Производитель: Follett
Размер: 957.91 kb
Название файла: b3d6dcab-1237-9204-c526-13f2bc0365b3.pdf
|
Фрагмент инструкции
Order parts online Serial numbers C45184 and above 2 Welcome to Follett Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that you take a moment to review this manual before beginning the installation. Should you have any questions or require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301. Before you begin After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the fi ling of a claim, if necessary. Specifi cations Series specifi cations FZR5-PL 34" height for freestanding use or installation below standard 36" (915mm) high counter 2 drawers - up to 40 (350ml) plasma cartons Maximum drawer load - 35 lbs (16kg) each. Electrical specifi cations 115V, 60Hz, 1 phase Full load amps: 8.0 Minimum circuit ampacity: 15 amp Maximum size of branch circuit overcurrent device: 15 amp Refrigeration specifi cations Refrigerant – R404A Charge size – 10 oz Maximum design pressures: High side – 383psi Low side – 175psi Installation specifi cations Ambient temperature must not exceed 30 C (86 F). The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the refrigeration system. Important cautions • Equipment must be wired according to local and NEC codes. • Always disconnect power before servicing freezer. 3 Fig. 1 Installation Installing legs – required 1. Remove legs from plastic bag packed inside freezer. 2. Tip freezer back and screw legs in all the way to stop (they will extend 1/8" below base of freezer). 3. Adjust legs as needed to level freezer in both directions. To access legs, remove the lower front panel. Turn legs clockwise to extend legs. Temperature surveillance module Follett’s all-in-one temperature alarm and chart recorder module (manufactured for Follett by Dickson) may be included with your FZR5-PL. Please refer to the Dickson instructions packed with this module for set-up and operation instructions. Follett’s monitoring bottle and temperature probe has already been installed in the Follett FZR5-PL. Simply connect the loose end of the probe wire on the back of the unit to the surveillance module to complete the install. A box of sixty (60) -50 to +50 7-day charts have also been included with this module. Replacement charts and pens can be ordered from Follett by calling Technical Service at 800-523-9361: Item # 00162099 — Box of sixty (60), -50 to +50, 7-day replacement charts Item # 00162081 — Box of six (6) replacement red pens Charts with different temperature scales are also available. Contact Dickson at 4 Reversing the door swing – optional Fig. 2 NOTICE When reinstalling latch and hinge screws, 242 blue Loctite* MUST be applied to screws. Torque screws to 25 in-lbs. 1. Remove screws and latch from refrigerator cabinet (Fig. 2.1). 2. Use flat screwdriver to carefully remove (do not scratch) hinge covers (Fig. 3.1). 3. Support door and remove screws attaching hinge to refrigerator cabinet (Fig. 3.2). 4. Cover hinge screw holes with screw hole plugs removed from opposite side. 5. Reverse door. Apply 242 blue Loctite to hinge screws and reinstall torqued to 25 in-lbs. 6. Reinstall latch on opposite side. 7. Remove screws and handle from door (Fig. 4.1). 8. Rotate handle (Fig. 4.2). 9. Apply 242 blue Loctite to latch screws and reinstall torqued to 25 in-lbs. 12 Fig. 3 12 Fig. 4 112 *Loctite is a registered trademark of Henkel Corporation in the United States and other countries. 5 Controller operation Fig. 5 In normal operation the controller displays cabinet temperatures in degrees C (default) or user-selected degrees F. The controller is pre-programmed with a -35 C (-31 F) set point which provides a compressor cut-in at -33 C (-27F) and cut-out at -35 C (-31 F). The controller set point can be raised to -25 C (-13 F) when a lower temperature is not desired. Follow instructions for changing temperature cut-out below. All set points have a 2 C differential. The 2 C differential means that with a -35 C set point, for example, the compressor will turn off at -35 C (-31 F) and turn on when the cabinet reaches -33 C (-27 F). °C - 35 evaporator fan energized defrost refrigeration system energized This temperature may not reflect the temperature of the blood products in the freezer. The temperature of the blood products will be reflected on the recorder chart and the recorder's digital temperature display. At times there may be a difference between the two displayed temperatures. Adjust the controller SET value to achieve your desired blood product temperature as displayed on your chart recorder. To display temperature cut-out STEP INPUT DISPLAY 1 Pr...