Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Eagle Group, модель 168EX

Производитель: Eagle Group
Размер: 3.52 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


feature must be turned on for fish alarms to work. To turn Fish I.D. on, press MENU until the FISH ID menu appears. Press UP ARROW to select ON, then press PWR. Then, press MENU until the FISH ALARM menu appears. Press UP ARROW to select ON, then press PWR. To turn off the fish alarm without turning off fish symbols, press MENU DOWN until FISH ALARM appears. Press DOWN ARROW to select OFF, then 45 press PWR to clear the menu. Repeat the above steps to turn the alarm back on, but press UP ARROW to select ON before clearing the menu. Depth Alarms The depth alarms are triggered only by the bottom signal. No other echoes will activate these alarms. The depth alarms consist of a shallow and a deep alarm. The shallow alarm sounds an alarm tone when the bottom goes shallower than the alarm's setting. The deep alarm sounds a tone when the bottom goes deeper than its setting. Both alarms adjust the same way, although through different menus. Shallow Alarm To set the shallow alarm depth, press MENU DOWN repeatedly until SHALLOW ALARM appears. Press UP ARROW to increase the shallow alarm's depth setting or press DOWN ARROW to decrease it. The number in the shallow alarm’s menu box shows the current shallow alarm setting. When the number reaches the desired setting, press PWR to clear the menu. When the bottom depth goes shallower than the alarm’s setting, an alarm tone sounds and a message box appears on the screen. Press PWR to silence the alarm. This turns the alarm sound off until the shallow alarm is triggered again. To turn the alarm off, press MENU DOWN repeatedly until SHALLOW ALARM appears. Press DOWN ARROW until the words OFF FEET appear, then press PWR to clear the menu. Deep Alarm To set the deep alarm depth, press MENU DOWN repeatedly until DEEP ALARM appears. Press UP ARROW to increase the deep alarm's depth setting or press DOWN ARROW to decrease it. The number in the deep alarm’s menu box shows the current deep alarm 46 setting. When the number reaches the desired setting, press PWR to clear the menu. When the bottom depth goes deeper than the alarm’s setting, an alarm tone sounds and a message box appears on the screen. Press PWR to silence the alarm. This turns the alarm sound off until the deep alarm is triggered again. To turn the alarm off, press MENU DOWN repeatedly until DEEP ALARM appears. Press DOWN ARROW until the words OFF FEET appear, then press PWR to clear the menu. DISPLAY ADJUSTMENTS BACKLIGHTS The display is backlit for night use. To turn the backlight on or off, press MENU repeatedly until the BACK LIGHT menu appears. Press UP ARROW to turn the light on or the DOWN ARROW to turn it off. DISPLAY CONTRAST The unit’s display contrast is adjustable to suit different lighting conditions. This will help you see the screen from different angles or at various times of the day. The default setting is min (minimum) percent. To adjust the contrast, press MENU DOWN until the DISPLAY CONTRAST menu appears. To decrease screen contrast, press the DOWN ARROW key. Press the UP ARROW key to increase screen contrast. The bar graph in the Contrast menu box shows a graph of the contrast. The screen will also show the effects of the change. If you reach the maximum or minimum level, a tone sounds alerting you to the limits. Press the PWR key to clear the menu. 47 DEPTH UNITS OF MEASURE This unit can show the depth in feet or meters. To change the depth units of measure, press MENU DOWN until the UNITS menu appears. Use the arrow keys to select the desired unit of measure, then press the PWR key to clear the menu. PRESET UNIT (reset all options) This command is used to reset all features, options and settings to their original factory defaults. This is useful when you have changed several settings and want to return the unit to basic automatic operation. Turn the unit off. Press and hold the DOWN ARROW key and the MENU DOWN key at the same time while you press the PWR key. Release the keys as the unit powers up. The unit will turn on with factory settings restored. SYSTEM INFO To show the operating software system information, press MENU DOWN until the UNIT INFO menu appears. Press PWR to clear the screen. SIMULATOR This unit has a built-in simulator that shows a simulated bottom signal with fish signals. This lets you practice with the unit as if you were on the water; all features and functions of the unit are usable. A message appears occasionally to remind you that the simulator is on. To use the simulator, press MENU DOWN repeatedly until the SIMULATOR menu appears. Press UP ARROW to turn it on, and press PWR to clear the menu. Repeat the above steps to turn it off, or you can simply turn the unit off and back on again. 48 DIGITAL DATA SIZE FOR DEPTH and TEMPERATURE The size of the digital numbers for the depth be changed to medium or large. The digital display for both Depth and Temperature can also be turned off or on. To change either of these options, press MENU DOWN until either the DEPTH SIZE or T...

Эта инструкция также подходит к моделям:
Лодочное оборудование - 168 (3.52 mb)
Лодочное оборудование - 128 (3.52 mb)
Лодочное оборудование - 128 PORTABLE (3.52 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории