Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Mitsubishi Electronics, модель LOSSNAY LGH-50RX4-E

Производитель: Mitsubishi Electronics
Размер: 1.4 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If flammable gases should leak, do not turn the Lossnay’s switch on or off. (Failure to heed this warning may cause the electrical contacts to generate sparks which may result in an explosion.) Open windows to ventilate. . Do not poke your fingers or sticks into the air intake and outlet while the product is operating. (Failure to heed this warning may result in injury.) Do not touch . Gloves should be worn when doing the installation and maintenance work. (Failure to heed this warning may result in injury.) Instructions must be . Be sure that the power board circuit breaker is in the OFF position and is securely locked by lock and key before proceeding with followed maintenance work. (Failure to heed this warning may result in electrical shock or injury.) . In the event of trouble (smell of burning, etc.), shut down operation, set the power board circuit breaker to its OFF position and consult your dealer. (Continued operation without remedying the trouble may result in electrical shock, fire, etc.) Names of the parts Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4 1 Maintenance cover 3 Lossnay core holder 1 Maintenance cover 3 Lossnay core holder 2 Control box 4 Air supply fan 5 Lossnay core 7 Air filter 5 6 Air exhaust fan 8 Damper plate 6 Air exhaust fan 8 Damper plate 2Control box 7Air filterLossnay core 4Air supply fan English Operation 1. For connection of a remote controller (PZ-41SLB-E) If the Lossnay’s operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out the appropriate operation in accordance with the following table. Also, please see the installation and user’s manual for the remote controller (PZ-41SLB-E). Example of System Operation Function Lossnay Power Supply Remote Controller (Optional parts) (PZ-41SLB-E) Run using the remote controller. • If 2 remote controllers are used, the last controller to be used has priority. (Last Command) Lossnay Power Supply External device Remote Controller (Optional parts) (PZ-41SLB-E) Power Supply Operation switch for the external device If an external device is connected the “On/Off” function of this device will also control the Lossnay operation. • If you would like to turn ON the Lossnay alone while the external device is OFF, operate it by the Lossnay remote controller. Lossnay Power Supply External device Power Supply Operation switch for the external device • The fan speed is on “High”. • The ventilation mode is “Ventilation Mode Auto Select”. 2. For connection of a Lossnay remote controller (PZ-52SF-E), Mitsubishi Electric Air-Conditioner Network System (MELANS) or City Multi. This is to be incorporated and used in the Mitsubishi Electric Air- Conditioner Network System. This is interlocked with the City Multi and operated by it. If the Lossnay remote controller (PZ-52SF-E) is used, the Lossnay may be operated independently if conne...

Эта инструкция также подходит к моделям:
Кондиционеры - LOSSNAY LGH-100RX4-E (1.4 mb)
Кондиционеры - LOSSNAY LGH-150RX4-E (1.4 mb)
Кондиционеры - LOSSNAY LGH-15RX4-E (1.4 mb)
Кондиционеры - LOSSNAY LGH-200RX4-E (1.4 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории