Инструкция по эксплуатации York, модель AFFINITY 291627-YTG-B-0807

Производитель: York
Размер: 1.34 mb
Название файла: fee5a15f-f940-4fbf-a6b0-830bf45fa8b1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If the resistance of the return air duct system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation. NOTE: HEAT ANTICIPATOR SHOULD BE SET AT 0.35 AMPS FOR ALL MODELS. THERMOSTAT UNIT TERMINAL STRIP : Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire. ©- ** R G ©- Y W- C 24 VOLT TRANSFORMER PROGRAMMABLE THERMOSTAT ONLY FIGURE 3 - TYPICAL FIELD CONTROL WIRING DIAGRAM CONTACTOR GROUND LUG L l_. FIELD-SUPPLIED DISCONNECT REFER TO ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT THREE PHASE POWER SUPPLY FIGURE 4 - TYPICAL FIELD POWER WIRING DIAGRAM Unitary Products Group 17 291627-YT G-B-0807 TABLE 14: ELECTRICAL DATA MODEL DNH POWER SUPPLY VOLTAGE LIMITATIONS1 COMPRESSOR COND. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, AMPS2 MAX. HACR BREAKER SIZE, AMPS UNIT POWER FACTOR TRANSFORMER SIZE (VA) MIN. MAX. RLA LRA 030 208/230-3-60 187 253 8.6 55 1.1 2.6 14.5 20 20 .96 75 030 460-3-60 414 504 4.3 27 0.6 1.4 7.4 15 15 .96 75 036 208/230-3-60 187 253 11.4 77 1.1 3.5 18.9 25 25 .96 75 036 460-3-60 414 504 5.7 39 0.6 1.8 9.5 15 15 .96 75 042 208/230-3-60 187 253 13.9 88 1.3 3.5 22.2 30 30 .96 75 042 460-3-60 414 504 6.4 44 0.7 1.8 10.5 15 15 .96 75 048 208/230-3-60 187 253 13.0 93 1.9 4.2 22.4 30 30 .96 75 048 460-3-60 414 504 6.4 46.5 1.0 2.1 11.1 15 15 .96 75 060 208/230-3-60 187 253 19.3 123 1.9 9.4 32.9 45 45 .96 75 060 460-3-60 414 504 10.0 62 1.0 4.7 16.0 20 20 .96 75 1. Utilization range “A” in accordance with ARI Standard 110. 2. Dual element, time delay type. 18 Unitary Products Group 291627-YTG-B-0807 VENT AIR OUTLET HOOD GAS SUPPLY 1-1/4" DIA. HOLE (1/2" NPTI CONNECTION) UNIT CONDENSATE CONNECTION 3/4" NPTI (TRAP RECOMMENDED) HIGH VOLTAGE CONN. 1-3/8" DIA. KNOCKOUT HIGH VOLTAGE CONN. 7/8" DIA. KNOCKOUT GAS SUPPLY 1-1/4" DIA. KNOCKOUT (1/2" NPTI CONNECTION) LOW VOLTAGE CONN. 1-3/8" DIA. KNOCKOUT X 7/8" HOLE BLOWER SERVICE ACCESS COMPARTMENT PANEL CONDENSER COIL ^REFRIGERANT CONNECTIONS COMBUSTION AIR INLET LOUVERS FRONT GAS/ELECTRIC CONTROL SERVICE ACCESS (OVERALL) COMPARTMENT PANEL All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIGURE 5 - UNIT DIMENSIONS - FRONT TABLE 15: UNIT DIMENSIONS FRONT UNIT SIZE DIMENSION “A” “B” 030 - 036 33-1/2 18-1/4 042 - 060 41-1/2 23-1/8 TABLE 16: UNIT MINIMUM CLEARANCES1 2 CLEARANCES FRONT 36” REAR 0” LEFT SIDE (Filter-Access) 24” RIGHT SIDE 12” BELOW UNIT3 0” ABOVE UNIT 4 36” (For Condenser Air Discharge 1. A 1” clearance must be provided between any combustible material and the supply air ductwork. 2. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 3. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 4. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. Unitary Products Group 19 291627-YT G-B-0807 FIGURE 6 - UNIT DIMENSIONS - FRONT & BOTTOM FIGURE 7 - UNIT DIMENSIONS - BACK & BOTTOM 20 Unitary Products Group 291627-YTG-B-0807 TO POWER SUPPY CONTROL WIRING FIGURE 8 - TYPICAL SLAB ON GROUND INSTALLATION MANUAL GAS SHUT-OFF VALVI FIELD SUPPLIED DISCONNECT SWITCH MOUNTED ON UNIT TO GAS SUPPLY LINE CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT SUPPLY AIR m ir.T FIGURE 9 - TYPICAL ROOF CURB INSTALLATION Unitary Products Group 21 291627-YTG-B-0807 ROOF CURB INSTALLATION REAR DUCT ROOF CURB SLAB ON GROUND INSTALLATION FIGURE 10 - TYPICAL DUCT APPLICATIONS TABLE 17: UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING OPERATING CORNER WEIGHTS ECONOMIZER (lbs.) ROOF WEIGHT WEIGHT (location, lbs.) CURB (lbs.) (lbs.) “A” “B” “C” “D” (lbs.) 030 395 390 98 95 96 99 036 400 395 100 96 98 101 8” - 70 14” - 75 042 470 465 131 129 101 103 40 048 475 470 133 130 102 104 060 485 480 136 133 105 107 FIGURE 11 - UNIT CENTER OF GRAVITY 22 Unitary Products Group 291627-YTG-B-0807 FIGURE 12 - ROOF CURB DIMENSIONS 1. 8” Roof curb also available 1 FIGURE 13 - ROOF CURB CROSS SECTION Unitary Products Group 23 291627-YT G-B-0807 FIGURE 14 - TYPICAL WIRING DIAGRAM DNH 030, 036, 042, 048 (208/230-3-60 POWER SUPPLY) 24 Unitary Products Group 291627-YTG-B-0807 FIGURE 15 - TYPICAL WIRING DIAGRAM DNH 030, 036, 042, 048 (460-3-60 POWER SUPPLY) Unitary Products Group 25 291627-YTG-B-0807 FIGURE 16 - TYPICAL WIRING DIAGRAM DNH 060 (208-230-3-60 POWER SUPPLY) 26 Unitary Products Group 291627-YTG-B-0807 FIGURE 17 - TYPICAL WIRING DIAGRAM DNH 060 (460-3-60 POWER SUPPLY) Unitary Products Group 27 291627-YT G-B-0807 TYPICAL WIRING DIAGRAM NOTES (SEE FIGURES 14 THRU 17) 1. All field wiring to be accomplished following city, local 7 and/or national codes in effect at time of ins...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории