Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Kenwood, модель TH-22A

Производитель: Kenwood
Размер: 2.05 mb
Название файла: ab48e697-a308-472c-b99e-c3e795a66bc8.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Refer to page 50 for identification of the microphone PF keys and further information. 17 UNLOCKING ENC/SQL CONTROL If you only want to lock the keys but not the ENC/SQL control when Key Lock is activated, that is possible too. 1 Press [CALL] + POWER ON to select Menu Set-up. 2 Turn the ENC/SQL control to select Menu No. 06. • The current status of ENC/SQL control lock appears. • The default is "OFF". 3 Press [CALL] to select "ON" or "OFF". • OFF: Locks ENC/SQL control with keys. * ON : Does not lock ENC/SQL control with keys. 4 Press any key other than [CALL], [LAMP], or [MONI] to exit Menu Set-up. 18 BEEP TONE ON/OFF The transceiver beeps each time you press a key on the transceiver with the exception of [MONI], [LAMP], and [PTT]. Pressing [PTT] generates a beep if your transmit frequency is outside the transmit band. Beep volume can be varied by turning the PWR/VOL control. If you prefer, you can cancel the beep for silent operation. 1 Press [CALLJ+ POWER ON to enter Menu Set-up. 2 Turn the ENC/SQL control to select Menu No. 04. • The current beep status appears. * The default is "ON". 3 Press [CALL] to select "OFF" or "ON". * OFF: Disabfes Keypad Beep. • ON : Enables Keypad Beep. 4 Press any key other than [CALL], [LAMP], or [MONI] to exit Menu Set-up. Nofe.- When Tone Alert is switched ON while the Beep function is OFF, an audible alarm does not sound when a signal Is received. TRANSMITTING SELECTING OUTPUT POWER It’s wise, and required by law, to select the lowest power that allows reliable communication. This saves battery power which extends battery life, and lowers the risk of interfering with others on the band. Press [F], [PTT]. • The default is High power (no indicator appears). • Each time this key combination is pressed, the transmit output power changes as below: High -Low ("L") - Economic Low ("EL") Batteries High n "EL" PB-30 1.8 W 0.5 W 0.05 W 1 PB-32/33 3.0 W 2 0.5 W 0.05 W 1 PB-34 5.0'W 0.5 W 0.05 W 1 Alkaline 1.5 W 0.5 W 0.05 W 1 Manganese 1.5 W 0.5 W 0.05 W i 1 TH-42A/AT/E: 0.03 W 2 TH-42A/AT/E: 2.5 W Note: ► The transmit output power cannot be changed while transmitting. The horizontal bars that appear on the display while transmitting indicate the relative battery level. TIME-OUT TIMER (TOT) It is sometimes necessary or desirable to restrict a single transmission to a specific maximum time. This feature can be useful when accessing repeaters to prevent repeater time-outs, or when particularly trying to conserve battery power. Select the most appropriate timer value for your operating habits. 1 Press [CALL] + POWER ON to select Menu Set-up. 2 Turn the ENC/SQL control to select Menu No. 13. • The current timer value appears. * The default is " 900". . nUiifi tuJUU 3 Press [CALL] repeatedly to cycle through the timer values available. • You can choose 30 s, 60 s, 90 s, 180 s, or 900 s. 4 Press any key other than [CALL], [LAMP], or [MONI] to exit Menu Set-up. When TOT times out, the transceiver automatically returns to Receive. To resume transmitting, release and then press [PTT] again. 19 INHIBITING THE TRANSMITTER The transmit function can be disabled to prevent unauthorized individuals from transmitting, or to eliminate the risk of yourself accidentally transmitting. 1 Press [CALL] + POWER ON to select Menu Set-up. 2 Turn the ENC/SQL control to select Menu No. 05. • The current Transmit Inhibit status appears. * The default is "OFF". APO , r**CC /K t bU1 ' u-) 3 Press [CALL] to select "OFF" or "ON". • OFF: Enables transmitter ("TX.S" disappears). • ON : Inhibits transmitter ("TX.S" appears). 4 Press any key other than [CALL], [LAMP], or [MON!] to exit Menu Set-up. If [PTT] is pressed while Transmit Inhibit is ON, your transceiver beeps and will not transmit. The PTT switch on any microphone configured for remote control with this transceiver also will be disabled. On TH-22E/TH-42E versions, the 1750 Hz tone cannot be transmitted while Transmit Inhibit is activated. 20 BUSY FREQUENCY LOCK-OUT A method of inhibiting the transmitter when the current receive frequency is busy, is provided. This feature can help to eliminate "doubling" (simultaneous transmissions) with other stations. 1 Press [CALL] + POWER ON to enter Menu Set-up. 2 Turn the ENC/SQL control to select Menu No. 14. • The current Busy Frequency Lock-out status appears. • The default is'’OFF'1. 3 Press [CALL] to select "OFF" or "ON". • OFF: Enables transmitter on a busy frequency. * ON : Inhibits transmitter on a busy frequency. 4 Press any key other than [CALL], [LAMP], or [MONI] to exit Menu Set-up. MEMORY CHANNELS A total of 40 memory channels (0 to 39) are available for storing frequencies and related data. Each memory channel can be used either as a simplex channel or split channel. Alternatively, a standard or non-standard frequency offset and offset direction required for using repeaters can be stored. Refer to "OPERATING THROUGH REPEAT...

Эта инструкция также подходит к моделям:
Лодочное оборудование - TH-22E (2.05 mb)
Лодочное оборудование - TH-42A (2.05 mb)
Лодочное оборудование - TH-42A/42AT/42E (2.05 mb)
Лодочное оборудование - TH-42AT (2.05 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории