Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Omega, модель DPG5500

Производитель: Omega
Размер: 652.26 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Turn gauge off when not in use to conserve battery life. Basic Configuration Engineering Unit Selection Engineering unit selection is done via internal buttons to help prevent accidental or unauthorized changes. The selected engineering unit is stored in non-volatile memory and will be retained even with the gauge off or batteries removed. The available engineering units depend on the sensor range and available display resolution. Compound (inHg/PSIG) gauges must be changed to display single- unit vacuum/pressure readings in the Advanced Configuration mode before different engineering units can be selected. The default engineering units are mathematically converted to the newly selected engineering unit. When the gauge is powered up, the originally configured range is displayed and then the conversion with the selected engineering unit is displayed. To change engineering units remove the rear cover to gain access to the two internal buttons located near the lower right and left corners of the circuit board. With the gauge powered up, press and hold the UP button. Release the button when the engineering units begin to flash. Use the UP and DOWN buttons to scroll through the list of engineering units available for the pressure range of the sensor. When the desired units are displayed, press and release the front button to save the selection and return to normal operation. Note: The gauge will automatically revert to normal operation if no buttons are operated for approximately 15 seconds. Replace the rear cover taking care not to pinch the power wires between the cover and the case. Auto Shutoff Time Selection Auto shutoff time selection is done via internal buttons to help prevent accidental or unauthorized changes. The selected shut off time is stored in non-volatile memory and will be retained even with the battery off or batteries removed. Remove the rear cover to gain access to the two internal buttons located near the lower right and left corners of the circuit board. With the gauge powered up, press and hold the DOWN button. Release the button when the auto shutoff time is displayed. The lower display will indicate AST M if the time displayed is in minutes, and AST H if it in hours. An auto shutoff time of 0 signifies that the auto shutoff feature is disabled and the front button turns the gauge on and off. Use the UP and DOWN buttons to select 0, 1, 2, 5, 10, 15, 20 or 30 minutes, or 1, 2, 4, or 8 hours. When the desired time is displayed, press and release the front button to save the selection and return to normal operation. Note: The gauge will automatically revert to normal operation if no buttons are operated for approximately 15 seconds. Replace the rear cover taking care not to pinch the power wires between the cover and the case. Advanced Configuration Advanced configuration requires a pass code for access and allows more features to be configured. Remove the rear cover to gain access to the buttons located near the lower right and left corners of the circuit board. With the gauge off, press and hold the UP button. Then press the front button. Release all buttons when the display indicates CFG and the program version then the full-scale range is indicated and the display is tested. The display then indicates _ _ _ _ with the first underscore blinking, and with CFGPC (configuration pass code) on the character segments. Note: The gauge will automatically revert to normal operation if no buttons are operated for approximately 15 seconds. To cancel and return to normal operation, press and release the front button without entering any pass code characters. Pass Code Entry The factory default is 3510, but this may be changed by the user under the Pass Code Configuration section. 1. Use the UP or DOWN buttons to set the left-most digit to 3. 2. Press and release the front button to move to the next position. The 3 will remain, and the second position will be blinking. 3. Use the UP or DOWN buttons to select 5. 4. Press and release the front button to index to the next position. 35 will remain, and the third position will be blinking. 5. Use the UP or DOWN buttons to select 1. 6. Press and release the front button to index to the next position. 351 will remain, and the fourth position will be blinking. 7. Use the UP or DOWN buttons to select 0. 8. Press and release the front button to proceed with configuration procedures. If an incorrect pass code is entered, the gauge will return to the start of the pass code entry sequence. Factory/User Configuration The upper display section will be blank, and the lower section will display either USER_ or FCTRY. If USER_ is selected, the user configuration can be modified as described in the following steps. To select USER_, press and release the DOWN button. The lower display will indicate USER_. Press and release the front button to continue. If FCTRY is selected, the existing user configuration will be replaced by the original factory configuration. To select...

Эта инструкция также подходит к моделям:
Лодочное оборудование - DPG3500 (652.26 kb)
Лодочное оборудование - DPG5600 (652.26 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории