Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации GE, модель 7500 SERIES

Производитель: GE
Размер: 837.02 kb
Название файла: vertical_use_care_manual.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . .2 Operating Instructions Controls—Dip Switches . . . . . .3–5 Controls—Terminal Connections . . . . . . . . . . . . . .6, 7 On/Off Switch . . . . . . . . . . . . . . .8 Ventilation Control . . . . . . . . . . .8 Care and Cleaning Air Filters . . . . . . . . . . . . . . . . . . .9 Base Pan . . . . . . . . . . . . . . . . . . .9 Exhaust Coils . . . . . . . . . . . . . . . .9 Installation Instructions Electrical Supply . . . . . . . . .11–13 Installing the Zoneline . . . .14–21 Preparation . . . . . . . . . . . . . . . .10 Servicing . . . . . . . . . . . . . . . . . .22 Troubleshooting Tips . . . . . . .23 Normal Operating Sounds . . . .24 Consumer Support Consumer Support . . .Back Cover Product Registration . . . . . .25, 26 Warranty . . . . . . . . . . . . . . . . . .27 Write the model and serial numbers here: Model # __________________ Serial #____________________ Find these numbers on a label on the front case panel. Owner’s Manual and Installation Instructions Heat/Cool and Heat Pump Models 7500 Series 49-7419-1 11-01 JR Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock, or to prevent property damage, personal injury, or loss of life. n This Zoneline must be properly installed in accordance with the SAFETY PRECAUTIONS Installation Instructions before it is used. See the Installation Instructions in the back of this manual. ¦ Immediately repair or replace all electric service cords that have become frayed or otherwise damaged. ¦ Unplug or disconnect the Zoneline at the fuse box or circuit breaker before making any repairs. NOTE: We strongly recommend that any servicing be performed by a qualified individual. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS 2 Controls–dip switches. GEAppliances.com Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service Controls–Dip Switches The dip switch controls are located behind the front case panel, through an opening on the front of the unit. To access the dip switches, remove the front case panel by removing the filter, taking out the four front screws, the upper two screws from the top of the panel and the shipping screws on each side, if present. (Discard the two side shipping screws, if present). Dip Switches Side shipping screw Side shipping screw The factory settings will be in the DOWN position. NOTE: The owner is responsible for setting the appropriate dip switches and connecting terminals. TL1 (C) (Temp. Limit 1–Cool) TL2 (C) (Temp. Limit 2–Cool) TL3 (C) (Temp. Limit 3–Cool) ALL I2R (All Electric Heat) (Heat-pump models only) FREEZ S (Freeze Sentinel) CONST FAN (Constant ON Fan) TL1 (H) (Temp. Limit 1–Heat) TL2 (H) (Temp. Limit 2–Heat) TL3 (H) (Temp. Limit 3–Heat) No Function (Reserved for future use) DUCT (Blower Fan) OCCUPIED (Occupancy Sensor) All Electric Heat (Heat pump models only) When this switch is enabled (UP), heat pump operation is locked out, causing the unit to provide only electric resistance heat. ALL I2R (All Electric Heat) 3 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RAVRMS) When this switch is enabled (UP), it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN), the freeze sentinel is activated which automatically provides heat without user interface. This helps to prevent plumbing damage by turning the heater and fans ON at 41° F and OFF at 46° F. FREEZE S (Freeze Sentinel) Constant ON Fan When this switch is enabled (UP), it allows the fans to run continuously, at high speed, even if the unit is in the STOP position. CONST FAN (Constant ON Fan) Occupancy Sensor When this switch is enabled (UP), it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection. This feature allows an energy management system to be installed and operated in conjunction with the unit. OCCUPIED (Occupancy Sensor) Duct The duct select function allows the indoor fan to be operated at two variable fan speeds, depending on the duct length. When this switch is enabled (UP), the unit automatically selects either high or middle fan speed for longer ductwork applications. When set in the down position, the unit is automatically operated in DUCT (Blower Fan) either the middle or low fan speed for shorter ductwork applications. 4 GEAppliances.com Temperature Limiting (Requires room air sensor kit–RAVRMS) Temperature limiting can reduce energy costs of auxiliary controls. The first three switches are by limiting the lowest temperature that can be used to select the cooling limits. The next three set for cooling and the highest temperature that switches are used to contro...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории