Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации York, модель AVY24 THRU 60

Производитель: York
Размер: 246.01 kb
Название файла: 87e406a2-e062-4819-8448-1013632aab5b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


256819-YTG-J-1208 DESCRIPTION The Affinity Air Handler line offers the ultimate in comfort, sound and application flexibility. The Affinity models utilize a whisper quiet variable speed motor that provides humidity control and the lowest operating cost in the industry. The AVY air handler is shipped ready to be installed in all positions, upflow, downflow, horizontal left or right, with minor adjustments. The SVY 48 & 60 models are upflow only models designed into a shorter cabinet, for those special applications where reduced height is required. No special kits are required to install this deluxe product in any position. All JCI Unitary Products air handlers and coils use a TXV to provide our customers with the optimum performance and refrigerant control required for 13 + Seer systems. Air handlers can be ordered with either a R-22 or R-410A TXV factory installed. Air handlers are also available with “Flex-coils” without a factory installed metering device, where for added flexibility, a R-22 or R-410A TXV can be field installed to meet your refrigerant choice. FEATURE Thermal Expansion Valve -Provides the ultimate refrigerant control required for today’s high efficient product. The UPG bolt- on TXV provides easy installation to convert the air handler to the required refrigerant, which is a true bolt-on design that does not require brazing to replace or install. MicroBlueTM Coated Fins - All air handler coils are treated with the MicroBlueTM hydrophilic coating to enhance the removal of condensate during the refrigeration cycle and reduce the possibility of water blow-off. The MicroBlueTM coating also reduces the growth of germ causing microbes for a healthier home environment. Insulated Cabinet - All air handler cabinets are thermally insulated with 1” foil faced insulation (R-4.2) to prevent sweating. For applications in extreme humidity conditions an optional, field installed, external insulating wrap kit is also available. Factory - Sealed to achieve 2% or less leakage rate with or without field installed filter at 1.0” water gauge external static pressure. Durable Finish Inside and Out - Air handler casings are made of pre-painted galvanized steel which provides a better paint to steel bond that resists corrosion and rust creep. All internal coil sheet metal parts are made of G90 galvanized. New 4 HK Heat Kit -Installation friendly, easy service, more robust, unique to new design. ECM Variable Speed Motor - Designed for efficient, quiet operation with added indoor comfort control. With the use of a humidistat, the motor will monitor the humidity in the home and automatically keep the desired humidity level in both winter and summer seasons. The ECM motor utilizes only 24% of the energy used by standard blower motors to reduce your overall heating and cooling costs. ClimaTrak Comfort Settings - Installers can set an operating cycle for the ECM motor that works best in a particular climate. Homeowners benefit from an operating cycle that maximizes their indoor comfort level regardless of whether they live in a dry, temperate, or humid climate. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 2 Johnson Controls Unitary Products 256819-YTG-J-1208 DIMENSIONS 10-3/8” F CIRCUIT BREAKER PANEL BOTTOM INLET DIMENSIONS DRAIN PAN CONNECTIONS FOR HORIZONTAL APPLICATIONS BLOWER COMPARTMENT REFRIGERANT CONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICATIONS 7-11/32” D B A C 1-1/2” E TOP OUTLET DIMENSIONS FILTER ACCESS 18-9/32” J K DIMENSIONS Models Dimensions (Inches) Wiring Knockouts1 Refrigerant Connections A B C Line Size D E F J K Height Width Depth Power Control Liquid Vapor AVY24B**H21 46 17.5 21.5 (w/o cladding) 22.5 (with cladding) 12-3/8 13-29/32 14-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 3/4” AVY36C**H21 52 21 17-1/8 17-13/32 18-3/32 7/8” AVY48D**H21 57 24.5 22-1/8 20-29/32 21-19/32 7/8” SVY48D**N21 52 24.5 17-1/8 20-29/32 21-19/32 7/8” AVY60D**H21 57 24.5 22-1/8 20-29/32 21-19/32 7/8’ SVY60D**N21 52 24.5 17-1/8 20-29/32 21-19/32 7/8” 1. Actual size (Conduit size). ** Thermal expansion device indicators - “2_” indicates R-22 TXV is factory installed, “3X” indicates unit is a “Flex Coil” models with a field installed R-22 or R-410A TXV, and “4_” indicates R-410A TXV is factory installed. Letter indicates TXV size as required, see outdoor unit technical information for proper matches and requirements. 256819-YTG-J-1208 COIL TECHNICAL DATA Models Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Fin Per In. Coil Size Tube Geometry Tube Dia. Fin Type TXV AVY24B3XH21 Cooling / Heat Pump Sweat 3.89 2 14 (2) 16 x 17.5 1 x 0.866 3/8 Enhanced None AVY24B2AH21 2A AVY24B4EH21 4E AVY24B4FH21 4F AVY24B4KH21 4K AVY36C3XH21 Cooling / Heat Pump Sweat 4.86 3 12 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced None AVY36C2AH21 2A AVY36C4EH21 4E AVY36C4FH21 4F AVY36C4GH21 4G AVY36C4HH21 4H AVY36C4KH21 4K AVY36C4MH21 4M AVY48D3XH21 Cooling / Heat Pump Sweat 5.83 3 11 (2) ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории