Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации GE, модель PROFILE DPGT650

Производитель: GE
Размер: 2.03 mb
Название файла:
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


Open Gas Valve ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS WARNING – To reduce the risk of fire, electrical shock and personal injury: • Do not use an extension cord or an adapter plug with this appliance. • The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70. ELECTRICAL REQUIREMENTS FOR GAS DRYERS This appliance must be supplied with 120V, 60Hz, and connected to a properly grounded branch circuit, protected by a 15- or 20-amp circuit breaker or time-delay fuse. If electrical supply provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet. WARNING – This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding terminal from this plug. Ensure proper ground exists before use. If local codes permit, an external ground wire (not provided), which meets local codes, may be added by attaching to the green ground screw on the rear of the dryer, and to an alternate established ground. Ground Screw 20 Installation Instructions CONNECTING AN ELECTRIC DRYER (skip for gas dryers) TOOLS AND MATERIALS YOU WILL NEED FOR CONNECTING THE ELECTRICAL SUPPLY . Flat- or straight-blade screwdriver (may be needed for cord strain relief) . #2 Phillips-head screwdriver (for terminal connections) . UL-listed strain relief (may be supplied with cord) . UL-listed power cord – 30-amp – 240V – #10 AWG minimum copper conductor – Closed-loop or forked terminals with upturned ends – 3-wire (for construction before 1996) or 4-wire (for construction after 1996) FOR YOUR SAFETY: WARNING Before making the electrical connection, turn off the circuit breaker(s) or remove the dryer’s circuit fuse(s) at the electrical box. Be sure the dryer cord is unplugged from the wall. NEVER LEAVE THE ACCESS COVER OFF THE TERMINAL BLOCK. ELECTRICAL CONNECTION INFORMATION FOR ELECTRIC DRYERS WARNING – To reduce the risk of fire, electrical shock and personal injury: • Do not use an extension cord or an adapter plug with this appliance. • The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70. 21 Installation Instructions CONNECTING AN ELECTRIC DRYER (cont.) ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS This dryer must be connected to an individual branch circuit, protected by the required time-delay fuses or circuit breakers. A three- or four-wire, single phase, 120/240V or 120/208V, 60Hz, 30-amp circuit is required. If the electric supply does not meet the above specifications, then call a licensed electrician. GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal, permanent wiring system, or an equipment- grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance. CONNECTING DRYER POWER CORD NOTE: Since January 1, 1996, the National Electrical Code requires that new constructions utilize a 4-wire connection to an electric dryer. A 4-wire cord must also be used where local codes do not permit grounding through the neutral. 3-wire connection is NOT for use on new construction. A Remove the terminal block access cover located at the upper back. For 3-wire and 4-wire Connection: Install a UL-listed strain relief into the power cord entry hole beneath the terminal block. Thread a UL-listed 30A, 240V, 3-wire or 4-wire, #10 AWG minimum copper conductor power cord through the strain relief. B For 3-wire and 4-wire Connection: Connect the two hot lines to the outer screws of the terminal block. C CONNECTING DRYER POWER CORD (cont.) WARNING: Do not make a sharp bend or crimp wiring/conductor at connections. Strain Relief (3-wire Connection Shown) (3-wire Connection Shown) Connect outer screws 22 Installation Instructions 23 For 3-wire Connection ONLY: Be sure the dryer’s green ground wire is connected to green ground screw on cabinet rear. D For 4-wire Connection ONLY: Remove the dryer’s ground wire from behind the green ground screw and connect it to the center screw of the terminal block. Attach ground wire of power cord to the cabinet with the green ground screw. CONNECTING DRYER POWER CORD (cont.) For 3-wire and 4-wire Connection: Connect the neutral (center line on 3-wire, white line on 4-wire) line to the center of terminal block. E For 3-wire and 4-wire Connection: Tighten all terminal block screws completely. CONNECTING DRYER POWER CORD (cont.) For 3-wire and 4-wire Connection: Reinstall the terminal block access cover. IMPORTANT: Do not leave the access cover off. F G Ground Wire (3-wire Connection Shown) (4-wire Connection Shown) (3-wire Connection Shown) (3-wire Connection Shown) (3-wire Connectio...

Эта инструкция также подходит к моделям:
Лодочное оборудование - PROFILE UPGT650 (2.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории