Производитель: DeLonghi
Размер: 694.62 kb
Название файла: KW85.pdf
|
Фрагмент инструкции
. . .pag. 4 • Mode d’emploi et d’entretien . . . . .pag. 15 • Instrucciones de uso . . . . . . . . . .pag. 28 • Manual de instrucoes . . . . . . . . . .pag. 41 • Istruzioni per l’uso . . . . . . . . . . . .pag. 54 Sylvane LLC 800-934-9194 • Use and maintenance manual . . . .pag. 4 • Mode d’emploi et d’entretien . . . . .pag. 15 • Instrucciones de uso . . . . . . . . . .pag. 28 • Manual de instrucoes . . . . . . . . . .pag. 41 • Istruzioni per l’uso . . . . . . . . . . . .pag. 54 Sylvane LLC 800-934-9194 (text) Sales Inquiries: 800-934-9194 Important safeguards GB/KW85 18-11-2003 14:02 Pagina 2 Important safeguards GB/KW85 18-11-2003 14:02 Pagina 2 • Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many eventualities as possible. Caution and common sense should be used when operating and installing this air conditioner. • This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes. • It is dangerous to alter or modify the unit's characteristics in any way. • The appliance must be installed in line with the relevant national legislation. • Should repairs be necessary, contact the nearest authorized De’Longhi Repair Service Center. Unauthorized De’longhi servicing can be dangerous. • This appliance is to be used by adults only; keep away from children. • In the case that the power cord becomes damaged, this must be replaced only by specialized personnel authorized by the manufacturer. • Always ensure the appliance is grounded. If you have any doubts check with a qualified electrician. •Avoid using extension cords with the unit. • Before cleaning or maintenance operations, always unplug the unit from the outlet. •Do not pull on or place strain on the power cord when moving the appliance. • The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources. • Do not rest hot or heavy objects on the appliance. • Clean the filters at least once a week. •Avoid using heaters near the unit. • The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally. • Before transporting the unit, drain the condensation collecting-tray and tank. After transportation, wait at least 1 hour before switching on the unit. • The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection. SAVE THESE INSTRUCTIONS 2 Introduction GB/KW85 18-11-2003 14:02 Pagina 3 Introduction GB/KW85 18-11-2003 14:02 Pagina 3 The portable air conditioner is a compact unit for regulating air temperature and humidity. Its extremely flexible characteristics make it easy to use at any time and in any room. It can be operated in multiple modes including cooling, dehumidifying and ventilating. The appliance has been designed for domestic use and may be used in the home, office, etc. It must be connected to an outlet with an impedance of less than 0.197 Ohms. If necessary, consult your electricity supply company for information on impedance values. TIPS FOR ENERGY SAVING • Keep blinds and/or curtains and windows closed during the sunniest hours of the day (cooling function). • Keep the filter clean. In normal conditions, the filter should be cleaned about every 2 weeks. The filter eliminates part of the pollutant particles or dust transported in the air. Air quality thus depends on the frequency with which the filter is cleaned. 3 Description GB/KW85 18-11-2003 14:02 Pagina 4 Description GB/KW85 18-11-2003 14:02 Pagina 4 DESCRIPTION OF PARTS Front Control panel Air flow direction fins (right hand – left hand) Air outlet Air flow direction fins (high – low) Handle Water tank Castors Back Top air intake grille for cooling, dehumidifying and ventilating. Hot air outlet Connector for supplementary water tank Bottom air intake grill 4 Control panel GB/KW85 18-11-2003 14:02 Pagina 5 Control panel GB/KW85 18-11-2003 14:02 Pagina 5 All functions of the unit can be controlled from the control panel or the remote control unit (certain models only). TIMER ON/OFFbutton Press this button to activate the timer function (turns the appliance off if already on and vice versa). SET TEMP buttons These buttons can be used to set the required room tem- perature in a range between 17°C (62°F) and 31°C (87°F). The tempera- ture set is increased or reduced by 1°C (33°F). TIMER HOUR button Press this button to set the length of time before the appliance goes off (with the unit on) or comes on (with the unit off). SWING button Press this button to distribute the air flow evenly throughout the room (swing) or in a specific direc- tion (fixed position). FAN SPEED button Press this button to set the speed of the air flow emitted: Max (HIGH), Med (MED), Min (LOW). MODE KEY Press this button to select the various operating modes: air c...