|
Фрагмент инструкции
This could result in electrical shock. : CAUTION: 1) Office Pro 12 model ONLY : The AC outlet (115 VAC Single Phase, 60Hz) needs to be rated at 15A or higher. Do not share the outlet with any other instrument or equipment. 2) Office Pro 18 model ONLY : The AC outlet (115 VAC single Phase, 60Hz) needs to be rated at 20A or higher. Do not share the outlet with any other instrument or equipment. 3) Office Pro 24 model ONLY : The AC outlet (208/230 VAC single phase, 60Hz) needs to be rated at 20A or higher. Do not share the outlet with any other instrument or equipment. NOTE : 1) Make sure the AC outlet is free of dirt, dust, oil, or any other foreign matter. 2) The Office Pro 12 model is equipped with a UL approved LCDI cord and an approved NEMA plug configuration (5-15). The appropriate outlet must be used for this plug type. 3) The Office Pro 18 model is equipped with a UL approved LCDI cord and an approved NEMA plug configuration (5-20). The appropriate outlet must be used for this plug type. 4) The Office Pro 24 model is equipped with a UL approved LCDI cord and an approved NEMA plug configuration(6-20). The appropriate outlet must be used for this plug type. 10 INSTALLATION (cont.) Warning Signal Connection (Output Signal terminal L+ and L-). The controller is equipped with a warning signal output relay type (Form C, normal open dry contact) which can be used to monitor the failure condition. Relay contactor (not connector) is closed when the following condition has occurred : a. Tank Full b. Temperature sensor fails c. High pressure switch error (model OP24 only) The relay output contactor is rated 2A at 30VDC or 2A at 30VAC (resistive load) and it is compatible with various warning devices such as alarm speaker, light indicators, etc. Connecting Warning Signal From Controller .. 1) Remove service panel from the rear of the unit. 2) Push out the back cap from inside. (In case of hand to remove, please push inner latches of the cap one-by-one) 3) Use recommended warning signal wire size from 16AWG to 26AWG for a solid wire, or 16AWG to 22AWG for a stranded wire with ring terminal for #6 stud size. 4) Connect warning device to terminal L+ and L-according to its polarities. Fire Alarm Control Panel Connection (Input Signal terminal E+ and E-) .. The controller is equipped with a normal open input signal, which can be connected directly from the fire alarm control panel. When receiving the signal from the fire alarm control panel, the unit will turn off and will not turn back until it has been RESET. Connecting Fire Alarm Control Panel to Controller .. 1) Remove service panel from the rear of the unit. 2) Squeeze the inner latches and push out the black cap from inside the panel (See drowing of Cap and inner latch shapes ) 3) Use recommended warning signal wire size from 16AWG to 26AWG for a solid wire, or 16AWG to 22AWG for a stranded wire with ring terminal for #6 stud size. 4) Connect warning device to terminal E+ and E-according to its polarities. ..This function is not available in OP12 model Latch Cap } } Input Signal Terminals } } Output Signal Terminals 11 INSTALLATION (cont.) LCDI Power Cord Instruction ! ! WARNING The LCDI device is non-serviceable device. Attempting to open the device may expose the user to hazardous of electric shock, and could void warranties of this product. Manufacturer’s reliability is limited to the replacement of the device. CAUTION 1. Read the attention print on the device for proper use and handling of this device. 2. This device is used for monitoring leakage current. 3. Do not immerse in water. 4. This device must only be plugged into an appropriate wall outlet. Do not use on extension cords or adapter. Do not remove ground prong. 5. In the event that this device trips, the cause of malfunction should be corrected first before further use. 6. Using the device beyond recommended voltage poses risk to users. 7. Conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded, and they are periodically examined the cord for any damage. Do not use this product in the event the shields become exposed. 8. Do not push test and/or reset buttons in a short period. PROCEDURE Test device once when AC is installed to assure proper operation. 1. Plug into grounded power receptacle. 2. If light is not on, press reset button once. Light should turn on. 3. Press test button once, light must turn off. 4. Press reset button once again for use. Light should turn on. 5. If test fails, do not use.
Кондиционеры - MOVINCOOL OFFICE PRO 18 (1.08 mb)
Кондиционеры - MOVINCOOL OFFICE PRO 24 (1.08 mb)