 2nd byte 3rd byte BnH 40H vvH n = MIDI channel number: 0H - FH (ch.1 - ch.16) vv = control value: 00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON * When inputting via the MIDI PEDAL IN connector, this functions the same as an hold pedal connected to the VK-88’s HOLD PEDAL jack. .Sound Controller 1-9 (Controller number 70-78) (Harmonic Bars) Status 2nd byte 3rd byte BnH ccH vvH n = MIDI channel number: 0H - FH (ch.1 - ch.16) cc = control change number: 46H - 4EH (70-78) vv = control value: 00H - 7FH (0 - 127) * Receives harmonic bar values. * Not received by the Orchestral Tones part. * Messages input through the MIDI IN connector can be used to control specific Parts, according to the MIDI channel numbers of the MIDI messages. Messages input via the MIDI PEDAL IN connector are received as messages for the Pedal Part, regardless of the channel number. * Not received when MIDI SOUND CONTROLLERS SWITCH (p. 76) is OFF. cc | H.Bar Feet -------------+------------------------------------46H (70) | 16’ 47H (71) | 5 1/3’ 48H (72) | 8’ 49H (73) | 4’ 4AH (74) | 2 1/3’ 4BH (75) | 2’ 4CH (76) | 1 3/5’ 4DH (77) | 1 1/3’ 4EH (78) | 1’ * Control values and harmonic bars are related as follows. vv | H.Bar Level -------------+--------------------------------00H - 0EH | 0 0FH - 1CH | 1 1DH - 2AH | 2 2BH - 38H | 3 39H - 47H | 4 48H - 55H | 5 56H - 63H | 6 64H - 71H | 7 72H - 7FH | 8 .General Purpose Controller 5 (Controller number 80) (Rotary Speed) Status 2nd byte 3rd byte BnH 50H vvH n = MIDI channel number: 0H - FH (ch.1 - ch.16) vv = control value: 00H - 7FH (0 - 127) * When signals are received through the MIDI IN connector, reception is over the channel specified in CONTROL MIDI CH. (p. 77) (factory setting: Channel 1). * Not received by the Orchestral Tones part. * Not received when MIDI GENERAL CONTROLLERS SWITCH (p. 76) is OFF. MIDI Implementation .General Purpose Controller 6 (Controller number 81) (Rotary Brake) Status 2nd byte 3rd byte BnH 51H vvH n = MIDI channel number: 0H - FH (ch.1 - ch.16) vv = control value: 00H - 7FH (0 - 127) 0-63 = SPIN, 64-127 = BRAKE * When signals are received through the MIDI IN connector, reception is over the channel specified in CONTROL MIDI CH. (p. 77) (factory setting: Channel 1). * Not received by the Orchestral Tones part. * Not received when MIDI GENERAL CONTROLLERS SWITCH (p. 76) is OFF. .RPN MSB/LSB (Controller number 100, 101) Status 2nd byte 3rd byte BnH 65H mmH BnH 64H llH n = MIDI channel number: 0H - FH (ch.1 - 16) mm = upper byte (MSB) of parameter number specified by RPN ll = lower byte (LSB) of parameter number specified by RPN <<< RPN >>> Control Changes include RPN (Registered Parameter Numbers), which are extended. When using RPNs, first RPN (Controller numbers 100 and 101; they can be sent in any order) should be sent in order to select the parameter, then Data Entry (Controller numbers 6 and 38) should be sent to set the value. Once RPN messages are received, Data Entry messages that is received at the same MIDI channel after that are recognized as changing toward the value of the RPN messages. In order not to make any mistakes, transmitting RPN Null is recommended after setting parameters you need. This device receives the following RPNs. RPN Data entry MSB, LSB MSB, LSB Notes 00H, 00H mmH, llH Pitch Bend Sensitivity mm: 00H - 18H (0 - 24 semitones) ll: ignored (processed as 00H) Up to 2 octave can be specified in semitone steps. * Not received by the Organ part. 00H, 01H mmH, llH Master Fine Tuning mm, ll: 20 00H - 40 00H - 60 00H (-8192 x 50 / 8192 - 0 - +8192 x 50 / 8192 cent) * Not received by the Organ part. 00H, 02H mmH, llH Master Coarse Tuning mm: 10H - 40H - 70H (-48 - 0 - +48 semitones) ll: ignored (processed as 00H) * Not received by the Organ part. 7FH, 7FH ---, ---RPN null RPN and NRPN will be set as “unspecified.” Once this setting has been made, subsequent Parameter values that were previously set will not change. mm, ll: ignored Program Change Status 2nd byte CnH ppH n = MIDI channel number: 0H - FH (ch.1 - ch.16) pp = program number: 00H - 3FH (prog.1 - prog.64) (registration) 00H - 07H (prog.1 - prog.8) (Orchestral Tones) * Not received when MIDI PROGRAM CHANGE SWITCH is OFF (factory setting: ON). * Registrations are received on the channel specified by CONTROL MIDI CH. (p. 77) (factory setting: channel 1). The Orchestral Tones part is received on the channel specified by ORCHESTRAL TONES MIDI CH. (factory setting: Upper Orchestral Tones =channel 4, Lower Orchestral Tones = channel 5, Pedal Orchestral Tones = channel 6). Channel Pressure Status 2nd byte DnH vvH n = MIDI channel number: 0H - FH (ch.1 - ch.16) vv = Channel Pressure: 00H - 7FH (0–127) * Received only for the Orchestral Tones Part. Pitch Bend Change Status 2nd byte 3rd byte EnH llH mmH n = MIDI chann...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории