|
Фрагмент инструкции
If dust and/or dirt are present, wipe off with a clean, dry cloth. . Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. . Clean the air filters. . Empty all water from the drain tank. 16 TROUBLESHOOTING Self-Diagnostic Codes Self-Diagnostic Codes will be displayed on the Control Board under the following conditions: Code Condition dF When the evaporator thermistor disengages the compressor. FL When the drain tank switch shuts off the unit (FULL TANK LED flashes). AS When unit disengages the compressor while the condensate pump is discharging water. HP When the high pressure switch disengages the compressor. Check the following points before calling a qualified technician. SET TEMP FAN ON/OFF COOL ON/OFF Classic Plus SYMPTOM POSSIBLE CAUSE REMEDY Unit does not operate . Ground fault breaker blown . Drain tank is full (FULL TANK LED will be flashing) Reset breaker Empty the drain tank Insufficient cooling . Dirty/blocked air filters . Air inlet/outlet blocked . Improper temperature setting Clean air filters Clear air inlet/outlet Set to desired position If symptoms persist after the above actions have been taken, turn the unit off, disconnect the power cord plug and contact your MovinCool reseller. 17 TECHNICAL SPECIFICATIONS ITEM/FEATURES MODEL Classic Plus 14 Classic Plus 26 Rating Conditions dry bulb 95oF (35 oC) 95oF (35 oC) wet bulb 83oF (28.3 oC) 83oF (28.3 oC) humidity (60%) (60%) Specifications power frequency 60Hz 60Hz line voltage, single phase 115 V 208/230V power consumption 1.41 Kw 3.37/3.24 Kw current consumption 12.3 Amps 16.8/14.6 Amps power factor 95% 97% starting current 32A 62A power cord 14 (3-core) AWG 12 (3-core) AWG Cooling Unit cooling capability 3,300 Kcal/hr 13,200 BTU/hr 6,500 Kcal/hr 26,000 Btu/hr cooling system direct expansion direct expansion Blower type of fan centrifugal fan centrifugal fan air volume: Evaporator (high speed) 470 ft3/min;798 m3/h 708 ft3/min; 1202 m3/h Condenser (high speed) 882 ft3/min;1498 m3/h 1680 ft3/min; 2853 m3/h motor output: (high speed) 0.24 Kw .59/.63 Kw (low speed) 0.19 Kw .54/.56 Kw Compressor type output refrigerant type refrigerant capacity rotary 0.8 Kw R-22 1.50 lbs (0.68 kg) hermetic scroll 1.6kw R-22 1.87 lbs. (0.85 kg) Safety Devices compressor overload protector included included fan motor protector included included anti-freezing thermistor included included full drain tank switch included included automatic restart (power interruption) included included compressor time delay program included included Dimensions & Weight W x D x H (in.) 19.4 x 26.5 x 41.5 19.4 x 28.7 x 47.2 W x D x H (mm) 492 x 673 x 1054 492 x 730 x 1200 weight (lbs/kg) 165/75 235/107 Operating Conditions inlet air (relative humidity) 113oF (45 oC), < 50% 70oF (21.1 oC), > 50% 113oF (45 oC), < 50% 70oF (21.1 oC), > 50% Control Device temperature control two speed fan included included included included 18 LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOL Products only to the extent stated in its official written warranties. Unless otherwise specifically provided in writing by DENSO, DENSO warrants to enduser that the Products shall be free of defects in materials or workmanship and will function in accordance with DENSO's published specifications under ordinary intended use and service for a period of twelve (12) months after delivery to the enduser; provided, however, in the case of the compressor element of the Products such warranty shall be for a period of thirty six (36) months after delivery to the end-user. DENSO shall, at its sole option, repair or replace any defective Product covered by this warranty. Such remedy shall be end-user's sole remedy with respect to any particular defect in the Products. This warranty does not cover defects or malfunctions which result from causes beyond DENSO's control, including, without limitation, (i) unusual physical or electrical stress; (ii) accident, neglect, abuse, misuse or other abnormal use; (iii) failure to perform routine maintenance in accordance with DENSO'S recommended procedures; (iv) normal wear and tear; (v) repairs or attempted repairs by an unauthorized person; (vi) modifications or alterations to the Products; (vii) use with supplies or devices not supplied or approved by DENSO; or (viii) improper servicing. This warranty shall extend only to the original end-user and shall be void if any labels or other identifying marks permanently affixed to Products when shipped by DENSO are removed, altered, defaced or obliterated. The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of an...
Эта инструкция также подходит к моделям:Кондиционеры - CLASSIC PLUS 14 (2.54 mb)