Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации LG, модель UT48ACP

Производитель: LG
Размер: 21.26 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


The unit will respond with a beep. 1 Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again. 2 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or Auto. Each time the button is pressed, the fan speed mode is shifted. . Air purifying operation (PLASMA) with cooling, heating or any other operations. 3 Tips for Filter sign LED 1. Filter sign lamp (LED) is ON. 2. If LED indicating filter sign lamp is ON, clean the filter. 3. After cleaning the filter, press the Timer button and button of wired remote controller at the same time for 3 sec. Then filter sign LED is OFF. Operating Instructions Forced Operation Operation procedures when the remote control can't be used. Press the tact switch (Forced operation) for 2 seconds. If you want to stop operation, press again the tact switch. In case the power comes on again after power failure on the Forced Operation mode, the operating conditions are automatically set as follows: During Forced Operation, the initial mode continues. Forced operation (Tact switch) High Speed In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. Heat pump ModelCooling Model Room Temp. . set Temp.-2°C Room Temp. < set Temp.-2°C Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly. Operating mode Cooling Cooling Heating Indoor FAN Speed High set available set available Setting Temperature 22°C set available set available Auto Restart Function 26 Cassette-Type Air Conditioner Owner's Manual 27 ENGLISH Maintenance and Service Maintenance and Service Indoor Unit Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. NOTICE Grille, Case and Remote Control . Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning the indoor unit. NOTICE CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit. It may cause an injury. Remove the Air filters. Take hold of the tab and pull slightly forward to remove the filter. Clean dirt from the air filter using a vacuum cleaner or washing with water. If dirt is conspicuous, wash with a neutral detergent in lukewarm water. If hot water (50°C or more) is used, it may be deformed. After washing with water, dry well in the shade. Do not expose the air filter to direct sunlight or heat from a fire when drying it. Install the air filter. Air Filters The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. Never use any of the followings: • Water hotter than 40°C. Could cause deformation and/or discoloration. • Volatile substances. Could damage the surfaces of the air conditioner. 1 2 3 4 Benzene SCOURING CLBARGER SINNER Air Outlet Air Intake (side, rear) Connecting Wire Drain Hose Connection Pipe Power Wire Air Outlet Air Intake (side, rear) Connecting wire Control cover Anti-biofilter Remote Controller Air Outlet Air Intake Rack Air Filter 28 Cassette-Type Air Conditioner 1 2 Maintenance and Service Purifying filter (Optional) Cleaning The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary. Replacement • Recomended use period : About 2 years Open front panel and remove air filter. Remove air purifying filter. Insert new air purifying filter. After removing the air filters, pull slightly forward to remove the PLASMA filter. Dip the PLASMA filter into the water mixed with neutral detergent, for 20~30 minutes. Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts). Note the cuts of electric discharge lines. Re-install the PLASMA filter to the original position. Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock. Reinsert air filter and close front panel. 1 1 2 3 4 5 2 3 4 Maintenance and Service When the air conditioner is not GOING to be used for a long time. When it is not going to be used for When the air conditioner is to be used again. a long time. 1 1 2 3 2 Operation Tips Operate the air conditioner at the following settings for 2 to 3 hours. • Type of operation: Fan operation mode.(Refer to pag...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории