Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации LG, модель P05LH

Производитель: LG
Размер: 2.84 mb
Название файла:
Язык инструкции:en
Фото и характеристики  LG  P05LH
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


2 1. Press the Start/Stop Button. 2. Select the desired Operation Mode. 3. Press the Plasma Air Purifying Operation ON/OFF Button. 4. Set the fan speed. Owner's Manual 21 22 Floor Standing-Type Air Conditioner Operating Instructions 3 1 1 MODE 2 2 Press the Start/Stop Button. (Operation will start when the button is pressed, and stop when the button is pressed again.) Press the Auto Swing Button and then louvers will swing left and right. Press the Airflow Direction Control Button again to set the Vertical louver at the desired airflow direction. The vertical louver swing left and right. The horizontal louver swing up and down. Press the Start/Stop Button. Set the Fan Speed. . Each time the Button is pressed, the Fan Speed mode is shifted. Press Fan Operation Button. Fan Operation Mode(TA* MODEL) Airflow Direction Procedure Operating Instructions Jet Cool Operation 2 3 1 or or On/Off Press the Start/Stop Button. Press the Jet Cool button to operate the speed cooling mode and the unit will operate in high fan speed on cooling mode. To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in mid fan speed on cooling mode. NOTE: . During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available. . In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again. (Z,H/P Model) (C/O Model) Owner's Manual 23 Operating Instructions Child Lock Operation Procedure 2 3 1 After 3 second, it will shift After 3 seconds, it will shift After pressing the buttons it will shift immediately After 3 seconds, it will shift Press the fan speed button and High temperature setting buttons simultaneously for 3 seconds. The unit will respond with beep. During Child Lock Operation Whenever you press any Button on Display Panel, it will immediately display “ ”, which means Display panel is Locked. . All the Button on the indoor unit Display panel will not work. . But the Button on the remote controller will work. For releasing child lock Operation Press the fan speed button and High temperature setting buttons simultaneously for 3 seconds. The unit will respond with beep, Child Lock Operation will removed. Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. 24 Floor Standing-Type Air Conditioner Maintenance and Service Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. During the season Cleaning of the air filters. Recommended about once every two weeks • To remove the dust adhering to the filters, either use a vacuum cleaner, or wash them in water and dry in the shade. • Re-insert the filter to the original position. Cleaning of the air cleaner. Recommended about once every three months Remove the Air Cleaner. Take hold of the tab and pull slightly forward to remove the air cleaner. Clean. • Dip the air cleaner into the water mixed with detergent, for 20~30 minutes, and dry in the shade. • Re-insert the air cleaner to the original position. Remove the Air Filter. Take hold of the tab and pull slightly forward to remove the filter. Clean. Cleaning of the air conditioner • Don’t wash with water. • Wipe with a soft dry cloth. Never use any of the followings. • Water hotter than 40°C. • Volatile substances. Could cause deformation Could damage the surfaces and/or discoloration. of the air conditioner. When the air conditioner is not going to be used for a long time. At the end of the season At the start of the season CAUTIONCAUTION Operation Tips Operate the air conditioner at the following settings for 2 to 3 hours. • Type of operation : Cooling. • Temperature setting : 30°C. This will dry out the internal mechanisms. Remove the batteries from the Remote Control. Turn off the circuit breaker. Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. Clean the air filters, re-insert, then operate the air conditioner. Be sure that nothing obstructs the air outlet and intake vents. Do not overcool the room. This is not good for your health and wastes electricity. Make sure that the doors and windows are shut tight. Avoid opening doors and windows as much as possible to keep the cool air in the room. Keep blinds or curtains closed. Do not let direct sunshine enter the room when the air conditioner is in operation. Clean the air filter regularly. Blockages in the air filter reduce the airflow and low...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории