Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации DeWalt, модель DP2800

Производитель: DeWalt
Размер: 4.33 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


The thermal relief valve will then close. If pump is left in bypass mode for more than two minutes internal components of the pump can be damaged. Start-up Procedure 1. In a well-ventilated outdoor area, add fresh, high-quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to engine instruction manual for correct procedure. 2 . Check engine oil level. Refer to the engine instruction manual for correct procedure. 3. Connect the water hose to the water source. Turn the water source on to remove all air from the hose. When a steady stream of water is present, turn the water source off. 4. Verify the filter screen (U) is in water inlet of U pump. The cone side faces out. 5. Connect the cold water source (V) to pump inlet. NOTE : Water source must provide a minimum of 5 gallons per minute at 20 pSI. Warning : To reduce the possibility of contamination always protect against backflow when connected to a potable water system. 6. Connect high-pressure hose (C) to pump V outlet. c 7. If applying a chemical or cleaning solution, refer to Chemicals and Cleaning Solvents. 8. Turn the water source on. Ca ution: Risk of property damage. Failure to do so could cause damage to the pump. 9. Remove all air from the pump and high pressure hose by depressing trigger until a steady stream of water is present. 10. Start engine. Refer to the engine instruction manual for correct procedure. Warning : Risk of unsafe operation. If engine does not start after two pulls, squeeze trigger of gun to relieve pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to avoid kickback and prevent hand or arm injury. 11. Depress trigger on gun to start water flow. Warning : Risk of unsafe operation. Stand on a stable surface and grip gun/wand firmly with both hands. Expect the gun to kickback when triggered. 12. Release trigger to stop water flow. DANGER: Risk of injury from spray. Engage the trigger lock (W) when gun is not in use to prevent accidental spraying. 13. Adjust spray for the task being performed by changing quick connect nozzle. Refer to Spray Wand Nozzles. Shutting Down 1. If chemicals were applied, place the chemical hose into a container of clean water and draw clean water through chemical injection system to rinse system thoroughly. W cAutIoN: Risk of property damage Failure to do so could cause damage to the pump. . Turn engine off. Refer to the engine instruction manual. cAutIoN: Risk of property damage. NEvER turn water supply off while pressure washer engine is running or damage to pump will result. 3. Turn water source off. 4. Pull trigger on spray gun to relieve any water pressure in hose or spray gun. 5. Refer to storage for proper storage procedures. MAInTEnAncE WARNING: Risk of burning. When performing maintenance, you may be exposed to hot surfaces, water pressure or moving parts that can cause serious injury or death. WARNING: Risk of fire. Always disconnect, spark plug wire, let the engine cool and release all water pressure before performing any maintenance or repair. The engine contains flammable fuel. Do not smoke or work near open flames while performing maintenance. To ensure efficient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. If the pressure washer is used in unusual conditions, such as high temperatures or dusty conditions, more frequent maintenance checks will be required. Engine Consult the engine instruction manual for the manufacturer's recommendations for any and all maintenance. note: The pressure washer frame is equipped with an oil drain hole to help make changing the engine oil easier. Pump note: The pump was filled with oil at the factory. 1. Change pump oil after the first 10 hours of operation and every 50 hours thereafter. to cHeck oIL 1. The oil level should come to the dot in the middle of the sight glass (X). HoW to cHanGe PuMP oIL 1. Loosen pump oil fill plug (H). . Place a container under the oil drain plug (Y). 3. Remove pump oil drain plug. 4. After oil is drained, replace oil drain H Y X English plug. Tighten securely. 5. Remove pump oil plug and fill with 8.5 oz. ( 51 ml) of DP70 pump oil. If DP70 is not available use 30W non-detergent oil. 6. Replace pump oil plug and tighten securely. nozzle cleaning If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions: 1. Shut off the pressure washer and turn off the water supply. . Pull trigger on gun handle to relieve any water pressure. 13 English 3. Disconnect the spray wand from the gun. 4. Remove the high-pressure nozzle from the spray wand. Remove any obstructions with the nozzle cleaning tool (Z) provided and back flush with clean w...

Эта инструкция также подходит к моделям:
Моечное оборудование - A16505 (4.33 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории