Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации LG, модель EN 61000-2

Производитель: LG
Размер: 4.73 mb
Название файла: 5c280641-768e-4f6f-9be8-36b59e5b6fa4.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


24°C(75.2°F) 21°C(69.8°F) . Room Temp. < 24°C(75.2°F) Room Temp. < 21°C(69.8°F) Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22°C(71.6°F) 22°C(71.6°F) 23°C(73.4°F) 24°C(75.2°F) Test operation During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep". If you want to stop the operation, re-press the button. Operating Instruction 24 Room Air Conditioner High Speed Auto restart Display Luminosity (Optional) In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode. The Display Luminosity can be adjusted by using the remote control. Press the start/stop button to start the unit. Open the door on the remote control, press the 2ndF button and, press display luminosity button. Display will be dark. Press the button again to set bright display. Auto restart function has set enable as factory default. But customer can set up by following this instruction. To disable function - Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times. To enable function - Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times. NOTICE Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly. Maintenance and Service Owner’s Manual 25 ENGLISH Maintenance And Service Indoor Unit Before performing any maintenance, turn off the main power to the system. Grille, Case, and Remote Control Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning the indoor unit. Air filters The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary. 1. Open the front panel as shown. 2. Pull the filter tab slightly forward to remove the filter. 3. Clean the filter with a vacuum cleaner or warm, soapy water. • If dirt is conspicuous, wash with a solution of detergent in lukewarm water. • If hot water (40°C(104°F) or more) is used, it may be deformed. 4. After washing with water, dry well in the shade. 5. Re-install the air filter. NEO PLASMA filter (Optional) The NEO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary. 1. After removing the air filters, pull slightly forward to remove the NEO PLASMA filter. 2. Clean NEO PLASMA filter with the vacuum cleaner. If it is very dirty, wash it with water. 3. Note the cuts of electric discharge lines. 4. Re-install the NEO PLASMA filter to the original position. TRIPLE DEODORIZER filter (Optional) 1. After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZER filter. 2. Dry in the sunlight for two hours. 3. Re-install the TRIPLE DEODORIZER filter to the original position. NOTICE Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille, it may cause an electric shock. Never use any of the followings: • Water hotter than 40°C(104°F) Could cause deformation and/or discoloration. • Volatile substances Could damage the surfaces of the air conditioner. Gasoline Powder Vertical louver Horizontal louver Air filters Air outlet vent (behind front panel) Air inlet vent Plasma filter Front panel Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Air intake vents Piping Air outlet NOTICE vents Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Common Problems And Solutions Before calling for service (Side) (Rear) If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer. Air conditioner does not operate 1. Ensure that the air conditioner is plugged into a proper outlet. 2. Check the fuse or circuit breaker. 3. Ch...

Эта инструкция также подходит к моделям:
Кондиционеры - EN 61000-3 Norm) (4.73 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории