|
Фрагмент инструкции
Refer to Table 2 for proper wire size for connection of the input power lines. NOTE: As per the wiring scheme, the ORANGE wire is connected to the positive terminal and the BLUE wire is connected to the negative terminal of the power source. CAUTION: HID light systems, when first turned on, have a high inrush current requirement of 25 amps. If you activate the light and the lamps flicker on and off repeatedly, check the voltage being supplied. This condition can be experienced with voltage input of less than 11.5V. Functions of the URC-300 The URC-300 Master Controller is designed to perform up to six different duties on searchlights, winches and other electrical devices. The Master Controller provides optimum voltage to ensure brightest performance and long lamp life, regardless of boat system voltage fluctuations. The Master Controller is compatible with devices requiring 12 VDC through 24 VDC operation. The URC-300 Master Controller has a searchlight motor time-out feature. If a Point Pad™ rotation switch (right or left) is continually engaged for more than 50 seconds, the Master Controller will interrupt the operation until the Point Pad switch is disengaged. This feature will save the searchlight motor from burnout due to accidental activation. The elevation motor has similar features which will timeout in approximately 20 seconds. XRCiZ™ feature The URC-300 Master Controller has the unique XRCiZ™ feature. The XRCiZ™ feature routinely operates all moving parts of the searchlight to keep the motors and drive mechanism freely running. Once activated, and every 30 days thereafter, the XRCiZ™ feature wakes up and operates the searchlight. The searchlight will rotate 360° in both directions and the parabolic reflectors will move to the full up and down positions. This feature keeps the searchlight in peak working order when not in service for long periods of time. To activate the XRCiZ™ feature, press and hold the Point Pad™ ON/OFF button for greater than 5 seconds. The green LED on the URP- 102 Point Pad™ indicates that the XRCiZ™ feature is enabled. While the XRCiZ™ feature is operating the searchlight, pressing any Point Pad™ button will stop the XRCiZ™ command. To deactivate the XRCiZ™ feature, press and hold the Point Pad ON/OFF button for greater than 5 seconds. The red LED on the URP- 102 Point Pad™ indicates that the XRCiZ™ feature is disabled. NOTE: The Searchlight should not be covered while the XRCiZ™ feature is enabled. Self- Park feature The URC-300 Master Controller has a Self- Park feature. When the Self-Park feature is activated, it will automatically return the searchlight to the forward (or aft, if mounted as such) position when the searchlight lamps are turned off. The feature also works with the XRCiZ™ function to return the searchlight to it Self-Park position. SECTION 6 - POINT PAD™ OPERATION . Press the On/OFF button to turn the lights ON or OFF. . Press the SPEED button to toggle between High and low rotation speeds. . Press the Right or Left arrows to rotate the searchlight in the direction. . Press the Up or Down arrows to raise or lower the searchlight beam. . To activate the XRCiZ™ feature, press and hold the ON/OFF button for more than 5 seconds. The green LED ind9cates that the XRCiZ™ feature is enabled. . To deactivate the XRCiZ™ feature, press and hold the ON/OFF button for more than 5 seconds. The red LED ind9cates that the XRCiZ™ feature is disabled. . An LED blinking red/green indicates that then XRCiZ™ feature is now “exercising” the searchlight. . To activate the Self-Park feature, press and hold the Point Pad™ Speed button for more than 5 seconds. . While the Self-Park feature is operating the searchlight, pressing any Point Pad™ button will stop the park command and leave the searchlight to follow any additional commands. . To deactivate the Self-Park feature, press and hold the Point Pad™ Speed button for more than 5 seconds. . An LED blinking re/green indicates that the searchlight is seeking its Self-Park position. . The Self-Park and XRCiZ™ features are normally disabled when power is lost to the URC-300 Master Controller and will have to be reactivated. NOTE: Self-Park and the XRCiZ™ features are only available when paired with a URC-300 Master Controller. Figure 6 APPENDIX A - SPECIFICATIONS Characteristics Specification Size 12 X 13 X 9.3 in (31 X 33 X 23.5 cm) Weight 31 lb (14.06 kg) Material Cast aluminum, tempered glass Input voltage* 12V- 24V Amp draw Startup 25A @ 12V, Running 8A @ 12V Color White Operation Remote controlled Point Pad™ Beam spread 6° Elevation angle 12° up, 38° down Rotation 360° continuous Rotation speed Fast 30° per second, Slow 12° per second Elevation speed 7° per second Lamp - Twin 35W metal halide lamps - 1,000 hours operating life Accessories - Secondary Point Pad for remote control with Install Kit (ACR P/N 9282.3) - Replacement 35W halide lamp (ACR P/N 6009) Footprint diameter 9 in (23 cm) Limited warranty 1 year Carton dimensions ...
Эта инструкция также подходит к моделям:Лодочное оборудование - 1933 (589.83 kb)