Производитель: FrancisFrancis
Размер: 1.6 mb
Название файла: 0a7b5596-effb-47db-970e-1cf8e03761aa.pdf
|
Фрагмент инструкции
For your future reference please keep this manual in a safe place. Thank you for specifying a product from the Francis Searchlights range. All Francis products are designed to give complete customer satisfaction and are manufactured to the highest engineering standards in order to ensure optimum performance and service life. The Francis Xenon range combine features proven over many years service in the most hazardous conditions in both marine and land installations. In order to prolong the life and performance of your product, we recommend that you only specify Francis Searchlights spare parts. This will also ensure that any warranties on your equipment will not be invalidated. Information on spares ordering and parts is provided in this manual. Should you ever need to contact Francis Searchlights Ltd. regarding your equipment, please quote the Product Serial Number at all times. Back To Top 2 - Safety Precautions The following instructions must be adhered to, in order to ensure a safe working environment and the safety of the user. Note: When unpacking or manoeuvring the searchlight into its fixing position, suitable lifting points must be used in order to prevent damage to the equipment or personal injury. Because of the high internal pressure within the lamp, there is a risk of explosion in either a hot or cold state; During operation this lamp emits intense UV radiation which is harmful to the eyes and skin. Suitable protection should be worn; The high luminance of the arc can cause severe damage to the eye if viewed directly. ALWAYS wear suitable protective goggles when viewing the lamp; Always use protective jackets supplied with the lamp; Should it be necessary to examine the lamp with the front bezel removed, always use a protective shield and wear goggles to ensure a safe working environment; Searchlights get hot. Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the searchlight off; Never place anything on or cover the searchlight when in use; Ensure the lamp has cooled sufficiently before removal; If undue force appears necessary to remove the lamp, the equipment should be inspected by a competent person or contact the manufacturer; When disposing of lamps there are several options available: Return the lamp, via the supplier, to the lamp manufacturer in its complete packaging Because of the cold internal pressure of the lamp is approximately 8 bar, the lamp must first be depressurized before disposal. Place the lamp, in its protective jacket, in a plastic bag and drop from a height of 1 to 2 metres onto a hard surface; XBO lamps do not contain materials which are harmful to the environment and thus are not subject to special waste disposal regulations; Due to the vast range of lamps available it may appear possible that more powerful lamps can be used in the equipment than for which it was designed. Even when the unit will physically accept a higher wattage lamp, this substitution is not recommended and is dangerous. This action will also void any warranties on the equipment. Always refer to the lamp manufacturers technical data when dealing with lamps. Back To Top 3 - Technical Information This product has been designed to operate in accordance with the product specification. The FX560RC 2000 watt searchlight has the following features: All marine grade materials and fixings; Electronic power supply unit; Parabolic glass reflector; Stove enamel painted; 385° horizontal rotation; Vertical movement 20° to -20°; Motor speed 0-20°/sec fast, 0-10°/sec slow (Pan) 0-10°/sec fast, 0-5°/sec slow (Tilt); Remote focus facility; Internal self-regulating heater. The searchlight also performs to the following optical data: Xenon light source; Lamp Wattage - 2000 Watts; Supply voltage – 110/120v or 220/240V; Peak Beam Candlepower – 108,084,800 lux; Range – 10,396 metres; Divergence - 1.5°; Temperature range: -50°C; In order that the searchlight operates correctly it is imperative that competent personnel are responsible for the installation, operation and servicing of this equipment. Failure to adhere to this advice may cause premature failure or incorrect operation of the searchlight, which may damage the equipment or cause personal injury. Technical information on the Xelamp Power Supply Unit and Irem Ignitor are included overleaf. For more detailed information please contact the manufacturer. PSU ref: Model 8502 (Xelamp) Ignitor ref: AS16040A (Irem) Power Supply fixings centres 440 x 152 using M8 screws. Power Supply Details (Model 8502) General Description Output Power 1400-2200 watts Voltage 22-30 volts D.C. Current 50-85 amperes D.C. Ripple 5% peak-to-peak Input Current 25/22 amperes maximum 40 amperes maximum Voltage 208/237 VAC 110/120 VAC Phase Single Frequency 60 Hz (50Hz available) Output Adjustments 9 steps Size Width 12” (30.5 cm) Height 15” (38 cm) Length 19” (48.25 cm) Weight 145 lbs. (65.9 Kg) Cooling Convection Warning When this appears in this tex...