Войти:
Оценок - 5, средний балл: 3.6 ( )

Инструкция по эксплуатации Casio, модель PA-2500

Производитель: Casio
Размер: 70.71 kb
Название файла: pa-2400_flce.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


All rights reserved. Chapter 1. Chapter 2. 2.1 2.1.1 2.1.2 2.1.3 2.2 2.3 2.4 2.5 Chapter 3. 3.1 3.1.1 3.1.2 3.2 3.2.1 3.2.2 Table of Contents Overview 3 Installation 4 Installation of PC 4 Connection 4 Start Up 4 Environment Setup 5 Direct Connection of H/PC to Host PC 6 Connection of H/PC to Host PC via I/O Box 6 Installation of Satellite I/O Box (1 unit) 7 Installation of Satellite I/O Box (multiple units) 8 File Transmission/Reception 9 File Upload 9 Specifying File from PC Side 9 Specifying File from H/PC Side 11 File Download 13 Specifying File from PC Side 13 Specifying File from H/PC Side 15 2 1. Overview This manual describes the connection method for implementing file transfers between a Host PC (Windows-version Upload/Download Utility) and PA-2400/PA-2500 (hereinafter referred to as H/PC). Only the PA-2400 can be connected via a Satellite I/O Box. Fig. 1.1 Example of Connection via Satellite I/O Box PC HOST Satellite I/O Box PA-2400 RS-232C IrDA Satellite I/O Box Satellite I/O Box RS-422 PA-2400 PA-2400 IrDA IrDA RS-422 Fig. 1.2 Example of Direct Connection of H/PC to Host PC RS-232C cable: TPX1375-010100 (Part no. 33356594) PC HOST PA-2400/ PA-2500 RS-232C 3 2. Installation 2.1 Installation of PC 2.1.1 Connection Plug the connection cable into the COM1 connector of the Host PC. Note: There are two types of connection cables: one is for direct connection to an H/PC, and the other is for connection via the I/O Box. 2.1.2 Start Up Turn on the power to the PC to boot Windows95, then execute the Upload/Download Utility. Make sure that the main menu screen of the Upload/Download Utility appears. Fig. 2.1 Upload/Download Utility Main Menu Screen 4 2.1.3 Environment Setup Select "RS-232C" from the Configure menu of the Upload/Download Utility, and then select “Settings”.. Fig. 2.2 Environment Setup Screen Set up appropriate conditions by comparing them to the data described above. Click on the [OK] button if setup has been completed. Note: The maximum baud rate that is achieved in communication may differ from the setting in the "Baud rate" entry field, depending on the state of the PC at that point in time. 5 2.2 Direct Connection of H/PC to Host PC Connection Plug the communication cable into the 16-pin interface of the H/PC to connect the Host PC. Start-up Turn on the power of the H/PC. 2.3 Connection of H/PC to Host PC via I/O Box Connection Mount the H/PC on the I/O Box. Start-up Turn on the power of the H/PC. 6 2.4 Installation of Satellite I/O Box (1 unit) Environment Setup 1) Make sure that the POWER switch of the I/O Box is set to OFF. 2) Set the DIP switches provided on the rear panel to the following. Table 2.1 1 2 3 4 5 6 7 8 9 10 ON OFF OFF OFF ON OFF ON ON ON ON Note: The above settings assume that the communication speed is set to 115,200 bps. To set a different baud rate modify the SW6, SW7, and SW8 settings as follows: Table 2.2 Baud Rate SW6 SW7 SW8 9,600 bps OFF ON OFF 19,200 bps ON ON OFF 38,400 bps OFF OFF ON 57,600 bps ON OFF ON 115,200 bps OFF ON ON Connection 1) Connect the AC adaptor to the I/O Box. 2) Connect the I/O Box to the PC with the RS-232C cross-type cable. Start-up 1) Set the POWER switch to ON. 2) Make sure that the “READY POWER” lamp lights in green. 7 2.5 Installation of Satellite I/O Box (multiple units) Note that the DIP switch settings should be made according to whether the I/O Box is connected directly to the PC or daisy-chained to other I/O Boxes. The following environment setup example assumes a baud rate of 115.2 Kbps has been set. Environment setup 1) Make sure that the POWER switch is set to OFF. 2) Set the DIP switches of the I/O Box to be connected with the PC as follows. Table 2.3 1 2 3 4 5 6 7 8 9 10 ON OFF OFF OFF OFF OFF ON ON ON ON 3) Set the DIP switches of other I/O Boxes as follows. Table 2.4 1 2 3 4 5 6 7 8 9 10 ON OFF ON OFF OFF OFF ON ON ON ON Note: Set No.5 of the DIP switch to ON if the C-OUT terminal is not chained to other I/O Boxes. A terminator should be connected to it. Table 2.5 5 ON Connection 1) Connect an AC adaptor to each I/O Box. 2) Connect the I/O Box to the PC with the RS-232C cross-type cable. 3) Connect the C-OUT terminal of the I/O Box, which is connected to the PC, and the C-IN terminal of the other I/O Box with the RS-422 cable. 4) Chain together the remaining I/O Boxes. The I/O Box attached to the terminator must be at the end of the chain. Start-up 1) Set the POWER switches of all the I/O Boxes to ON. 8 3. File Transmission/Reception 3.1 File Upload Transfers the files on the H/PC to the PC side. 3.1.1 Specifying File from PC Side Setup at Host PC Initiate the Upload/Download Utility on the PC, then select "Command" from the "Execute" menu to invoke the Communication Command screen. Fig. 3.1 Communication Command Screen In the Communication Command screen set up the following communication options: . Set the "Command" field to "Receive". . In the "File" field enter the pathname of a file to be transferred to the H/PC. . I...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории