Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Haier, модель 0010571564

Производитель: Haier
Размер: 160.51 kb
Название файла: 6b7c9b9e-691f-4daa-a2b7-9d31d3de86c1.pdf

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


2.Free choice of wire control and remote control. 3.Several types of indoor units, free combination of specification. 4.Single outdoor unit, space-saving and cost-saving. 5.Far distance network technology, realize the intelligentized living area (For details, please refer to the manual of indoor unit). 6. POWER FAILURE RESUME FUNCTION. Automatic set when power resumes. Safety Precautions The following lists four kinds of safety precaution items and suggestions: Warning: Improper use may cause death or serious injury. Notice: Improper use may cause body hurt or unit damage; in some ! ! circumstance, it may cause serious results. : Those contents marked with iProhibitioni are definitely prohibited action, otherwise, it may cause unit damage or risk to usersi safety. : Those contents marked with iForcedi are definitely forced action, otherwise, it may cause unit damage or risk to usersi safety. The following safety precautions must be observed. This safety precautions should keep in hand for reference. Warning ! Commissioned installation Ask after-sales service worker to take The installation work should be done bymeasure to prevent refrigerant fromthe after-sales service worker. Self-leaking. installation may cause water leakage,If the leaked refrigerant exceeds a certainelectric shock and fire accident because of density, it will cause lack of oxygen. Ifimproper installation. the room installed with air conditioner It is strictly prohibited to rebuild the airconditioner by yourself. Improperrebuilding may cause fire, electric shockis too small, do take enough measure inorder to avoid lack of oxygen even ifrefrigerant leaks. and water leakage. When the air conditioner must be If still using the unit underthis circumstance, the air If abnormal conditions (sear smell) occur, please stop the unit, turning off the electricpower and contact the after-sales servicecenter for solution. dismantled and reinstalled, please askthe after-sales service center to do this work. Improper installation may cause waterleakage, electricshock and fire. conditioner may be damagedand may also cause electricshock or fire accidents. Cut off power After a long-time using of the airconditioner, please check if thefoundation of the unit is damaged. When needing repair, please ask the after- sales service work for help. Improper maintenance and repair mayIf the foundation is damaged withoutrepair, the unit may falldown leading to body hurt. cause water leakage, electric shock andfire. During the unit operation, do not insert fingers or otherarticles alike into the air Any inflammable spray liquid cannotbe place or use near the air conditioner, otherwise, fire accident may happen. inlet, outlet and louver. Because the high-speedfan is very dangerous, it may cause hurt. Only after stopping the unit and cuttingoff power can clean the airconditioner to avoid electric shock or injury. 1 Name of Parts 3 3 1 2 4 1 2 4 Air inlet Air outlet Air inlet Repair panel Note: Do not block the air inlet and air outlet, otherwise the performance of the airconditioner may be lowered. 2 Installation procedure Install indoor unit 1.Choose installation place The chosen installation place should meet the following requirements and get the useris consent. Place air can freely circulate. Place can perform level installation. The condensate water can be drained smoothly. Place where the noise and hot air will not >10cm >15cm >60cm >10cm >30cm disturb the neighbors. Place can ensure the space for successful maintenance and repair. Place where the four corners of the unit are easily installed and leaves at least 1m height space. Place where the wall hole is easy for drainage. When installing multiple units, make sure to leave enough space to avoid air short-circuit. If the outdoor unit near the street, it should not be lower than 2.5m. Please install in the place that can sufficiently bear the weight of the unit. The air conditioner cannot install on a non-special metal frame (e.g. theft guard net). Install in the place with intensity as high as possible to prevent the noise and vibration from spreading to other places. Avoid the place where the strong airflow directly toward the air inlet or air outlet. Avoid the place where high frequency electromagnetic waves are generated to prevent the communication of indoor and outdoor from being affected. Avoid the place where the combustible gas exists. The combustible gas around the air conditioner may cause fire. Avoid the place where the combustible gas may be leaked. If the leaked gas gathers around the air conditioner, it may cause fire accident. Avoid the place with to much oil, vapor and salinity, such as, seashore and hotspring area and the area with sulfurated gas, etc. corrosive gas. If install in these places, the air conditioner needs special maintenance. Avoid the place where the heat source directly radiates or with other heat sources. 3 Installation instruction Installation tools 1.Screwdriver 2. Steel saw 3...

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории