Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Kenwood, модель TH-47E

Производитель: Kenwood
Размер: 8.44 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Paging Code Memories There are 1 1 paging code memories. Use A Store your station ID code in memory. 0 Automatically stores the calling station's code during reception. Can temporarily set the code for the station to be called. 1-9 Stores group codes and local station codes in memory. 4-9-2. Setting the Paging Codes 1. Press the F key, then press the DTSS/PAG key. The P indicator will light. (PAGING MODE) 2. Press the ENT key to enter the CODE SETTING MODE. 3. Select memories (A, 0 to 9) using the tuning control. 4. Enter the code (000 to 999) using the numeric keys. 5. Press the ENT key again to exit the code setting mode. 36 Code setting indicator PAG DTSS coo Frequency ICOCXDCO 000-999 End of code setting] IQED For example, the following groups communicate with each other. Predetermined frequency 145.660MHz Group code 789 Member 1 Individual Code 111 Member 2 Individual Code 222 Member 3 Individual Code 333 Member 4 Individual Code 444 Member 1 A 111 0 1 2 3 789 4 444 ★ 5 6 7 8 9 Member 2 A 222 2 789 0 Member 4 A 444 4 789 0 Member 3 A 333 3 789 0 4-9-3. Paging Transmission (Calling) Your station ID code is preset in memory A. (The local station ID code is always stored in memory A.) 1. Tune to the predetermined frequency. 2. Press the F key, then press the DTSS/PAG key to enter the PAGING MODE. The paging function of the other transceiver must be ON, too. 3. Press the ENT key to enterthe CODE SETTING MODE. 4. Use the tuning control to select the memory channel in which the local station code is stored. PAG DTSS COD Tuning control -tO 00 J' I LI J 0 APO 37 Calling all members of the group. To call all members of the group, select the memory channel in which the group code is stored. In this example, the group code is stored in number 3. Press the PTT switch. Communication is possible in both THE PAGING MODE and THE CODE SETTING MODE. In the paging mode In the code setting mode SSI -, 0 00 :!• 1Q J 0 APO Group code 789 and your station ID code 1 1 1 are transmitted. After the codes are successfully transmitted, a DTMF tone sounds. 38 Calling a specific member. To call a specific member (for example, member 4), use the following procedure: Select the memory in which the remote station code is stored (in this example, select memory 4.), or Enter the individual code of the remote station in memory 0. Then press the PTT switch. Enter the individual code to 0. Remote station code 444 and local station ID code 1 1 1 are transmitted. After the codes are successfully transmitted, a DTMF tone sounds. 4-9-4. Paging Reception (Wait) 1. Tune to the predetermined frequency. 2. Press the F key, then press the DTSS/PAG key to enter THE PAGING MODE. Waiting with individual code. 3. When called with your station ID code, the memory number automatically change to 0. The ID code of the calling station is displayed. (For KENWOOD'S transceivers. This also applies to the following descriptions.) (Example: Frequency: 145.660 MHz, calling station code: 444) P indicates the paging mode. P flashes. m\ Zero is displayed to indicate that the station is being called. 4. The squelch is opened and the calling other party is heard. (The individual code of the calling station is stored in memory 0.) 5. Press the PTT switch to respond to the calling station. After the local station has been called, cancel paging. Communication can be performed more efficiently. ($&: If the remote station code can not be recognized, E appears on the display panel.) These codes are the previous ones. 39 Waiting with group code. 3. When you are called with the group code, the common group code and its memory channel number are displayed. (Example: For member 2, group code 789 is stored in memory for CH 2.) P indicator flashes Group code This code becomes a number other than 0 to indicate group calling. 4. When the PTT switch is pressed, group code 789 (as displayed) and your station ID code are transmitted. You can participate in the group roundtable. After the remote station has been called, cancel paging. Communication can be performed more efficiently. 40 4-9-5. Code Lockout (A code is locked out only during reception with the paging function.) If an individual code is stored in each of memories 1 to 9, reception is enabled when the codes match, even if one remote station communicates with another. To use memories 1 to 9 for transmission only, lock out the memories. When the local station is communicating with two or more groups having the same frequency, lock out the group code with which stand by is temporarily stopped. (Group calling is possible.) • Paging Memory Lockout 1. Enter THE CODE SETTING MODE and display the memory channel number (except memory 0) to be locked out using the tuning control. 2. Press the M key. The ★ mark lights and the memory is locked out. 3. To cancel, repeat steps 1 and 2. 4-10. TONE ALERT SYSTEM The Tone Alert fun...

Эта инструкция также подходит к моделям:
Лодочное оборудование - TH-27A (8.44 mb)
Лодочное оборудование - TH-27E (8.44 mb)
Лодочное оборудование - TH-47A (8.44 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории