Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Samsung, модель 460PX

Производитель: Samsung
Размер: 7.4 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


When adding an account, you can select from among three account types, and the selected account type decides the scope of using MagicNet. You may modify or delete the accounts of existing users as well as adding new users. Account Type Scope Administrator Power User Operator You have the authority to use all MagicNet functions. You are not authorized to use the Options menu and the Update function of MagicNet. You are not authorized to use the right mouse button click in the Library Registration, Options menu, MDC and Monitor List from among the MagicNet functions. • User Name • Password Change Password You can change your password in the login status. Enter your password correctly before logging in. You will be prompted to enter the password for installing MagicNet, and this password will become the default password for the administrator account. If you forget the password, please remove the program and re-install it. • Old Password • New Password • Confirm Password Option 1. Server Name In the Options, you can specify the server name for the connection information. The servers and monitors are connected via the network, and have proper names to identify each other. For a normal connection, the server name between a server and monitor must match. In other words, when the name of a server is MagicNet, only monitors whose server names are set to "MagicNet" can be connected to that server and receive the schedule. When there is no server with that name set in the monitor, it will wait until a server that matches this name appears. However, when the auto connction function is ON, it tries to connect to any server, and will connect to the server that replies first. • Server Name 2. User Account When installing MagicNet for the first time, the administrator account is provided on the basis of the password entered by the user. When adding an account, select from among three account types, and the selected account type decides the scope of using MagicNet. You may modify or delete the accounts of existing users as well as adding new users. Account Type Scope Administrator You have the authority to use all functions of MagicNet. Power User You are not authorized to use the Options menu and the Update function from among the MagicNet functions Operator You are not authorized to use the right mouse button click in the Library Registration, Options menu, MDC and Monitor List from among the MagicNet functions. • Create • Modify • Delete 3. File Download If the monitor is turned off at the scheduled download time, the system tries to turn on the monitor and starts the download if the monitor is turned on within 3 minutes. Otherwise, the download will be canceled. 1) Displays a list of the settings for downloading files to the monitor or deleting files. (Displays the list for the currently connected monitor.) 2) Allows you to set the time for downloading files to the monitor or deleting files. 3) Allows you to specify the device and folder to which the downloaded files are saved. 4) Allows you to select the files from a server computer you want to download to your monitor. 5) Allows you to select the files you want to delete from your monitor. 6) Allows you to confirm and change the current download and deletion file selections. 4. Network Device You can select a network device connected to the monitor. This is useful, especially if there are multiple devices running on the PC. • Select a network device connecting to a monitor. 5. Monitor Update You can update multiple monitors at the same time. This is useful when needing to update multiple monitors at the same time. When selecting a file to update and the update utility file (NK.bin) and clicking Update, the update process is done in two steps. Download (stores the update file on the monitor) > Update (installs MagicNet). When done, the monitor restarts automatically. If an error (wrong file) is detected during this process, a warning message appears and the update process stops. When the download is completed, make sure to keep the monitor turned on during the update. And, if the output source is a PC, make sure the monitor-off function, if any, of the PC is not activated. Otherwise MagicNet may not operate properly. If the monitor turns off during the update process, contact our customer service. For SyncMaster 320PXn/400P(T)Xn/460PXn, see Add/Remove Programs. • Choose a monitor and file to update. 6. Monitor Model If the monitor to the server is changed to SyncMaster 460Pn/400Pn, SyncMaster 320PXn/400P(T) Xn/460PXn, SyncMaster 711ND or an integral model (mixed type), the server will be adjusted according to the model. Note that the supportable file formats, MDC and message-related functions will vary depending on the selected monitor model. • SyncMaster 400Pn/460Pn • SyncMaster 711ND • SyncMaster 400TXn • SyncMaster 320PXn/400PXn/460PXn • Combination 7. Save Schedule Allows you to save all the schedules registered on all monitors to a server database. If you shutdown...

Эта инструкция также подходит к моделям:
Мониторы - 400PX (7.4 mb)
Мониторы - 400PXN (7.4 mb)
Мониторы - 460PXN (7.4 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории