Войти:
Оценок - 5, средний балл: 3.6 ( )

Инструкция по эксплуатации Roland, модель VE-20

Производитель: Roland
Размер: 39.52 mb
Название файла:
Язык инструкции:itenesfrdenlpt
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


*2 Available if Type is set to DISTORTION. *3 Available if Type is set to STROBE or FLANGER. *4 Available if Type is set to CHORUS. DOUBLE/HARMONY *1 Available if Type is set to Double. *2 Available if Type is set to -1 to +1 oct or Unison. DELAY REVERB Parameter guide Sound parameters Parameter Explanation On, Off Switches DYNAMICS on/off. Depth Adjusts the depth of DYNAMICS. Enhance Adjusts the depth of the Enhance effect. Higher settings will give the sound sharper definition. Parameter Explanation On, Off Switches PITCH CORRECT on/off. Type Soft The pitch will be corrected smoothly. Hard The pitch will be corrected quickly. Electric Corrects pitch variation to a stair-step change. Robot Corrects the pitch to the specified note. Scale *1 Chromatic The pitch is corrected to the nearest chromatic semitone. Maj (Min) The pitch is corrected according to the Key setting. Gender Changes your voice to a masculine or feminine character. Octave *1 Specifies the amount by which the pitch will change. Key *2 Specifies the key of the song you’re singing (p. 11). Note *3 Fixes the pitch. Parameter Explanation On, Off Switches TONE/SFX on/off. Type PREAMP Adjusts the tonal character. DISTORTION Produces a distorted voice. RADIO Produces a radio voice. STROBE Finely slices the voice. CHORUS Adds richness to the voice. FLANGER Adds a “swooshing” modulation. Gain *1 Adjusts the level. Bass *1 Adjusts the tone quality of the low-frequency range. Middle *1 Adjusts the tone quality of the mid-frequency range. Middle f *1 Adjusts the frequency affected by the Middle parameter. Treble *1 Adjusts the tone quality of the high-frequency range. Drive *2 Adjusts the degree of distortion. Tone *2 Adjusts the tonal character. Speed *3 Specifies the speed. Depth *4 Adjusts the depth of CHORUS. Parameter Explanation On, Off Switches DOUBLE/HARMONY on/off. Part1 (2) Type Off Turns the part off. Double Produces a double-tracking effect. -1–+1 oct If you’ve specified the key of your song (p. 11), harmony that is suitable for that key will be added at the interval you specify here. Unison By changing the vocal character, this produces the impression that another person is singing the same melody along with you. Part1 (2) Dbl *1 Adjusts the intensity of the Double effect in three levels (Light / Normal / Deep). Part1 (2) Lev *2 Adjusts the volume of the part. Part1 (2) Gender *2 Transforms the voice by giving it a masculine or feminine character. Part1 (2) Pan L50–Center– R50 Specifies the panning (stereo position) of the sound. Key *2 Specifies the key of the song you’re singing (p. 11). Parameter Explanation On, Off Switches DELAY on/off. Time Adjusts the delay time (1–4000 ms). Feedback Adjusts the amount of delayed sound that is repeated. DelayLevel Adjusts the volume of the delayed sound. Parameter Explanation On, Off Switches REVERB on/off. Type Ambience Produces a sense of spatial depth. Room Produces warm reverberation. Hall 1 Produces clear and spacious reverberation. Hall 2 Produces mild and understated reverberation. Plate Produces metallic-sounding reverberation with an extended high range. Size Adjusts the size of the room (space) to vary the reverb time. RevLevel Adjusts the volume of the reverberation. Parameter Explanation 19 Appendix Es pano l Po rt ug ue s Ne der la n ds Italian o Fr an c a i s De ut sc h Eng l i s h CONTROL PEDAL MASTER These parameters are applied to the entire VE-20. SETUP FACTORY RESET Power doesn’t come on .. Have the batteries run down? > Replace them with new batteries (p. 3). * The batteries included with the VE-20 are meant only to confirm that the unit is functional at the factory. .. Is the specified AC adaptor (PSA series; optional) connected correctly? > Check the connections again (p. 7). Never use any AC adaptor other than the adaptor specified. .. Could the POWER switch be OFF? > Turn the POWER switch ON (p. 4). No sound/volume is low .. Is the other equipment connected correctly? > Check the connections again (p. 7). .. Could the volume or input gain of the connected mixer or recorder be lowered? > Check the settings of the connected device. .. Could the Phantom Power parameter be set to Off? > If you’re using a condenser mic that requires phantom power, set the Phantom Power parameter to the On (p. 16). .. Could the MicSens or Volume settings be too low? > Adjust these to appropriate values (p. 4). .. Have the batteries run down? > Replace them with new batteries (p. 3). * The batteries included with the VE-20 are meant only to confirm that the unit is functional at the factory. The POWER indicator has gone dim .. Is the specified adaptor (PSA series; optional) properly connected? > Check the connection once more (p. 7). * Never use any AC adaptor other than one specified for use with the VE-20. .. Have the batteries run down? > Replace them with new batteries (p. 3). * When the indicator goes dim or no longer lights while the effect is on, it means that the batteries must be replaced. *...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории