Allow 1/4” minimum clearance at the back wall above the countertop. Wall coverings, counters and cabinets around range must withstand heat (up to 200°F) generated by the range. 4 NOTE: Drop-In Ranges are designed to hang from the countertop only. Do not install on a platform or support rails. Installation Instructions Installation Instructions PREPARE TO INSTALL THE RANGE The Standard Installation of this Drop-In Range is to hang by the countertop on the side metal flanges under cooktop. This Range must not be installed on a base or sub structure (2”x 4” support). If the construction of your cabinet cannot provide a 1/4” flat area at the back of the countertop opening, consider changing the countertop to accommodate this dimension. Center the 30” wide opening over the adjacent cabinets and mark with a straight edge. Using a straight edge, mark the back line at 23-3/16” from the front edge of the counter. Be careful not to damage the adjacent cabinets while cutting the countertop. Remove countertop raised edge, if incorporated. (See illustration on page 4.) 4 3 2 1 STANDARD INSTALLATION Wall 1/4” min. flat 23-3/16” 9/16” min. flat 9/16” min. flat 29-15/16”– 30-1/16” smooth cut 25” typically 1/4” R Flat area Countertop Range support Braces secured between the underside of the countertop and the cabinet if required to obtain 1-1/4” minimum thickness (two sides) 5 Installation Instructions ELECTRICAL CONNECTIONS 3 2 1 4 Remove house fuse or open circuit breaker. Loosen screws for the junction box cover and rotate out of place or remove the cover. Examine the junction box location to determine the best routing of the conduit, and select the best available 7/8” diameter knockout. Avoid using holes in the top of the junction box to prevent the conduit from interfering with the back of the range. Break open the selected knockout by placing a bladed screwdriver on the scored opening in the junction box and striking the screwdriver with a hammer. (Pliers may be required to complete the removal of the knockout.) Position the range in front of the opening, but slightly to the side, in a manner so 5 7/8” knockout Cover rotated from box opening WARNING: Improper connection of aluminum house wiring to copper leads can result in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow the manufacturer’s recommended procedure closely. GENERAL NOTE FOR ALL WIRE NUT APPLICATIONS: THE PROPER SIZE WIRE NUT SHALL BE PLACED OVER THE STRIPPED LEADS AND THE WIRE NUT TWISTED UNTIL THE WIRE NUT CAN NOT BE PULLED FROM THE LEADS. NO CONDUCTOR SHALL BE EXPOSED IN THE CONNECTION. THE EXCEPTION TO THE CONDUCTOR BEING EXPOSED IS THE BARE COPPER GROUND CONNECTION. BREAKER OR FUSE SIZE 240V 40 Amps + 208V 40 Amps + + NOTE: Check Local Codes for required breaker size. 6 that a person can enter the opening to wire the range to the house wiring in the junction box. Feed wires and conduit through the open hole and snap the conduit fitting into the hole. Route the conduit in a manner that will not interfere with the rear wire cover. The conduit must be routed below the wire cover. 6 Installation Instructions THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION When connecting to a 3-conductor branch circuit, if local codes permit: Connect the bare oven ground conductor with the crimped neutral (white) lead to the branch circuit neutral (white or gray in color), using wire nuts. Connect the oven red lead to the branch circuit red lead, and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see “WARNING” note (see page 6). 7b 7a Branch circuit Black Alternate knockout Neutral bare wire connection Range conduit snaps into box Red Ground and neutral wires (white) NEW CONSTRUCTION AND FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION • When installing in new construction, or • When installing oven in a mobile home or recreational vehicle, or • When local codes do not permit grounding through neutral: 7a Cut the neutral (white) lead from the crimp. Re-strip the neutral (white) lead to expose the proper length of conductor and connect it to the white or gray branch circuit neutral in accordance with local code using wire nuts. 7b Attach the appliance grounding lead (green or bare copper) in accordance with local codes. If the residence grounding conductor is aluminum, see WARNING note (see page 6). 7c Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see “WARNING” note (see page 6). Branch circuit Black Alternate knockout Range conduit snaps into box Red White Ground wires 7 Installation Instructions ELECTRICAL CONNECTIONS (CONT.) Do not shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junc...

Эта инструкция также подходит к моделям:
Музыкальные инструменты - JDS28 (331.08 kb)
Музыкальные инструменты - JDP39 (331.08 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории