Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Samsung, модель 400P

Производитель: Samsung
Размер: 4.54 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


2. First, select the monitor to apply in the client list window. 3. If you choose All Monitors, all monitors will be selected. 4. If you try to run the detailed functions for each tab without first selecting a monitor, a warning message will appear. 5. After selecting a monitor, click each MDC tab to run the detailed functions. In this case, when running menus that cannot be adjusted in the output source, the warning 'Adjustment unavailable' will appear. Furthermore, when running adjustable menus, the selected values will be applied to the monitor, and the results will be applied to the MDC status window. If not applied to the monitor, it will also not be applied to the MDC status window. The MDC functions comply with the specifications for running the monitor. MDC OSD Power Source Image Time PIP Settings Maintenanace Power Select Power ON/OFF. • ON • OFF When changing the volume, the changed details will appear in an OSD on the monitor screen. • 0 ~ 100 Source In the source tab, the output source of the monitor can be changed. When selecting the following output source, it will change to the relevant output source. When the relevant device is not connected, a screen with 'Connection required' will appear. • PC • BNC • DVI • AV • S-Video • Component • MagicNet Image 1. Image Size The size of the current output screen with output sources other than PC signals is adjustable. When selecting the menu below, it will be changed to the selected size. • 16:9 • Panorama • Zoom1 • Zoom2 • 4:3 2. Image Size PC Adjusts the output screen size of the PC signal. When trying to change the size of non-adjustable input sources, a warning message will appear on the monitor. • 16:9 • 4:3 Time 1. Current Time Establishes the standard time of the monitor. In Hours, Minutes and AM/PM, select the time, and click the Apply button. The current standard time of the monitor will be set. To activate the On/Off Timer at the set time, the Current Time must be set. • Hours • Minutes • AM/PM 2. On Timer Select the time, output source and volume, and click the Apply button. The monitor will turn on with the established source and volume at the established time. When Activated is OFF, the ON Timer will not work. • Hours • Minutes • AM/PM • Activated • Source • Volume 3. Off Timer Select the time and click the Apply button. The monitor will turn off at the set time. When Activated is OFF, the Off Timer will not work. • Hours • Minutes • AM/PM • Activated PIP 1. Size Select a size. (The size selection has an 'ON' function) 2. Source When selecting sources to be output to PIP, the relevant source will be applied to PIP. When trying to change a source where PIP cannot be applied or the combination of Main/Sub is incompatible, a warning message will appear on the monitor. Settings 1. Picture For input sources other than for PC signals, adjust the Contrast, Brightness, Sharpness, Color, Tint and Color Tone of the monitor. • Contrast • Brightness • Sharpness • Color • Tint • Color Tone 2. Picture PC When the output sources are PC signals, adjust the Contrast, Brightness, Sharpness, Color, Tint and Color Tone of the monitor. • Contrast • Brightness • Red • Green • Blue 3. Audio Adjust the Bass, Treble and Balance, and set Main/Sub for the Sound Select of Dolby Virtual ON/OFF, BBE ON/OFF and PIP. In the course of making adjustments, changes appear as OSDs on the monitor screen. • Bass • Treble • Balance • Dolby Virtual • BBE • Sound Select 4. Adjust Image Lock Course, Fine, and select Position. • Coarse • Fine • Position • Auto Adjustment Maintenance 1. Lamp Control You can control the intensity of the lamp. (Auto/Manual is available. When Auto is running, Manual is off; and when Manual is running, Auto is off.) In Auto mode, the lamp is adjusted to the previously set value at the set time. In Manual, the previous value is maintained. • Auto • Hours • Minutes • AM/PM • Value • Manual 2. Scroll This function prevents the screen status changing when the same screen is maintained continuously. If you select the Period and Time and press the Apply button, the screen will scroll downwards at the speed of the previously set time in Period. For example, for Period 1, Time 5, the screen will be renewed every hour at a speed of 5 seconds. • Period • Time 3. Video Wall This offers a function that enables you to use several monitors as one screen. First, select the button that sets the number of monitors to be used and their allocation. The allocation figure will appear as a selectable button on the side. For example, when you choose 2*2, selectable buttons in the form of 2 rows and 2 lines appear, and if you select number 3 in this matrix, the third screen of the output screen divided by 4 will show up in the monitor. • 2*2 • 3*3 • 4*4 • 1*5 • 5*1 • OFF • Format Introduction to Schedule MDC Upper Remote Control Removing | | | | | | Troubleshooting | Specifications MagicNet OSD Adjustment Menu Adjustment Program Upper Menu Login / Logout Change Password Options...

Эта инструкция также подходит к моделям:
Мониторы - 400PN (4.54 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории