Производитель: Kenmore
Размер: 1.07 mb
Название файла:
|
Фрагмент инструкции
AVOID sharp metal fins on front and rear coils. • Make sure air conditioner does notfall dudng installation. Required Tools and Equipment • Tight-fitting gloves • Standard screwddver • Phillips screwdriver • Pliers • Sharp knife • Carpenters' level • 3/8"open-end wrench or adjustable wrench • 1/4"hex socket and ratchet • Tape measure • Electdc drill • 1/8"drill bit Installation Kit Parts Window installation kit contains the following parts. Be sure all parts are included before starting installation. If parts are missing, contact Sears. NOTE: Parts are listed in the order used and are illustrated in Figure 3. Item # Description Quantity A Window sill gasket (." x .") 40" B 1." adjusting foot 1 C Support bracket 1 D %" hex-head screw 3 E Sash bracket 1 F %" Phillips screw 3 G Window seal stdp (3A"x 1.") 40" Figure 3. Window Installation Kit Parts F Installation Installation Requirements See Figure 4. Inspect window track, sash, and sill. Ensure window will bear weight of air conditioner for extended period of time. Measure width of window opening to besure air conditioner will fit.Air conditioner is designed for windows 22." to 40" wide. Ensure lower left inside corner of window is within 6' of an appropriate electrical outlet. NOTE: Installation kit is designed for most double-hung windows that do not have storm windows installed. If storm window is installed, or if installation is in a mobile home, window sill may need modification. See procedure for Storm Window Modification or for Mobile Home Window Modification. Figure 4. Typical Double-Hung Window 1. Window frame 2. Window track 3. Outdoor sash 4. Indoor sash 5. Window sill(indoor) t\ j / / _J / J j' /s I 4 // / F, 5 Storm Window Modification See Figure 5. if storm window frame does not allow adequate clearance (1' required), remove frame or create clearance by adding wood strip at least 1." wide and 1" thick along entire width of sill Fasten wood strip to sill with three countersunk wood screws (not provided) to ensure smooth surface for mounting kit. Next, center 6" x 41A"wood block on outside of window sill between sides of window frame. Wood block must be same thickness as wood strip installed on indoor sill. Attach block to outside sill using 3 countersunk screws. Mounting kitcan now be installed. Figure 5. Window Frame Modification 1. Indoorsash (shown open) 2. Wood strip (1I/="wide) 3. Indoor sill 4. Wood block 5. Storm windowframe 6. Atleast1"clearancebetweentopofwindowsilland top of storm window frame 7. Outdoor sash 2 Mobile Home Window Modification See Figure 6. Mobile home window modification requires adding wood strip at least 1." wide along entire width of window sill.Thickness of wood stripshould match height of front lip of window frame. Fasten wood strip to sill with 3 countersunk wood screws (not provided) to ensure smooth surface for mounting kit. Mounting kit can now be installed. Installation Figure 6. Modifying Mobile Home Window 1. Indoor sash (shown open) 2. Wood strip (1." wide) 3. Window sill 4. Window frame 2 4 Installation Procedure 1. See Figure 7. Raise indoor sash and measure sash width, including portion in window track. Cut window sill gasket (installation Kit Item A) to length of indoor sash and apply to rear of indoor window sill.To apply gasket, peel back about 2" of paper covedng gasket adhesive, and carefully press exposed adhesive to one end of window sill. Slowly peel away remaining paper cover from gasket adhesive, and press gasket to sill as paper is pulled away. If window has been modified for installed storm window, apply gasket to wood strip added to sill. For mobile home installation, apply gasket to outdoor side of window frame bottom lip. Figure 7. Applying Window Sill Gasket 1. Indoor sash 2. Indoor sill 3. Paper covering gasket adhesive 4. Gasket 4 2. See Figure 8. Thread adjusting foot (Item B) through bottom of support bracket (Item C). Measure width of window and mark center point of outside sill. Figure 8. Support Bracket Assembly 1. Support bracket 2. Adjusting foot / I 2 3. See Figure 9. Center support bracket on outside sill, 1_/16"from rear edge of indoor sill. Secure bracket to outdoor sill with 2 hex-head screws (Item D), Figure 9. Installing Support Bracket 1. 13/16"gap 2. Center of window 3. Hex-head screws 4. Bubblelevel 4 \ 2 \ / Installation . See Figure 9. Place bubble level between indoor silt . See Figure 11. Position sash bracket (Item E) on top and outdoor end of support bracket. Turn adjusting of indoorsash, flush with outdoor sash. Secure foot on support until level tilts . bubble toward bracket to outside sash using %" hex-head screw outdoor side. (Item D).DrillI/e"pilotholetomakescrew easierto install. NOTE: Adjustingsupport bracket for . bubble outdoor slope should result in ." backward slope on installed air conditioner, required for proper water I CAUTION I (condensate) drainage. To prevent damage to window locking or lifting 5. See Figure 10. Place air conditioner inwindow, m...
Эта инструкция также подходит к моделям:Кондиционеры - 70089 (1.07 mb)
Кондиционеры - 78079 (1.07 mb)
Кондиционеры - 78189 (1.07 mb)