Войти:
Оценок - 4, средний балл: 5 ( )

Инструкция по эксплуатации Omega, модель DP18-RT1

Производитель: Omega
Размер: 43.29 kb
Название файла: M2107.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


An OMEGA Te c h n o lo g ie s Co m p a n y DP18 Series Model DP18-RT1 True RMS Ammeter .................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... M2107/1294 INSTRUCTION SHEET True RMS Ammeter for current transformer X/5 3 .DIGITS AC AMMETER, TRUE-RMS VALUES, WITH SELECTABLE RANGES ON THE SIGNAL CONDITIONER BY PLUG-IN JUMPERS. THE READING CAN NOT BE MODIFIED IN ENGINEERING UNITS, UNLESS THE AMPLIFIER IS MODIFIED. THEREFORE USING THE STANDARD AMPLIFIER THE DISPLAY WILL SHOW THE VALUES INDICATED ON THE TABLE. THE INPUT ALLOWS DIRECT CONNECTION TO A CURRENT TRANSFORMER (CT) WITH A 5 Aac. SECONDARY, WITHOUT NEED FOR AN INTERMEDIATE STEP DOWN. FRONT VIEW FIG. 1 SPECIFICATIONS DISPLAYS. . . . . . . . . . . . . . . . . . . . . . HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . SYMBOLS. . . . . . . . . . . . . . . . . . . . . . DECIMAL POINTS . . . . . . . . . . . . . . . . OVERRANGE INDICATION . . . . . . . . . INPUT CONFIGURATION . . . . . . . . . . . ZERO . . . . . . . . . . . . . . . . . . . . . . . . . SPAN ADJUSTMENT. . . . . . . . . . . . . . CONVERTER. . . . . . . . . . . . . . . . . . . . SIGNAL INTEGRATION PERIOD . . . . . READ RATE . . . . . . . . . . . . . . . . . . . . RANGES . . . . . . . . . . . . . . . . . . . . . . . HOLD . . . . . . . . . . . . . . . . . . . . . . . . . NOISE REJECTION NMR . . . . . . . . . . . ACCURACY . . . . . . . . . . . . . . . . . . . . WARMUP TO RATED ACCURACY . . . SPAN TEMPCO . . . . . . . . . . . . . . . . . . ZEROTEMPCO . . . . . . . . . . . . . . . . . . OPERATING TEMPERATURE . . . . . . . STORAGE TEMPERATURE . . . . . . . . . WEIGHT. . . . . . . . . . . . . . . . . . . . . . . . CASE MATERIAL . . . . . . . . . . . . . . . . STANDARD POWER. . . . . . . . . . . . . . POWER CONSUMPTION . . . . . . . . . . . ELECTRICAL CONNECTIONS . . . . . . . BURN-IN . . . . . . . . . . . . . . . . . . . . . . . 3 . digits, 7 segment, red LED 0.56" (14.2 mm.) 1.8.8.8 Selectable by jumpers Display flashes 1999 Bipolar single Automatic ±5% Dual-slope, average value 80 ms. 3.12 / sec. See table selection fig. 3 Optional 50 dB. 50/60 Hz. 0.2 % ± 1 count 2 minutes 150 ppm. 2.5 .V/°C. 0 to 50 °C (32 to 122 °F) -40 to 80 °C (-40 to 176 °F) 310 gr. (0.68 lb) ABS, DIN 43700, black color 115 Vac. ± 10 %, 50/60 Hz. 5.5 VA for AC. Push-in cable connectors 24 h. SPAN OFFSET SPAN :ADJUST THE MAXIMUM READING. OFFSET : NOT IN SERVICE SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR. REAR VIEW FIG. 2 Setpoint R2 Setpoint R1 (option) (option) 110 D C B A + - SIGNAL INPUT Isolated digital output (option) HOLD, latch the reading display, while these pins are linked ANALOG OUTPUT (OPTION) POWER SUPPLY see instrument label RANGE SELECTION FIG. 3 BDF SIGNAL INPUT 5 Aac. PLACE THE PLUG-IN JUMPER ON THE SELECTOR S1, IN FUNCTION OF THE NOMINAL CURRENT TRANSFORMER, AND THE DECIMAL POINT JUMPER ON CORRESPONDING POSITION (FIG. 5). TO OBTAIN THE INDICATED PERFORMANCE, USE CURRENT TRANSFORMERS CLASS 0.5 OR BETTER AC EG A 0.01 0.1 S1 SELECTOR 150 150.0 B 400 400 G 500 500 F 600 600 E 750 750 D 1000 1000 C 1500 1500 B 2000 1999 A CLOSE RESOLUTIONREADINGI NOMINAL Amp.AC Amp.AC JUMPER Amp.ACAmp.AC Amp.AC 5 5.00 F 10 10.00 C 15 15.0 B 40 40.0 G 50 50.0 F 60 60.0 E 75 75.0 D 100 100.0 C JUMPER Amp.AC I NOMINAL READING CLOSE RESOLUTION B C SIGNAL CONDITIONER COMPONENTS VIEW IC2 0.1 1 THE CCD1294APC2BA DP18 Series ............................................................ OPTIONS AND POWER SUPPLIES AVAILABLE FOR DP18 Series CONTROL OUTPUT/COMMUNICATIONS OPTIONS Select a maximum of one option from each column POWER SUPPLY OPTIONS OPTION DESCRIPTION OPTION DESCRIPTION BCD PARALLEL BCD, OPTOISOLATED A01 ANALOG OUTPUT, mA SINK R1 SINGLE SETPOINT, 3 Amp. Relay A02 ANALOG OUTPUT, mA SOURCE R2 DUAL SETPOINT, 3 Amp: Relays A03 ANALOG OUTPUT, VOLTAGE APH1 ANALOG PEAK HOLD APH2 ANALOG PEAK HOLD 232 ISOLATED SERIAL OUTPUT RS-232 OPTION POWER OPTION POWER 230 230 Vac 50/60 Hz STD 115 Vac 50/60 Hz 15/30 Vdc 15...30 Vdc. -10% (3.5 W) isolated 24 24 Vac 50/60 Hz 24/65 Vdc 24...65 Vdc (4 W) isolated 48 48 Vac 50/60 Hz SELECTION OF : DECIMAL POINTS AND SPECIAL OPTIONS CONNECTOR FOR ANALOG OUTPUT FIG. 4 AL J1 J2 MOTHER BOARD SOLDER SIDE JUMPERS SELECTION FOR SPECIAL OPTIONS AL:OPEN ONLY WHEN ALARM SETPOINT CARD OPTION IS ADDED .................... DECIMAL POINTS SELECTOR SIGNAL CONDITIONER (solder side) MOTHER BOARD COMPONENTS SIDE POWER SUPPLY CONNECTOR FIG. 5 (OPTIONAL) INSTALL THE JUMPER IN J1: OPEN TO ELIMINATE THE LEAST-SIGNIFICANT DIGIT(LSD) THE INDICATED PLACE, J2: OPEN TO ELIMI...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории