Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Roland, модель SC-7

Производитель: Roland
Размер: 11 mb
Название файла:
Язык инструкции:ende
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


63); Hold OFF 40H...7FH(64...127) ; Hold ON (7) Effectl depth (Reverb depth) Status Second Third BnH 5BH wH n = MIDI channel w = Reverb send level : 0H....FH (chi ...chi6) : 00H...7FH (0...127) Real sending level is determined by Volume value, Expression value, Master Volume value and this value. ( Refer to BLOCK DIAGRAM on page P.36) (8) Effect3 depth (Chorus depth) Status BnH Second 5DH Third wH n = MIDI channel w = Chorus send level :0H....FH (chi...chi6) : 00H...7FH (0...127) * Real sending level is determined by Volume value, Expression value, Master Volume value and this value. ( Refer to BLOCK DIAGRAM on page P.36) ( 9) NRPN MSB/LSB Status Second Third BnH 62H IIH BnH 63 H mmH n = MIDI channel : 0H....FH (chi ...chi 6) II = LSB value of the parameter specified by NRPN mm = MSB value of the parameter specified by NRPN * At power up or receiving a 'Turn General MIDI System On (FO 7E 7F 09 01 F7)" message, NRPN is not recognized ( Rx.NRPN = OFF). System Exclusive message can enable NRPN. ( Refer to P.35 'PATCH PARAMETER' ) //NRPN// NRPN (Non Registered Parameter Number) is the expanded Control Change message to control native functions of each MIDI instrument. NRPN is used to modify tone parameters that are relative values from preset or absolute values. NRPN MSB/LSB should be set before sending data entry. NRPN is available for only the drum Part in the SC-7. NRPN Data Entry MSB LSB MSB LSB Description 18H rrH mmH — Pitch coarse of Drum Instruments (relative change) mm : 00H...7FH (-64...0...+63 semitones) 1 AH rrH mmH — TVA level of Drum Instruments (absolute change) mm : OOH...7FH 1CH rrH mmH — Panpot of Drum Instrument (absolute change) mm : 01 H...40H...7FH (Left-Center-Right) 1DH rrH mmH — Reverb send depth of Drum Instruments (absolute change) mm : 00H...7FH 1 EH rrH mmH — Chorus send depth of Drum Instruments (absolute change) mm : OOH...7FH rr : key number of Drum and Percussion * LSB of data entry is ignored. * Relative parameter specifies relative value regarding preset value as 40H * Absolute parameter specifies absolute value regardless of current value. « How to use NRPN » Recognizing NRPN is always off at power up or when receiving 'Turn CM System On', because parameters specified by NRPN can be assigned native functions of each MIDI instrument and may cause problems. NRPN is available for only the drum Part in the SC-7. (1) Enable to receive NRPN by System Exclusive message 'FO 41 10 56 12 01 00 01 01 sum(7D) F7' Parti 0 = Drum part (21 Specify the parameter to NRPN B9 63 mm (B9) 62 II mm: parameter II: key number of Drum instrument (3i Set parameter value using data entry (B9) 06 w vv: parameter value ( used only MSB in SC-7 ) (4) Reset NRPN ( no parameter specified by NRPN ) (B9) 65 7F (B9) 64 7F Once the parameter is specified by NRPN, all values sent by data entry are valid. II is recommended to reset NRPN after sending the value so as to avoid any problems. (10) RPN MSB/LSB Status Second Third BnH 64H IIH 8nH 65H mmH n = MIDI channel : 0H....FH (chl...ch16) II = LSB of parameter specified by RPN mm = MSB of parameter specified by RPN There is no change in parameter values via RPN by Program Change messages. //RPN// RPN (Registered Parameter Number) is the expanded Control Change message defined by the MIDI standard. Each RPN function is described in "MIDI 1.0 DETAILED SPECIFICATION DOCUMENT'. RPN MSB/LSB should be set before sending data entry. RPN Data Entry MSB LSB MSB LSB Description 00H 00H mmH — Pitch bend sensitivity mm : 00H...18H (0...24 semitones) * Up to 2 octaves; default setting is 2 semitones OOHOIH mmH IIH Master fine tuning mm,II : 00H,0OH...4OH,00H...7FH,7FH (-100......0......-»-100 cent) 00H 02H mmH— Master coarse tuning mm : 28H...40H...58H (-24....0....+24 semitones) 7FH 7FH--RPN reset * No specified parameter is assigned to RPN and NRPN. Current value is not affected. « How to use RPN » (1) Specify the parameter to RPN B9 65 mm (B9) 64 II mm: MSB of parameter name II: LSB of parameter name (2) Set parameter value using data entry (B9) 06 vm (B9I 26 vl vm : MSB of parameter value vl: LSB of parameter value Sending only the MSB value is possible, if the required resolution of the value is 128 steps. Omitting the MSB value is allowed, if the required range of the value is less than 128. (3) Reset RPN ( no parameter specified by RPN ) (B9) 65 7F (B9) 64 7F Once the parameter is specified by RPN, all values sent by data entry are valid. It is recommended to reset RPN after sending the value so as to avoid any problems. <4> PROGRAM CHANGE Status Second CnH ppH n = MIDI channel pp = Program number : 0H....FH (chi...chi6) ; 00H...7FH (0...127) • Current active voices are not affected when receiving PROGRAM CHANGE messages. New sounds will be played after receiving PROGRAM CHANGE messages. <5> CHANNEL PRESSURE Status Second DnH wH n = MIDI channel w = Value : 0H....FH (chi ...ch16) :...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории