(No polarity) • For address setup, refer to the Installation Manual supplied with the outdoor unit. Setup data Detection temp shift value 0000 No shift 0001 +1° C 0002 +2° C (At shipment from factory) 0003 +3° C 0004 +4° C 0005 +5° C 0006 +6° C 8TEST RUN In case of wireless remote 30 NOTE Do not use a forced operation in cases other than test operation because it applies an excessive load onto the air conditioner. In case of wired remote controller 1, 5 3 2, 4ON / OFF FAN TEMP. SWING/FIXTIME MODE VENT UNITSET CL FILTER RESET TEST TIMER SET How to execute test operation • To carry out a fan operation in a single indoor unit, firstly turn off the power found on the P.C. board. Once completed turn the power to the unit back Upon completion of the test do not forget to remove the short circuit on CN72. • Using the remote controller, check the unit is in normal operation. For the operation supplied Owner’s Manual. A forced test operation can be executed in the following procedure under of thermo.-OFF of room temperature. In order to prevent the test operation from running continuously, the operation will cease 60 minutes. The unit will then return back to its original operation. Before test operation • Before turning on the power supply, procedures. 1) Using 500V-megger, check there is 1M. or more between the terminal block of the power supply and the earth. If 1M. or less is detected, do not run the unit. 2) Check that all the valves of the outdoor unit are fully WARNING To protect the compressor at startup. Ensure the power supply is left on for 12 or more hours before operation. • Never push the electromagnetic contactor to carry out (It is very dangerous because a protective device does not Procedure Description 1 Keep the TEST button pushed down for 4 seconds or more. [TEST] is displayed on the display part and the selection of the test mode is permitted. TEST 2 Push ON / OFF button. 3 Using MODE button, select the operation mode, [COOL] or [HEAT]. • Do not run the air conditioner in a mode other than [COOL] or [HEAT]. • The temperature controlling function will not work during the test operation. • Fault detection will perform as usual. 4 After the test operation, push the ON / OFF button to stop the operation. (Display part is the same as procedure 1) 5 Push the TEST button to cancel (release from) the test operation mode. ([TEST] disappears on the display part and the status returns to normal.) Procedure Description 1 Remove a small screw which fixes the nameplate Remove the nameplate of the sensor section by inserting of the plate, and set the Dip switch to [TEST RUN ON]. 2 Execute a test operation with button on the wireless remote controller. • , , and LED flash during test operation. • Under status of [TEST RUN ON], the temperature adjustment from Do not use this metho...
Эта инструкция также подходит к моделям:Магнитолы - MMU-AP0091MH (3.52 mb)
Магнитолы - MMU-AP0181MH (3.52 mb)
Магнитолы - MMU-AP0151MH (3.52 mb)
Магнитолы - MMU-AP0121MH (3.52 mb)