Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Alto-Shaam, модель 52C3KSA -2

Производитель: Alto-Shaam
Размер: 368.44 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Max. thrust of spray handle and lance - see section 1.2 Technical data. Operating instructions US 4. Detergents If you want to apply detergents or disinfectants these can be metered through an accessory injector. Below you will find various types of outlet points with injectors. Outlet point with detachable injector To be attached to the quick coupling of the high pressure cock. To be used for dosing of low-foaming detergents or disinfectants. Metering range 1-8%. Outlet point with detachable foam injector To be attached to the quick coupling of the high pressure cock. To be used in conjunction with foam lance for application of high-foaming detergents or disinfectants. Metering range 1-5%. Cleaning cart with foam injector and reel To be attached to the quick coupling of the high pressure cock. To be used in the same way as „Outlet point with detachable foam injector“. Makes it possible to carry 4 spray lances, 2-6 gallon containers and 66 ft. of high pressure hose. Outlet point with built-in injector and regulation of water volume (only KSA-2) Fixed to the pipeline. Allows the operator to regulate the discharge water volume from 2.4 gpm to full volume, with or without the metering of detergents or disinfectants. Metering range 1-12%. Operating instructions US 4.2 Starting Check that the oil level in the oil reservoir(s) (2) is between the MIN. and MAX. markings. The inlet water shut-off cock should be open. NOTE: The system automatically stops after approx. 4 seconds if there is no water consumption. In the event of a power failure or activation of the thermal switch (with subsequent cooling) the system can be restarted from pos. 0. Check oil level Turn to „Start“ position C3KSA-1 O Start 1 KSA-1: Turn the red start/stop knob (1) to position „Start“ (it’s spring-loaded and when released, it will return to position 1 = operation). Watch the pressure gauge (3) to see that pressure is being built up in the system when activating the trigger of the spray handle, on which a spray lance set for high pressure is attached. If pressure does not build, vent the machine as described in section 3.4 Venting. C3KSA-2 2 1+2 O 1 Check oil level Turn to: Position 1 = Pump no. 1 in operation Position 2 = Pump no. 2 in operation Position 1+2 = Pumps no. 1 & 2 in operation KSA-2: Turn the red start/stop knob (1) to position 1, 2 or 1+2. Ensure that pressure is building in the system by watching the pressure gauge (3). If pressure is not being built, vent the machine as described in section 3.4 Venting. 4.3 Operation - automatic start/stop Always hold the spray lance with both hands! Always lock the trigger when the machine is not in operation. Once started, the system will automatically re-start when the spray handle trigger (1) is activated. When the trigger is released, the system automatically stops after approx. 4 seconds. When the machine is not in use, the trigger should be locked by turning the safety knob (2) into position 0. Operating instructions US Turn spray lance pressure reducing valve (1): Clockwise (B): high pressure Counter clockwise (A): low pressure/ detergent application The spray lance employs a high pressure nozzle and a low pressure nozzle. On KSA-1 pump systems the water volume is adjusted on the water regulation valve of the pump (2). High pressure mode The max. working pressure of the machine is reached when the pressure reducing valve (1) is completely closed (B), and the water regulation valve (2) is fully counter-clockwise. In this position only the high pressure nozzle is used - high pressure mode. The water volume is infinitely variable (2) between min. and max. output. Reduced water volume = reduced pressure. With the trigger released, turn the water regulation valve (2) to adjust volume and pressure (clockwise = Lower volume and pressure). Minimum volume results in a working pressure of 580 psi through the high pressure nozzle (only), and a water volume of approx. 2.4 gpm. If you want more water volume, the valve (2) should be turned counter-clockwise until the desired result is achieved. 1 turn provides change of approx. 725 psi. Low pressure mode When the reducing valve (1) is completely opened (A), the pressure will be fully reduced. The nozzle pressure will be approx. 60 psi. In this position both spray nozzles are used - low pressure mode / possibility of dosing detergents. 4.5 Double spray lance, regulation of pressure - KSA-2 MULTIPRESSURE P PSI Q GPM CN 390 3.7 White 1 Turn pressure reducing valve: 390 7.7 Black 2 720 3.7 Brown 1 Clockwise (B): high pressure 770 7.3 Green 2 1160 3.7 Blue 1 1160 5.9 Red 2 Counter clockwise (A): low pressure/ 1550 3.7 Orange 1 addition of detergents 1550 5.7 Yellow 2 2200 3.7 Steel 1 4.4 Double spray lance, regulation of pressure and water volume - KSA-1 The spray lance features a high pressure nozzle and a low pressure nozzle. When the pressure reducing valve (1) is completely closed (B) only the high pressure nozzle is used - high pressure mode. W...

Эта инструкция также подходит к моделям:
Моечное оборудование - 52C3KSA -1 (368.44 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории