Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Fedders, модель A6X05F2D

Производитель: Fedders
Размер: 326.4 kb
Название файла: 8d6cb6a1-acde-a474-3db0-f52a42a53f89.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


The Temperature/Hour Display Shows the set temperature or the timer setting. THE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT THE ACTUAL ROOM TEMPERATURE. Temperature/Hour Controls These buttons are used to raise or lower the set temperature in increments of 1° from 66° to 88°. They also raise or lower the hour setting in increments of 1 from 00 to 24 when the timer is being set. In order to toggle between °F or °C, depress both of the controls at the same time. Mode Control The Mode Control has two settings: FAN and COOL. The settings are adjusted with the Mode Control button. A green light indicates which setting is currently being used. When the COOL mode is selected, the unit will circulate and cool the air. If the FAN mode is selected, the unit will only circulate the air. Fan Speed Control The Fan Speed Control has three settings: High, Low and Auto. The settings are adjusted with the Fan Speed button, each time the button is depressed it changes the setting. A green light will indicate which setting is currently being used. When the Auto feature is selected while the air conditioner is in the COOL mode, the fan speeds will change automatically as the temperature in the room changes. • 4° or more above the set temperature the unit will be in HI FAN mode. • 4° or less above the set temperature the unit will be in LO FAN mode. Timer Control The timer can be set to either turn the unit on or off. To turn the unit on using the Timer: •Depress the timer key when the power is off, the display will read 00. Adjust to the desired number of hours before TURN ON using the up/down arrows. •The display will show the time by hours left until TURN ON. •To Turn the timer off, depress the timer key. •A green light next to the Timer Control indicates that the timer is set. To turn the unit OFF using the Timer: •Depress the timer key when the power is on, the display will read 00. Adjust to the desired number of hours before TURN OFF using the up/down arrows. The display will automatically go back to the set temperature after 10 seconds. •To display the amount of time left until TURN OFF, depress the timer button once. •To turn the TIMER OFF, depress the timer button twice. •A green light next to the Timer Control indicates that the timer is set. Built-in three minute timing delay. If this electronic unit will not respond to touch pad or remote control commands, it is necessary to unplug the unit from the electrical outlet for five seconds and then plug the unit back in. Auto restart feature: In the event of a power failure, this feature allows the unit to resume operation once power has been restored, retaining the most recent settings. Upon restoration of power, the timer mode may need to be reset if being utilized. 4 Room Air Conditioner Cleaning the Air Filter Room Air Conditioner Cleaning the Air Filter Air Conditioner Remote Control The functions work the same as your air conditioner’s touch controls. CAUTION • Use only AAA or IEC R03 1.5V batteries. • Remove the batteries if the remote controller is not used for a month or longer. • Do not attempt to recharge the supplied batteries • All batteries should be replaced at the same time. • Do not dispose of the batteries in a fire as they may explode. • Do not mix old and new batteries. • Do not mix alkaline, standard (carbon - zinc), or rechargeable (nickel-cadmium) batteries. • Do not install the batteries with the polarity (+/–) reversed. • Keep batteries and other things that could be swallowed away from young children. Contact a doctor immediately if an object is swallowed. Every two weeks: Clean the Filter 1. Turn power to OFF. 2. Remove the air filter by grasping the top corners and pulling it up and out of the unit (Fig. 8). 3. Wash in hot soapy water, rinse and shake dry. 4. Replace the filter, with the front of the filter toward you. 5. To dry the filter thoroughly, run your unit for a few minutes. Remember, only a clean filter works properly and delivers top efficiency at every setting. Proper use and care of your air conditioner will help ensure longer life of the unit. It is recommended to have the unit inspected annually, as well as having the coils and condensate water passages cleaned. Expense of the annual inspection is the consumers’ responsibility. Air Filter Decorative Front 8 AAAIEC R031.5V+- AAAIEC R031.5V7 Note: Failure to keep air filter clean will result in poor air circulation. DO NOT operate without filter. This can render the unit inoperable. Decorative Front Removal 1. Turn the unit off and remove the plug from the outlet. 2. Remove the screws on either side of the cabinet (Fig. 9). 3. Gently pull forward while grasping both sides of the decorative front. 4. To replace the decorative front, line up the top and bottom and sides, and gently press into position. 5. Reattach the screws on both sides of the decorative front. Make sure the decorative front is secure before reconnecting the plug and operating the unit. Remove screw f...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории