Производитель: AMX
Размер: 2.76 mb
Название файла: Modero.CV5.OperationReferenceGuide.pdf
|
Фрагмент инструкции
For a personal computer to establish a connection to a Modero panel via USB, the target computer must have the appropriate AMX USB driver installed. This installation is bundled into the latest TPDesign4 software setup process or can be downloaded independently from the main Application Files page on Step 1: Setup the Panel and PC for USB Communication 1. If you do not currently have the latest version of TPDesign4, navigate to > Tech Center > Downloadable Files > Application Files > NetLinx Design Tools section of the website and locate the AMX USB Driver executable (AMX USBLAN Setup exe). 2. Download this executable file to a known location on your computer. 3. Launch the Setup.exe and follow the on-screen prompts to complete the installation. Step 2: Confirm the Installation of the USB Driver on the PC The first time each AMX touch panel is connected to the PC it is detected as a new hardware device and the USBLAN driver becomes associated with it (panel specific). Each time thereafter the panel is "recognized" as a unique USBLAN device and the association to the driver is done in the background. When the panel is detected for the first time some user intervention is required during the association between panel and driver. 1. After the installation of the USB driver has been completed, confirm the proper installation of the large Type-A USB connector to the PC's USB port, and restart your machine. If the panel is already powered, continue with steps 3. The panel MUST be powered and configured for USB communication before connecting the mini-USB connector to the panel’s Program Port. 2. Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on the rear/side of the touch panel and then apply power. 3. After the CV5 panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds) to continue with the setup process and proceed to the Setup page. 4. Select Protected Setup > System Connection (located on the lower-left) to open the System Connection page (FIG. 32). FIG. 32 USB System Connection page - using a USB Connection Type No connection is established until the Virtual Master becomes active within Studio Red Connection Status icon indicates no connection to a Virtual Master Green Connection Status icon indicates communication to a Virtual Master 5. Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB. Refer to the System Settings Page section on page 68 for more information about the fields on this page. NXD-CV5 5" Modero Wall/Flush Mount Touch Panel Configuring Communication ALL fields are then greyed-out and read-only, but still display any previous network information. 6. Press the Back button on the touch panel to return to the Protected Setup page. 7. Press the on-screen Reboot button to both save any changes and restart the panel. Remember that the panel’s connection type must be set to USB prior to rebooting the panel and prior to inserting the USB connector. 8. ONLY AFTER the unit displays the first panel page, THEN insert the mini-USB connector into the Program Port on the panel. It may take a minute for the panel to detect the new connection and send a signal to the PC (indicated by a green System Connection icon). If this is your first time installing the USB driver, a USB driver installation popup window (FIG. 33) appears on the PC. FIG. 33 USB driver installation popup window .. This window notifies you that the panel has been detected by the PC as a USB-compliant device and the PC is installing an appropriate USB driver to establish a proper communication to the panel. .. This driver was installed on your PC during the installation of the latest NetLinx Studio and TPDesign4 software application installations. These applications should be installed prior to setting up a USB connection to the panel. .. The driver does not contain a Microsoft® digital signature and Windows® then informs you of such. 9. Click Yes when told that a digital signature was not found. This action accepts the installation of the new AMX USB driver. The panel is now configured to communicate directly with the PC. This process completes the association between driver and device. Each time the same touch panel is connected to the computer the driver is automatically loaded (using a unique name - example USB LAN LINK #1, #2). Each time a different touch panel is connected to the computer, the previous procedures will need to be repeated. 10. Navigate back to the System Connection page. NXD-CV5 5" Modero Wall/Flush Mount Touch Panel Configuring Communication Step 3: Confirm and View the current AMX USB device connections The USB driver information can be confirmed via two different methods: .. Via the Control panel (previous steps 1 and 2) or .. Via the Unplug or Eject Hardware icon from the Taskbar. 1. Navigate to Start > Settings > Control Panel > and double-click the System icon to launch the System ...