Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Iomega, модель PROCESS / STRAIN GAUGE CONTROLLER CNIS32

Производитель: Iomega
Размер: 649.37 kb
Название файла: MQS3536.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


0 AL2.H=200 AL1.H=400 Example 2: Output 1: Relay, Set Point 1 = 200, Output 2: Relay, Set Point 2 = 200 Alarm 1 setup: Deviation, Band, "ALR.H" = 20 Alarm 2 setup: Deviation, Hi/Low, "ALR.H = 10", "ALR.L = 5" Color Display setup: "N.CLR"=Green, "1.CLR"=Amber, "2.CLR"=Red Display colors change sequences: AMBER | RED | GREEN | GREEN | RED | AMBER •-.--------•----------•--------------•--------------•----------•------------. 0 180 195 200 210 220 READING CONFIGURATION SETUP (operation example) Below is a flowchart showing how to navigate through the submenus of the Reading Configuration menu item by pressing the front buttons. † Where: CALC/VALUE = Calculated input based on the transducer specification [Without Known Loads (DSBL)] ACT/VALUE = Actual signal being received [Known Loads (ENBL)] † MQS3536/1204 SPECIFICATION Accuracy: 0.03% rdg. Resolution: 10 / 1 .V process Linearization Points: 10 points Temperature Stability: 50 ppm/°C process Display: 4-digit, 9-segment LED, 10.2 mm (0.40") with red, green and amber programmable colors Input Types: Analog Voltage and Current Voltage: 0 to 100 mV, 0 to 1 V (+100 mV), 0 to 10 Vdc Input Impedance: 10 M. for 100 mV 1 M. for 1 or 10 Vdc Current: 0 to 20 mA(5 . load) Output 1: Relay 250 Vac @ 3 AResistive Load, SSR, Pulse, Analog Voltage and Current Output 2: Relay 250 Vac @ 3 AResistive Load, SSR, Pulse Options: Communication RS-232 / RS-485 or Excitation: 5 Vdc @ 40 mA, 10 Vdc @ 60 mA Exc. not available for Low Power Option Line Voltage/Power: 90 - 240 Vac ±10%, 50 - 400 Hz*, or 110 - 375 Vdc, 4 W * No CE compliance above 60 Hz Low Voltage Power Option: 12 - 36 Vdc, 3 W** ** Units can be powered safely with 24 Vac but No Certification for CE/UL are claimed. Dimensions: 25.4 H x 48 W x 126.3 D mm (1.0 x 1.89 x 5") Weight: 127 g (0.28 lb) Approvals: UL, C-UL, CE per EN61010-1:2001 d b • • • b d d d b b b d d b • • • b d d b d d d d bc d d d d d d d d • • • • • • • • a a a bc bc bc bc bc WARRANTY/DISCLAIMER OMEGAENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will extend the warranty period for four (4) additional years if the warranty card enclosed with each instrument is returned to OMEGA. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGAis not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGAassumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории