Войти:
Оценок - 5, средний балл: 3.6 ( )

Инструкция по эксплуатации Furuno, модель 2127-BB

Производитель: Furuno
Размер: 5.81 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Flat washer Cable gland Vinyl sheath Clamping gland Gasket Cut and trim armor. Connect each cable cores to the terminal board, referring to the interconnection diagram on next page. 15 14 13 12 11 10 98 76 5 4 3 21 RG12/UY RG-12/UY TTYCY-4 DPYCY-6 RW-9600 Connect inner conductors. M8 screw for grounding Clamp outer conductor of coaxial cables. Fix wires with cable-tie. 4. INSTALLING OPTIONAL EQUIPMENT Processor unit Junction box Antenna unit Junction box RED[B] GRN[B] WHT BRK GRN RED WHT[B] PPL[B] COAX GLY[B] BLU[B] YEL[B] ORG[B] BRN N.C. N.C. N.C. 03P9349 TB802 12 2 13 14 3 4 5 6 7 8 9 10 11 1 TB801 1 2 GND SIG-GND 1 2GND IF_VIDEO RF_SPU_D_B RF_SPU_D_A SPU_RF_D_B SPU_RF_D_A MOTOR(-) MOTOR(-) MOTOR(+) MOTOR(+) 24V_MINUS 24V_PLUS N.C. TX-HV RED[B] GRN[B] WHT BRK GRN RED WHT[B] PPL[B] GLY[B] BLU[B] YEL[B] ORG[B] BRN N.C. N.C. N.C. 03P9342 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 J610 GND SIG-GND 10 2 1 2 3 4 5 6 7 8 9 1 2 1 J613 GND IF_VIDEO RF_SPU_D_B RF_SPU_D_A SPU_RF_D_B SPU_RF_D_A MOTOR(-) MOTOR(-) MOTOR(+) MOTOR(+) 24V_MINUS 24V_PLUS N.C. TX-HV1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 11 12 RW-9600 RW-9600 RG-12/UY DPYCY-6 TTYCY-4 J609 COAX DPYCY-6 DPYCY-6 IV-1.25 pair pair Clamp with cable-clamp 4. INSTALLING OPTIONAL EQUIPMENT This page is intentionally left blank. 4-22 5. INPUT/OUTPUT DATA Input and output data are shown in the table below. Note: This radar accepts position data fixed by WGS-84 geodetic datum only. Set the datum to WGS-84 on the EPFS (GPS, etc.) connected to this radar. If other type of datum is input, the error message "DATUM" appears and the AIS feature is inoperative. Baud rate for the serial input is automatically set to 4800, 9600, 19200 or 38400 as appropriate. Input Data Specifications Contents Remarks Heading signal synchro or step GC-10 required AD-10 and IEC 61162 are switched by menu setting.AD-10 format External AD-100 IEC 61162-2** Speed signal IEC 61162-1 Navaid data IEC 61162-1 Position, course, speed, waypoint, route, time, wind data, current data, depth, temperature, roll, pitch For IMO spec, IEC-61162-1 Edition 2 is required. External radar signal Heading, Bearing, Trigger, Video No STC control Operate as remote display Alarm ACK input Contact closure Input from alarm system IEC61162-1 ACK Input from alarm system Track Control unit RS-422 Option Output Radar system data RS-232C RSD, OSD, TLL, For PC plotter TT data* IEC 61162-1 TTD, TTM, TLB For ECDIS ALARM data IEC 61162-1 ALR For ALARM system Remote display signal HD, BP Trigger, Video 2 ports External LCD monitor signal DVI Same as main display unit 2 systems in total External CRT monitor signal R, G, B, H, V Same as main display unit Option Alarm signal Contact closure Output to alarm system by using photo-relay 4 systems, Output contents are selected by menu. *The output sentence, mode and baud rate can be set at the TT Preset menu. **Data cycle should be input with more than 40 Hz (HSC) or 20 Hz (normal speed). 5. INPUT/OUTPUT DATA IEC 61162 input sentence and priority Contents Sentence and priority Speed (STW) VBW>VHW Speed (SOG) VBW Speed (position) VTG>RMC Heading (True) THS*>HDT* Position GNS>GGA>RMC>GLL Datum DTM Waypoint BWR, BWC, RMB Route WPL, RTE Date, Time ZDA Depth DPT >DBT>DBS>DBK Temperature MTW Wind MWV>VWT>VWR Set and Drift VDR ALARM ACK ACK *: THS and HDT are IEC61162-2 Others: IEC61162-1 ed2. IEC 61162 output sentence Contents Sentence Target L/L Radar system data Own ship data TT target data ALARM data TLL * RSD OSD TTD, TLB, TTM ALR *non IMO-type only. ................ ............................ ........ .................... ........ .............. ........ .......... .... ........ .......... .............. ...... ........ ............ ........................ ...... ...... ............................................ .......... ...................... .......... .......................... .................. .. ............................ .... ................ ............ ...................................... ........................ .. ............................ .... ................ .............. ...................... .................. .. ............................ .... ................ .............. ............................ .................................................................................................................. .................................................. ...................... ........................................................................................................................ ................................................................................................................................................................................................................................ ........................................ A-2 ................ ............................ ........ .................... ........ .............. ........ .......... .... ........ .......... .............. ...... ........ ............ .....

Эта инструкция также подходит к моделям:
Лодочное оборудование - 2127 (5.81 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории