Войти:
Скачали: 11   Размер: 592 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

IO-354B 5151 Felipe, Suite 500, Houston, TX 77056 04/09 © 2008-2009 Goodman Manufacturing Company, L.P. RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During installation or repair, caution is to be observed. It is your responsibility to install the product safely and to educate the customer on its safe use. C US ® *NOTE: Please contact your distributor

Скачали: 14   Размер: 596 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

ATTENTION INSTALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During installation or repair, caution is to be observed. It is your responsibility to install the product safely and to educate the customer on its safe use. These installation instructions cover the outdoor installation of self contained package air conditioners and heating units. See the Specification Sheets applicable to your model for information

Скачали: 8   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

• When the set temperature is to be changed: Room Temperature Over 27°C (81°F) 20~27°C (68~81°F) Below 20°C (68°F) OperatingMode Cool Dry Heat Set Temp. Monitor 24°C (75°F) 26°C (79°F):18/24K 27°C (81°F):9/12K............ • The room temperature is adjustable as you desire by pressing the room temperature setting. • The adjustable range is up to 4°C (8°F) plus or minus. • Automatic operation will not show the set room temperature. • The room temperature automatically appears in the display indica

Скачали: 3   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

(Take care not to twist or crimp pipes during installation.) For Right Rear Sided, Right Sided and Lower Sided Piping NOTE: Do not apply excessive force to these parts. 1. For right side and lower side piping, cut the indoor unit base(s) with a hacksaw and deburr the cut end with a file. (See Fig. 5) 2. Hang the indoor unit(s) on the upper portion of the installation plate while inserting the vinyl-taped pipes through the wall hole. Engage the lower projection with the claws of the installation

Скачали: 3   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

• Indoor fan motor(s) stop: In the “AUTO”, “DRY” and “HEAT” operation mode, the indoor fan motor(s) will be stopped when the room temperature reaches the set temperature. • The air conditioner(s) do not start or change operation mode immediately: To prevent overloading the compressors, the air conditioner(s) will not start for approx. 3 minutes. • No change on the operation mode by the remote control: The signal of operation mode changing has not reached the indoor unit(s). Press the ON/OFF butt

Скачали: 4   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

• All field piping must be installed by a licensed refrigeration technician and must comply with all national and local codes. • Never plug unit(s) into an electrical outlet. • Do not touch compressor, pipes and valves without protective gloves during and after operation, because these parts may become hot (more than 100°C (212°F). • Explain the operating procedure of the air conditioner to the customer. Outdoor unit mounting leg dimension additional refrigerant amount =0.22oz./ft.>25’. 18/24 Bt

Скачали: 8   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

tion. Then press the ON/OFF button again, the unit will be set to the previous operating mode. • Upon input, one-hour timer is set at display and 0:30 is indicated current time. • If 1hr timer is set, the remaining minutes will be indicated. NOTE: • If pressing the 1HR TIMER button again during the ONE HOUR TIMER mode, the unit will stop operation approximately one (1) hour later. • The ONE HOUR TIMER mode has preference over other Timer modes. If pressing the 1HR TIMER button again during the O

Скачали: 3   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

ECR International Hyundai Ductless Split System6 mark will blink button. OPERATION (Continued) OPERATION CONDITION TIMER MODE (ON, OFF) mark will blink button. OPERATION (Continued) OPERATION CONDITION TIMER MODE (ON, OFF) • The timer can be set during any mode. Select the timer setting by pressing: ON-TIMER button or OFF-TIMER button. (Example) Time is AM 10:20. Air-conditioner is not in operation. How to start the air conditioner at PM 1:30 and stop it at PM 6:30. mark will blink 1. Press the

Скачали: 4   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

B. Remove burrs from cut edges of pipes, which may cause a gas leak. C. Flaring of the pipe is done with the flaring tool. NOTE: Do not forget to install the flare nut before flaring 2. Pre-Connecting: Screw the tubing turning 3 to 5 times until hand tight. 3. Fastening: Fasten the connection. • Apply refrigeration oil to the flare surface to pre- vent gas leakage. Air Purge and Charging! CAUTION ! 1) Remove the cap from the service port on the suction line service valve. 2) Connect the suction

Скачали: 6   Размер: 947 kb   Производитель: Goodman Mfg  
Категория: Кондиционеры
@name

Up/Down Air Flow Direction Control OPENCLOSED Operation starts by manipulating the Remote Control. Please check and identify the name and location of part. ACL Button (Front Cover) Cover1 2 PART NAME OF REMOTE CONTROL AND KEY FUNCTION PREPARATION BEFORE OPERATION Transmitter Low Battery Indicator Display Window ON/OFF Button Temperature Setting Button High Power Button One Hour Timer Button ON-Timer/OFF-Timer Selector Buttons ACL Button Timer Setting/Temperature Setting Operation Mode Selector B





Категории