Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации DeLonghi, модель PAC-A130HPE

Производитель: DeLonghi
Размер: 559.36 kb
Название файла: 89c7672d-9e8e-419a-9f72-d9e28b21a28a.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner. • This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes. • It is dangerous to alter or modify the unit's characteristics in any way. • The appliance must be installed in accordance with the relevant national legislation. • Should repairs be necessary, contact the nearest authorized Repair Service Center. Unauthorized servicing can be dangerous. • The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. • In the case that the power cord becomes damaged, this must be repaired only by specialized personnel authorized by the manufacturer in order to protect against fire. • Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts check with a qualified electrician. • We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-prong grounded extension cord, attachment plug and connector, rated 15A, 125V • Before cleaning or maintenance operations, always unplug the unit from the outlet. • Do not pull on or place strain on the power cord when moving the appliance. • The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources. • Do not rest hot or heavy objects on the appliance. • Clean the filters at least once a week. • Avoid using heaters near the unit. • The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally. • Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on. • The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection. • This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes. • WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol. Avoid perforating the refrigerant circuit of the appliance. Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975). SAVE THESE INSTRUCTIONS THIS PRODUCT IS FOR HOUSEHOLD ONLY DESCRIPTION 10 power cable 1 air outlet grille 11 wall flange 2 control panel 12 air exhaust hose 3 remote control receiver 13 window outlet 4 castor wheels 14 castor locks 5 handles 15 remote control 6 filter 16 window bracket with locking pins 7 air intake grille 17 end of season dust cover 8 air exhaust hose housing 18 end of season accessories bag 9 drainage hose 19 extra locking pins for window bracket 4 5 The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed. AIR CONDITIONING WITHOUT INSTALLATION NOTE: Keep the air hoses as short and free of curves as possible to avoid constrictions. FOR OPTIMAL RESULTS SET-UP IN A DOUBLEHUNG WINDOW: 1) Place the bracket in the window sill, extend the bracket fully within the window frame, fix the bracket by using the pin then lower the window onto the bracket. (Should the window bracket be too large for the window. The plastic can be cut with a saw by a qualified professional.) 2) Fit the air exhaust hose in the housing at the back of the appliance. Insert it as shown in figure A. 3) Connect the window outlet to the other end of the exhaust hose. 13 4) Insert the window outlet end of the exhaust hose into the slot of the window bracket (fig. B). Setting up your portable air-conditioner TO AVOID DAMAGE TO THE UNIT: NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the compressor to ensure proper function. Without allowing the unit this time (6-24 hours) The unit may function for only a short time, and then the compressor will break down from lack of oil). If it becomes necessary, the power cable must be replaced by a qualified professional only. A C Other set-up methods: • Thanks to the locking pins, it’s possible to use the window bracket also for sliding...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории