Flashing GREEN Constant Beeping (every 1/2 second) Low Battery Warning - The Back-UPS is supplying battery power to the load connected to the battery outlets, and the battery has 1.5 minutes of battery power remaining. Alternating GREEN & RED Constant tone Bad Battery Detected - Battery needs to be charged, or is at end of life and must be replaced (see Replace Battery). FlashingRED Constant tone Battery Disconnected - The battery is disconnected or it is a bad battery (see Replace Battery). Off Short beep every 4 seconds Low Battery Shutdown - During On Battery operation the battery power was almost completely exhausted, and the Back-UPS is waiting for utility power to return to normal. Off Constant Tone On Battery Overload - Connected equipment requires more powerthan provided by Back-UPS battery. Unplug devices one at a time to remove overload. If not corrected contact APC Technical Support. GREEN On Constant Tone On Line Overload - The power drawn by the connected equipment exceeds the power capacity of the Battery Backup. FlashingRED Chirp every 2 seconds Charger Warning - Back-UPS has experienced an internal problem, but continues to power the load. Contact APC Technical Support. Off Constant Tone Charger Fault - Back-UPS has an internal problem, and is no longer powering the load. Contact APC Technical Support. AlternatingGREEN/AMBER/RED Off Button Program Mode - see Section 4, and the table below. GREEN Flashing Off Low Sensitivity Mode - see Section 4, and the table below. RED Flashing Off Medium Sensitivity Mode - see Section 4, and the table below. AMBER Flashing Off High Sensitivity Mode - see Section 4, and the table below. Status Indicators 4 Transfer Voltage and Sensitivity Adjustment (Optional) In situations where the Back-UPS, or connected equipment, appears too sensitive to the input voltage, it may be necessary to adjust the transfer voltage. This is a very simple task that requires the use of an ON/OFF push button. To adjust the transfer voltage, perform the following steps: 1. Plug the Back-UPS into the utility power source. The Back-UPS will be in “Standby mode” (no indicators are lit). 2. Press the ON/OFF push button fully in for 10 seconds. The Online LED will begin glowing in a cyclical order: GREEN-AMBER-RED, indicating it is going into “Program mode”. 3. The Back-UPS will then indicate the current sensitivity, as shown in the Transfer Voltage and Sensitivity Adjustment table below. 4. To select the LOW sensitivity setting, press the ON/OFF push button until the LED begins flashing GREEN. 5. To select the MEDIUM sensitivity setting, press the ON/OFF push button until the LED begins flashing RED. 6. To select the HIGH sensitivity setting, press the ON/OFF push button until the LED begins flashing AMBER. 7. To exit Programming mode, once sensitivity is set, wait approximately 5 seconds, and all of the LED indicators will be off (unlit). Connect Equipment Transfer Voltage and Sensitivity Adjustment Indicators Flashing Sensi...
Эта инструкция также подходит к моделям:Лобзики и пилы - BACK-UPS BR650CI (309.8 kb)
Лобзики и пилы - BACK-UPS BR650CI (309.8 kb)
Лобзики и пилы - BACK-UPS BR650CI-AS (309.8 kb)
Лобзики и пилы - BACK-UPS BR650CI-AS (309.8 kb)