Инструкция по эксплуатации Samsung, модель AQ09TSBNEUR

Производитель: Samsung
Размер: 5.03 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


• If you do not use the other drain hose hole, block it with a rubber stopper. Drain hose hole 20mm or more 20mm or more 15~20 mm Extension drain hose Drain hose Extension drain hose Drain hose Foam Insulation Vinyl Tape 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. 8. Using natural drainage method, check the drainage is normal. Shield Drain hose Extension drain hose • The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 37~38 for further details. • Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage. • If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors. • DO NOT WALL UP THE DRAIN HOSE CONNECTION ! Drain hose connection must be easy accessible and serviceable. Changing direction of the drain hose Change the direction only when it is necessary. 1. Detach the rubber cap with the plier. 2. Detach the drain hose by pulling it and turning to the left. 3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan. 4. Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove. 5. Check for leakage on both side of the drain outlet. Screw hole Screw Drain hose Drain pan outlet . Direction of the drained water Pour the water in direction of arrow. Rubber cap • Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part. Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following: 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. • To avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit. Drain hole Drain plug Bottom surface of outdoor unit 2. Connect a drain hose to the drain plug. Drain hole Drain plug Drain hose 3. Ensure that condensation draining is adequate. Snow-proof hood • In areas with heavy snow fall, piled snow could block the air intake. To avoid this incident, install a frame that is higher than estimated snow fall. In addition, install a snow-proof hood to avoid snow from piling on the outdoor unit. Estimated snow fall Frame Ground Purging the connected pipes The outdoor unit is loaded with sufficient R410A refrigerant. Do not vent R410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture. • When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. It may cause explosion and injury. 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. 2. Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque: Outdoor unit Indoor unit Gas pipe side Liquid pipe side • Excessive torque can be cause of gas leakage. Outer Diameter Torque (kgf•cm) o6.35 mm 140~170 o9.52 mm 250~280 o12.70 mm 380~420 o15.88 mm 440~480 o19.05 mm 990~1210 o22.23 mm 990~1210 • Make the electrical connection and leave the system into “stand by mode”. Do not turn on the system! This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -). 3. Connect the char...

Эта инструкция также подходит к моделям:
Кондиционеры - AQ09TSBXEUR (5.03 mb)
Кондиционеры - AQ09UGFN (5.03 mb)
Кондиционеры - AQ09UGFX (5.03 mb)
Кондиционеры - AQ12TSBN (5.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории